Review

Breaking Barriers: Exploring Neurotransmitters through In Vivo vs. In Vitro Rivalry

by
Gabriel Philippe Lachance
1,
Dominic Gauvreau
1,
Élodie Boisselier
2,
Mounir Boukadoum
3 and
Amine Miled
1,*
1
Department Electrical Engineering, Université Laval, Québec, QC G1V 0A6, Canada
2
Department Ophthalmology and Otolaryngology—Head and Neck Surgery, Université Laval, Québec, QC G1V 0A6, Canada
3
Department Computer Science, Université du Québec à Montréal, Montréal, QC H2L 2C4, Canada
*
Author to whom correspondence should be addressed.
Sensors 2024, 24(2), 647; https://doi.org/10.3390/s24020647
Submission received: 29 November 2023 / Revised: 11 January 2024 / Accepted: 16 January 2024 / Published: 19 January 2024

Abstract

:
Neurotransmitter analysis plays a pivotal role in diagnosing and managing neurodegenerative diseases, often characterized by disturbances in neurotransmitter systems. However, prevailing methods for quantifying neurotransmitters involve invasive procedures or require bulky imaging equipment, therefore restricting accessibility and posing potential risks to patients. The innovation of compact, in vivo instruments for neurotransmission analysis holds the potential to reshape disease management. This innovation can facilitate non-invasive and uninterrupted monitoring of neurotransmitter levels and their activity. Recent strides in microfabrication have led to the emergence of diminutive instruments that also find applicability in in vitro investigations. By harnessing the synergistic potential of microfluidics, micro-optics, and microelectronics, this nascent realm of research holds substantial promise. This review offers an overarching view of the current neurotransmitter sensing techniques, the advances towards in vitro microsensors tailored for monitoring neurotransmission, and the state-of-the-art fabrication techniques that can be used to fabricate those microsensors.

1. Introduction

Neurotransmitters have a crucial role in the functioning of the nervous system, which oversees the control and coordination of all bodily activities. Neurons synthesize neurotransmitters and store them in vesicles located at the ends of their axons. An action potential traveling down the axon reaches the axon terminal, prompting the release of the neurotransmitter into the synapse. Subsequently, the neurotransmitter diffuses across the synapse and binds to receptors on the postsynaptic neuron. This interaction can either enhance or inhibit the activity of the postsynaptic neuron.
Within the existing body of literature, numerous chemical compounds have been identified to function as neurotransmitters. Although numerous neurotransmitters have been identified, only a select subset is prominently involved in most well-known neuropathies, including Alzheimer’s, Parkinson’s, and Huntington’s diseases. These disorders are characterized by the deterioration of neuronal structure and function, which in turn influences specific neurotransmitter levels and the functioning of neurotransmitter systems.The precise identification and quantification of neurotransmitters are of great importance in neuroscience due to their crucial roles in the central nervous system and the severity of disorders associated with their dysfunctions.
Given the substantial differences in neurotransmitter compositions, standard detection techniques are often optimized for particular compounds, typically based on electrochemical or imaging approaches depending on the specific neurotransmitter under examination.
Numerous articles discussed the significance of neurotransmitter detection and described conventional approaches. These include well-established methods such as microdialysis and analytical chemistry-based techniques, as well as more recent research methods like optical and in vivo electrochemical sensing, which offer faster responses, higher sensitivity, selectivity, and instrument miniaturization. Classical techniques like microdialysis are established for clinical neurotransmitter sampling, while the use of newer techniques like optical sensing methods with nanomaterials is limited due to their less mature technology. The development of small, portable instruments for neurotransmission analysis has the potential to revolutionize the diagnosis and management of neurodegenerative diseases. These devices would be less invasive and enable continuous monitoring of neurotransmitter levels and activity in real time, providing earlier detection of disease progression and more targeted treatment interventions.
Recent advances in the field of microfabrication have led to the development of micro-instruments that could be used to study the dynamics of neurotransmitters in vivo. These instruments are based on microfluidics, micro-optics, and microelectronics and allow for the detection of neurotransmitters in a compact and easy-to-use manner. These micro-instruments offer several advantages over traditional methods of neurotransmitter detection. They are small, lightweight, and easy to use, making them suitable for use in clinical and laboratory settings. They also provide high temporal and spatial resolution, enabling real-time monitoring of neurotransmitter levels and activity with high sensitivity and specificity. Additionally, they are cost-effective and could potentially be used as a point-of-care diagnostic tool.
Micro-instruments for neurotransmission analysis based on micro-incubators for neurons could also be used for in vitro studies, providing an alternative to the more complex ex vivo and in vivo studies. In vitro studies are essential for understanding the fundamental mechanisms of neurotransmitter release, uptake, and metabolism. The micro-instruments can be used to measure neurotransmitter concentrations in microscale environments, allowing for the study of neurotransmitter dynamics in a controlled environment, which would also be more accessible than animal testing.
Overall, micro-instruments for neurotransmission analysis hold significant promise for the diagnosis and management of neurodegenerative diseases. They offer a non-invasive and continuous monitoring solution that could enable earlier detection of disease progression and more targeted treatment interventions. The development of these instruments is an exciting area of research, and further advances in microfabrication technology will undoubtedly lead to even more sophisticated and versatile devices for studying the dynamics of neurotransmitters in vivo and in vitro.
In this review, we introduce the current techniques used for the monitoring of neurotransmitters in vivo in Section 2. In Section 3, we introduce different advances that are being done in the fields of Lab-on-Chip (LoC) and Organ-on-Chip (OoC) that would change the way biochemistry research is being done. We also explore why these changes are required with the ever-changing politics and regulations in place that affect the world of research. We also highlight the techniques from Section 2 that would be suited to be integrated with those artificial organs to emulate the analysis that is being done in vivo. Finally, in Section 4, we introduce different novel microfabrication techniques and their usage for the fabrication of micro-incubators for in vivo neurotransmitter detection. This review is also intended to provide an overview of novel technologies that can be implemented in the field of neuroscience, technologies that might not have been correlated otherwise. We conclude this review in Section 5.

