Blue Light Total Dose Nonvolatile Sensor Using Al-SOHOS Capacitor Device †

Department of Opto-Electronic System Engineering, Minghsin University of Science and Technology, Xinxing Road 1, Xinfeng 30401, Taiwan
Presented at the 5th International Electronic Conference on Sensors and Applications, 15–30 November 2018; Available online: https://ecsa-5.sciforum.net.
Proceedings 2019, 4(1), 45; https://doi.org/10.3390/ecsa-5-05736
Published: 14 November 2018
(This article belongs to the Proceedings of 5th International Electronic Conference on Sensors and Applications)

Abstract

:
The Al doped silicon–silicon oxide–hafnium oxide–silicon oxide–silicon capacitor device (Al-SOHOS) could be a candidate for blue light (BL) radiation total dose (TD) nonvolatile sensor. The BL radiation induces a significant increase in the threshold voltage VT of the Al-SOHOS capacitor, with the change in VT of the Al-SOHOS capacitor also having a correlation to BL TD. The experimental results indicate that the BL radiation-induced increase in VT of the Al-SOHOS capacitor under 10-V gate positive bias stress (PVS) is nearly 2 V after a BL TD of 100 mW·s/cm2 irradiation. Moreover, the VT retention loss of the nonvolatile Al-SOHOS capacitor device after 10 years of retention is below 15%. The BL TD data can be permanently stored and accumulated in the non-volatile Al-SOHOS capacitor device. The Al-SOHOS capacitor device in this study has demonstrated the feasibility of non-volatile BL TD radiation sensing.

1. Introduction

The measurement of blue light (BL) irradiation total dose (TD) is very important in various BL radiation applications, such as biochemical technology and medical technology. The semiconductor dosimeters offer many advantages as they have very small dose-sensing areas and their dose sensitivity can be high in a small constrained space. A silicon–silicon dioxide–hafnium oxide–silicon dioxide–silicon (SOHOS) capacitor device has been shown to be suitable for nonvolatile UV irradiation TD sensor applications [1,2,3,4]. UV irradiation induces a significant increase in the threshold voltage VT of the SOHOS capacitor device and this UV-induced increase in VT of the SOHOS capacitor has a strong correlation to UV TD. Moreover, VT retention of the SOHOS capacitor device has good reliability even after 10 years of retention. The aluminate-doped silicon–silicon oxide–hafnium oxide–silicon oxide–silicon capacitor device (Al-SOHOS) was proposed in this study. The BL radiation-induced charging effect and charge-retention reliability of the Al-SOHOS capacitor devices were significantly improved. Figure 1a shows the cross-sectional view of the SOHOS capacitor devices. Figure 1b shows the charge generation and trapping states of the gate dielectric in the Al-SOHOS capacitor device after BL irradiation.

2. Experiments

The Al-SOHOS capacitor devices were prepared for this study. To manipulate the radiation-induced charging effects in the Al-SOHOS capacitor, Al-SOHOS capacitor devices were prepared. SOHOS capacitor structures were fabricated on a p-type Si <100> substrate. We used thermal SiO2 for the tunneling oxide, CVD SiO2 for the blocking oxide of the gate dielectric and low-pressure chemical vapor deposition (LPCVD) poly silicon for the gate material. Furthermore, hafnium oxide (HfO2) films were deposited as the charge-trapping layers, which used a Hf(tert-butoxy)2(mmp)2 precursor in a metal organic chemical vapor deposition (MOCVD) system that was run at approximately 400–550 °C. Al doped HfO2 films were deposited as the charge-trapping layers, which used Hf (tert-butoxy)2(mmp)2 and aluminum isopropoxide precursors in a metal organic chemical vapor deposition (MOCVD) system that was run at approximately 400–550 °C. After BL data writing, VT was measured at room temperature using a HP4156A parameter analyzer. The experimental results of gate capacitance applied at various gate voltages (CG-VG) were obtained by a computer-controlled HP4284 parameter analyzer and the CG-VG curves were measured by sweeping VG at room temperature.

3. Results and Discussion

3.1. Radiation-Induced VT Shift in Al-SOHOS after BL Irradiation

Figure 2a shows a CG-VG curve for a Al-SOHOS capacitor device before BL irradiation. Figure 2b shows a CG-VG curve for a Al-SOHOS capacitor device after 100 mW·s/cm2 TD BL irradiation under PVS (VG = 10 V). As illustrated in Figure 2b, the CG-VG curve of Al-SOHOS capacitor shifted to the right after the BL total dose (TD) was increased to 100 mW·s/cm2 irradiation under the PVS gate with a VG of 10 V. This indicates that a BL TD of 100 mW·s/cm2 irradiation induces an increase in VT (about 2 V) of the Al-SOHOS capacitor under the PVS gate with a VG of 10 V. The finding of this positive VT shift is in agreement with previous studies [1,4]. When comparing the Al-SOHOS with the F-SOHOS, the BL radiation-induced charging effect of Al-SOHOS were significantly improved [4].
The increase in VT was plotted against the BL TD for the Al-SOHOS capacitors under a PVS of 10 V and 0 V as shown in Figure 3a,b, respectively. The increase in VT is shown in Figure 3a as a function of BL TD for the Al-SOHOS capacitors device under a PVS of 10 V. The increase in VT of the Al-SOHOS can be correlated to the BL TD increase. However, there was a insignificant increase in VT increase under a PVS of 0 V as shown in Figure 3b. These experimental results in this study are in agreement with previous studies [1].