2. In Vivo Neurotransmitter Sensing Techniques

Within the current literature, a diverse array of methods exists for detecting neurotransmitters, each bearing distinct merits and limitations. These methodologies can be broadly categorized into five principal groups: nuclear, optical, electrochemical, sampling, and other techniques. Nuclear techniques involve the deployment of radioactive tracers, whereas optical techniques harness light to gauge neurotransmitter levels. Electrochemical techniques employ electrodes to quantify the electrical or chemical signals stemming from neurotransmitter release. Microdialysis entails the collection of extracellular fluid for subsequent analysis. Additional techniques encompass mass spectrometry, biosensors, and immunoassays. The selection of a specific technique hinges on the nature of the neurotransmitter under scrutiny and the intended purpose of the analysis. A comprehensive exploration of these distinct techniques has been undertaken by numerous authors in the past [1,2,3,4,5,6,7,8,9,10,11].
These reviews have primarily aimed to detail the range of techniques employed for detecting and analyzing specific neurotransmitters within the context of neurotransmission. Furthermore, they have engaged in comparative analyses, spotlighting the respective advantages and drawbacks of each technique.
In the scope of this review, we delve into the most recent advancements in conventionally reviewed neurotransmitter sensing techniques (between 2019 and 2023 inclusively). Additionally, we probe deeper into the realm of optics, exploring the potential for their miniaturization. This examination is particularly pertinent in light of a shifting research focus, wherein in vitro analysis takes precedence over in vivo analysis.

2.1. Medical Imaging Technique

Nuclear tomography neuroimaging techniques, namely positron emission tomography (PET) and Single-Photon Emission Computed Tomography (SPECT), offer insights into neurotransmitter release within the human brain. PET involves administering a radioactive substance that emits positrons into the patient’s bloodstream. The annihilation of a positron generates two gamma photons traveling in opposing directions, which a PET scanner detects, producing an image of radiotracer distribution. Conversely, SPECT entails introducing a radioactive agent emitting gamma radiation, selectively binding to specific tissues, thus highlighting distinct biological processes. Employing a gamma camera rotated around the patient, SPECT generates an image of the radiopharmaceutical distribution. Comprising a collimator to determine photon angles and gamma-ray detectors, the camera, along with a tomographic reconstruction algorithm, derives a three-dimensional map of radioactive activity.
Both PET and SPECT rely on competition between endogenous neurotransmitters and radiotracers to target molecules, scanning these radiotracers to construct images. PET boasts superior spatial resolution by employing two photons for pinpointing each point of interest. In contrast, SPECT emits a single gamma photon directly from the radioisotope atom, allowing heavier isotopes to label other molecules. However, PET surpasses SPECT in sensitivity, albeit at a higher cost, therefore enhancing spatial resolution.
Within the literature, PET has been utilized for imaging in the context of analyzing neurotransmission alterations in neurodegenerative disorders like Alzheimer’s disease [12,13]. Moreover, it has found applications in quantifying neurotransmitter dynamics [14] and exploring other pathologies [15].
In summary, both PET and SPECT are nuclear tomography neuroimaging techniques enabling neurotransmitter visualization within the human brain. Although PET offers superior spatial resolution, SPECT presents a cost-effective option that can make use of heavier isotopes for labeling. However, both techniques are constrained by developmental difficulties. Nonetheless, their sensitivity, selectivity, and spatial precision would render them a valuable goal in the pursuit of miniaturized LoC in vitro neurotransmitter sensing if there was a realistic way of reducing the size of such machines.
An approach adjacent to nuclear medicine that is amenable to conjoint use with PET is magnetic resonance spectroscopy (MRS). MRS operates on the foundation of magnetic resonance imaging (MRI), capturing radiofrequency signals emitted by diverse atoms in the brain. For neurotransmitter concentration assessment, researchers employ a specialized MRS technique known as proton magnetic resonance spectroscopy (1H-MRS). This technique exploits the distinct magnetic properties of protons, which vary based on their chemical environment.
MRS does not replace MRI techniques entirely; rather, it can complement other methods, such as PET. When paired with PET, for instance, MRS proves a potent approach for in vivo neurotransmitter analysis. In fact, the integration of MRI with PET (or analogous nuclear imaging techniques) has shown promise in gathering underlying neurotransmitter information [16,17].
On its own, MRS has demonstrated considerable efficacy in in vivo neurotransmission analysis [18,19,20,21,22]. However, owing to its foundation in MRI technologies, applying MRS to in vitro neurotransmitter detection is constrained by the technique’s complexity and the specialized instruments required.

2.2. Electrochemical Sensing Methods

2.2.1. Voltammetry

Voltammetry stands as a robust electrochemical technique, wielding the capability to detect and quantify an array of analytes, including neurotransmitters, within biological specimens. Among its forms, fast-scan cyclic voltammetry (FSCV) emerges as a particularly efficacious means for probing neurotransmitter dynamics in the brain.
FSCV encompasses applying a modest voltage ramp to a carbon-fiber microelectrode immersed in a sample containing neurotransmitters. The progression of the voltage ramp precipitates shifts in electrochemical reactions at the electrode interface, resulting in a distinctive current that the system captures. Through the temporal analysis of current alterations, researchers can deduce the presence and concentration of specific neurotransmitters within the sample [3,23].
An important attribute of FSCV lies in its capacity to expeditiously cycle through numerous voltage ramps within a condensed timeframe, typically spanning milliseconds. This expeditiousness enables real-time tracking of neurotransmitter release and uptake, offering insightful glimpses into the operational mechanics of these molecules in the brain. FSCV’s repertoire extends to monitoring shifts in neurotransmitter release prompted by disparate stimuli, encompassing electrical and chemical cues, therefore augmenting its versatility.
Despite its many advantages, FSCV poses technical challenges, mandating specialized equipment and proficiency. Attentive calibration, meticulous control of electrode positioning, and conscientious management of other experimental variables are pivotal to procuring precise and reproducible outcomes. Nonetheless, with diligent training and a meticulous approach, FSCV evolves into a potent instrument for scrutinizing neurotransmitter dynamics in states both normative and pathological. Notably, the advent of advanced tools has demonstrated FSCV’s aptitude for detecting neurotransmitters at low concentrations [24,25,26,27,28]. Moreover, FSCV exhibits compatibility with other techniques, exemplified by its synergy with Raman Spectroscopy, culminating in a hybrid sensing platform that merges spectral and electrochemical data of the sample [29,30].