3.2. VT Stability vs. Retention Time

VT vs. retention time curves for an Al-SOHOS capacitor device before and after BL of 100 mW·s/cm2 irradiation under a PVS of 10 V are shown in Figure 4a,b, respectively. As illustrated in Figure 4a, the increase in VT with time for the pre-BL-irradiated Al-SOHOS capacitor device is a result of negative charges that naturally tunnels into the HfO2 trapping layer of the Al-SOHOS device before BL irradiation. As shown in Figure 4b, the decrease in the VT with time for the post-BL-irradiated Al-SOHOS capacitor device is a result of BL radiation-induced negative charges tunneling out from the HfO2 trapping layer. Moreover, the VT-retention loss of the nonvolatile Al-SOHOS capacitor device after 10 years of retention is below 15%.

4. Conclusions

As shown in the experimental data, the increase in VT of the Al-SOHOS capacitor was nearly 2 V after 100 mW·s/cm2 BL TD irradiation under a PVS gate with a VG of 10 V. Moreover, the Al-SOHOS devices showed better BL-induced charge-retention reliability. The 100 mW·s/cm2 BL-induced charge-retention loss of the nonvolatile Al-SOHOS capacitor after 10 years of retention was below 15%. The Al-SOHOS capacitor device in this study has demonstrated the feasibility of non-volatile BL TD radiation sensing.

Acknowledgments

The author thanks the National Nano Device Laboratories (NDL), National Tsing Hua University (NTHU), and National Chiao Tung University (NCTU) for providing the instruments for wafer fabrication and testing. This study was funded in part by the National Science Council (NSC).

References

  1. Hsieh, W.C.; Lee, H.D.; Jong, F.C.; Wu, S.C. UV Nonvolatile Sensor by Using SONOS Capacitor Device. In Proceedings of the 2013 6th IEEE International Conference on Advanced Infocomm Technology (ICAIT), Hsinchu, Taiwan, 6–9 July 2013. [Google Scholar]
  2. Hsieh, W.C.; Lee, H.D.; Jong, F.C.; Wu, S.C. An Performance Improvement of Total Ionization Dose Radiation Sensor Devices Using Fluorine-Treated MOHOS. Sensors 2016, 16, 450. [Google Scholar] [CrossRef] [PubMed]
  3. Wu, W.C.; Lai, C.S.; Wang, T.M.; Wang, J.C.; Hsu, C.W.; Ma, M.W.; Lo, W.C.; Chao, T.S. Carrier Transportation Mechanism of the TaN/HfO2/IL/Si Structure with Silicon Surface Fluorine Implantation. IEEE Trans. Electron. Devices 2008, 55, 1639–1646. [Google Scholar] [CrossRef]
  4. Hsieh, W.C. UV Total Dose Nonvolatile Sensor Using Fluorine-Treated SOHOS Capacitor Device. In Proceedings of the 5th International Electronic Conference on Sensors and Applications (ECSA4), Basel, Switzerland, 14 November 2017. [Google Scholar]
Figure 1. (a) Cross-sectional view of an SOHOS capacitor device; and (b) Charge generation and trapping in the Al-SOHOS capacitor after BL irradiation.
Figure 1. (a) Cross-sectional view of an SOHOS capacitor device; and (b) Charge generation and trapping in the Al-SOHOS capacitor after BL irradiation.
Proceedings 04 00045 g001
Figure 2. This CG–VG curve for an Al-SOHOS capacitor device under a PVS with a VG of 10 V (a) before BL irradiation; and (b) after a BL TD of 100 mW·s/cm2 irradiation.
Figure 2. This CG–VG curve for an Al-SOHOS capacitor device under a PVS with a VG of 10 V (a) before BL irradiation; and (b) after a BL TD of 100 mW·s/cm2 irradiation.
Proceedings 04 00045 g002
Figure 3. The dependence of the increase in VT on BL TD for an Al-SOHOS (a) under PVS of 10 V; and (b) under PVS of 0 V.
Figure 3. The dependence of the increase in VT on BL TD for an Al-SOHOS (a) under PVS of 10 V; and (b) under PVS of 0 V.
Proceedings 04 00045 g003
Figure 4. Figure 4. VT vs. retention time for an Al-SOHOS device: (a) before BL irradiation; and (b) after BL of 100 mW·s/cm2 irradiation under a PVS gate of 10 V.
Figure 4. Figure 4. VT vs. retention time for an Al-SOHOS device: (a) before BL irradiation; and (b) after BL of 100 mW·s/cm2 irradiation under a PVS gate of 10 V.
Proceedings 04 00045 g004

Share and Cite

MDPI and ACS Style

Hsieh, W.-C. Blue Light Total Dose Nonvolatile Sensor Using Al-SOHOS Capacitor Device. Proceedings 2019, 4, 45. https://doi.org/10.3390/ecsa-5-05736

AMA Style

Hsieh W-C. Blue Light Total Dose Nonvolatile Sensor Using Al-SOHOS Capacitor Device. Proceedings. 2019; 4(1):45. https://doi.org/10.3390/ecsa-5-05736

Chicago/Turabian Style

Hsieh, Wen-Ching. 2019. "Blue Light Total Dose Nonvolatile Sensor Using Al-SOHOS Capacitor Device" Proceedings 4, no. 1: 45. https://doi.org/10.3390/ecsa-5-05736

Article Metrics

Back to TopTop