2.2.2. Amperometry

Amperometry, an extensively employed electrochemical technique, holds prominence in neurotransmitter detection. It entails the application of a steady potential to a working electrode, measuring the resultant oxido-reduction reaction current, a measure proportional to the analyte concentration. The current flowing through the working electrode, in relation to a reference electrode, undergoes assessment. Of note, the temporal resolution of amperometry is not confined solely to the cycle duration, rendering it apt for scrutinizing neurotransmitter release kinetics.
To ascertain neurotransmitters, like catecholamines and indolamines, a carbon-fiber microelectrode assumes frequent use. This microelectrode maintains a voltage surpassing the oxidizing potential of the neurotransmitter. Upon neurotransmitter release, the emitted electrons are channeled to the electrode, producing a quantifiable current. The temporal resolution of amperometry contends with two factors: neurotransmitter diffusion towards the electrode and electron transfer kinetics.
The electrode-measured current hinges on the released neurotransmitter concentration, although the released neurotransmitter per se remains unidentified. To remedy this, a complementary approach, such as high-performance liquid chromatography, becomes requisite. Researchers bolster amperometry’s selectivity by modifying sensor surfaces with specific enzymes. Nevertheless, biological samples can introduce interference, sparking the evolution of numerous updated strategies.
Despite its merits, amperometry grapples with limitations: modest temporal-spatial resolution, susceptibility to interference in biological samples, and challenges in identifying precise neurotransmitters. Nonetheless, amperometry remains a popular method for neurotransmitter detection, as demonstrated by recently published papers [31,32,33,34,35,36,37].

2.2.3. Electrochemical Sensing Methods for In Vivo or In Vitro Applications

Electrochemical sensing methods stand out as favored approaches for neurotransmitter detection. Their inherent simplicity and swift detection pace render them superior choices for neurotransmitter monitoring, especially in comparison to alternative techniques. Additionally, their adaptability proves noteworthy; by employing diverse electrode types and varying wavefronts, these methods can be tailored and refined to target specific molecules or environments effectively.
However, these techniques hinge on implantable electrodes that necessitate precise positioning and calibration to yield precise data. Ongoing endeavors by researchers are aimed at advancing implantable electrodes for in vivo measurements, exemplified by the work of Moldovan et al. [38], who presented a brain-implantable multifunctional probe for simultaneous detection of glutamate and GABA neurotransmitters. Nonetheless, we contend that the true potential of these techniques might lie in in vitro sensing, as demonstrated by their application preceding the shift towards in vivo objectives.
These methodologies could seamlessly integrate into miniaturized LoC in vitro neurotransmitter monitoring platforms, provided the electrodes are implanted into cells post-growth. Once inserted and accurately calibrated, these electrodes could persistently monitor neurotransmission processes, harnessing high temporal and spatial resolution in tandem with the technique’s selectivity and sensitivity.

2.3. Sampling and External Analytical Detection Methods

Microdialysis (MS) stands as a technique adept at sampling extracellular fluids, particularly within the brain, to gauge the concentration of diverse molecules, including neurotransmitters, peptides, and metabolites. Its implementation entails inserting a microdialysis probe into the desired tissue infusing it with a sterile physiological solution (the perfusate) at a gentle flow rate. This probe, featuring a semipermeable membrane at its tip, permits unhindered diffusion of small molecules between the perfusate and extracellular fluid.
As the perfusate courses through the probe, it equilibrates with the neighboring extracellular fluid, allowing molecules of interest to traverse the membrane into the perfusate. The collected perfusate subsequently undergoes analysis through various techniques to measure the target molecules’ concentrations. Remarkably, microdialysis lends itself to continuous extracellular fluid sampling in in vivo contexts, setting it apart from techniques restricted to singular or temporally limited observations [39]. Another advantage emerges from the ability to employ the same probe for introducing specific reagents at the measurement site, therefore inciting subsequent measurable reactions [40].
In the realm of neurotransmitter sensing, microdialysis facilitates the direct monitoring of neurotransmitter release at the synaptic level in response to diverse stimuli like drugs, stressors, or even neurodegenerative diseases. By tracking shifts in neurotransmitter concentrations over time, researchers glean insights into the regulation of neurotransmitter release and the underlying mechanisms governing neuronal activity. Moreover, microdialysis can assess neurotransmitter clearance from the extracellular space, furnishing information about neurotransmitter uptake and metabolism in the brain.
It is essential to note that since microdialysis merely extracts specific compounds from target tissues, external analyses are essential to process the obtained perfusate [41,42]. To bolster selectivity, researchers often integrate complementary techniques with microdialysis. Notably, high-performance liquid chromatography (HPLC) and capillary electrophoresis (CE) are frequently used to segregate neurotransmitters from microdialysis-obtained perfusate. Although both techniques serve neurotransmitter analysis, they diverge in mechanisms and analytical capabilities.
CE operates on the separation principle of charge and size differences, relying on a narrow capillary filled with a buffer solution through which an electric current passes. The sample is introduced at one capillary end, and components move along the capillary, separating based on electric field-induced movement. Highly sensitive and requiring minimal sample volumes, CE efficiently detects trace neurotransmitter quantities [11,43,44].
In contrast, HPLC hinges on separation according to chemical properties like hydrophobicity or polarity. Employing a column filled with a stationary phase, the technique segregates neurotransmitters and their metabolites in a biological sample, with high pressure propelling the sample through the column. Components are segregated based on their physicochemical attributes, resulting in a chromatograph with distinct peaks corresponding to different compounds. HPLC proves precise and adept at separating complex analyte mixtures, facilitating the identification and quantification of multiple neurotransmitters in a single sample.
These techniques excel in analyzing neurotransmitters due to their sensitivity and selectivity. When combined with microdialysis, they enable simultaneous measurement of multiple neurotransmitter concentrations, offering a comprehensive view of neurochemical shifts in the brain. Mass spectrometry (MS), another technique often amalgamated with microdialysis, deserves mention.
Mass spectrometry’s core principle involves ionizing a sample and detecting the resultant ions based on mass-to-charge ratios. For neurotransmitter analysis, molecules extracted via microdialysis are converted into gas-phase ions, followed by separation and detection according to mass-to-charge ratios using a mass analyzer. This technique provides a mass spectrum that charts ion abundance against mass-to-charge ratio, subsequently analyzed to identify and quantify target neurotransmitters. Software [45] programs can match sample mass spectra with a database of known neurotransmitter spectra, or selective detection of specific neurotransmitters can be achieved through multiple reaction monitoring (MRM), a targeted mass spectrometry technique.
In sum, mass spectrometry, characterized by high sensitivity and selectivity, proves invaluable for measuring neurotransmitters in biological samples. It has significantly contributed to neuroscience research, elucidating neurotransmitter roles in physiological and pathological conditions [46]. Microdialysis, coupled with external analytical methods, serves as a powerful tool for in vivo exploration of neurotransmitter release and clearance, extensively employed in neuroscience research to delve into the neurochemical basis of behaviors and diseases. Although these techniques are useful, they cannot be entirely miniaturized within LoC neurotransmitter sensor contexts, as other analysis techniques are still needed and cannot be fully miniaturized in their current forms. An alternative approach, as presented by Lendor et al. [47], entails using solid-state microextraction probes for local sampling and subsequent external analysis. The possibility of coupling microdialysis with solid-state microextraction probes within LoC technologies as a method of sampling neurotransmitters and utilizing separate analysis techniques amenable to miniaturization holds potential and is further described in the subsequent section.

2.4. Optical Sensing Methods

2.4.1. Fluorescence

Fluorescence detection revolves around measuring the fluorescence emitted by specific molecules when subjected to particular light wavelengths. However, neurotransmitters are not inherently fluorescent, necessitating their labeling with a fluorescent group to enable detection. The fluorescence intensity directly corresponds to the concentration of the target neurotransmitter. Adjacent to direct fluorescence measurements, techniques such as Förster Resonance Energy Transfer (FRET) and Photoinduced Electron Transfer (PIET) are employed, relying on changes in the fluorescence signal. Detection occurs by gauging fluorescence quenching in the presence of an acceptor molecule.
Fluorescence measurements can be combined with various techniques to detect neurotransmitters. On its own, fluorescence provides information on neurotransmitter concentration at the measurement site. Yet, coupling fluorescence with imaging techniques imparts spatial information alongside concentration data. For instance, fluorescence microscopy permits imaging of a region of interest while accurately assessing neurotransmitter concentration within it. This approach is useful for studying neurotransmitter release and uptake in live cells or tissues. Notably, these labeling techniques are mainly suited for in vitro applications due to the potential biological incompatibility of the labeling chemicals and the ease of measuring fluorescence signals using advanced high-resolution microscopes. Fluorescence measurements have yielded success in a plethora of in vitro research studies [48,49,50,51,52,53,54], with some instances of in vivo success [55,56].
Fluorescence imaging boasts high specificity, as well as temporal and spatial resolution [57]. It has been proven effective for neurotransmitter detection in ex vivo tissues. Yet, for the imaging aspect, in vivo use is constrained due to compatibility issues with suitable imaging techniques. Employing a fluorescence probe could facilitate in vivo measurements at the cost of some spatial resolution, although advancements in compact and miniaturized imaging technologies might render fluorescence measurements feasible for in vitro neurotransmitter detection within LoC platforms.

2.4.2. Chemiluminescence

Chemiluminescence is a detection technique involving the emission of light resulting from a chemical reaction. Much like fluorescence detection, this technique can employ either direct intensity measurement or differential measurement. When the chemical reaction directly involves the molecule of interest, the measured light intensity can be directly linked to the molecule’s concentration. Conversely, in cases where the molecule does not actively participate in the reaction, its presence can partially inhibit the reaction, causing a reduction in the resulting light production. The disparity in light intensity with and without the molecule’s presence correlates with its concentration.
Similar to fluorescence measurement, chemiluminescence measurements can achieve high sensitivity and selectivity, yet they necessitate supplementary equipment and should be paired with other techniques for optimal selectivity outcomes. This technique is commonly employed for in vitro analysis due to the chemical agents used and the detection methods not aligning well with in vivo applications. Recent strides in the field of chemiluminescence neurotransmitter sensing primarily showcase their results through in vitro analyses [58,59,60,61,62,63,64].

2.4.3. Optical Fiber Biosensor

Optical fibers are extensively utilized in various biodetection applications. They can serve as imaging mediums when combined with other detection techniques, but in scenarios involving direct detection of neurotransmitters, optical fibers can be modified to function as standalone detection vectors, especially when coupled with advanced silicon light-emitting device (LED) as their light source [65].
Through tapering the end of an optical fiber to a fine point, the light propagating within its core interacts with the surrounding medium via the evanescent field. Coating the tapered end with a reactive compound transforms the optical fiber into a detection probe.
In one approach, the optical fiber’s tapered end is coated with fluorophores. The evanescent field generated by the fiber excites the coated fluorophores, with the resulting emission being propagated a short distance in the surrounding medium. This setup allows for precise spatial measurements of the target molecules [66,67].
Another method involves coating the optical fiber with aptamers. Here, detection involves measuring the light transmitted and reflected within the optical fiber. Specific aptamers bind with the target molecule, inducing a change in their conformation. This alteration in the aptamer’s structure affects the refractive index of the medium surrounding the optical fiber, modifying its transmission properties. Zhu et al. demonstrated a similar concept using gold and molybdenum disulfide nanoparticles functionalized with acetylcholinesterase instead of aptamers, enhancing sensitivity [68,69].
Given their thinness, optical fibers minimally disturb the medium in which they are employed, making them suitable for in vivo probing [70]. They can also be employed for ex vivo or in vitro measurements for the same reasons. Although the equipment and techniques associated with optical fiber biosensors are less intricate compared to others, enabling the miniaturization of biosensors, the trade-off lies in the spatial measurements, as individual optical fibers interact with limited volumes of the medium at a time.

2.4.4. Electromagnetic Detection

Two key techniques arising from the electromagnetic theory of photon-matter interactions are employed to detect and identify molecules.
First, Surface-Enhanced Raman Spectroscopy (SERS) enhances Raman scattering through molecule-surface interactions. This phenomenon stems from the excitation of localized surface plasmon resonance in surface molecules upon exposure to electromagnetic emission. The resonance frequency alters when the target molecule interacts with the surface, yielding composition information. SERS can enhance Raman scattering by up to 1010 times, enabling single molecule detection. It offers high sensitivity and specificity and facilitates multiplexed detection of multiple neurotransmitters concurrently. For optimal sensitivity and selectivity, functionalized surfaces are crucial for each molecule. These surfaces often involve nanostructures like gold or silver nanorods/nanoparticles to generate high electromagnetic fields. To further enhance the technique’s effectiveness, plasmonic–magnetic silica nanotubes and aptamer-functionalized nanoparticles are used to augment the enhancement factor.
Although SERS promises impressive sensitivity and selectivity, it requires specialized and complex equipment. Nonetheless, it remains a widely popular technique for neurotransmitter detection [30,71,72,73,74,75,76,77,78,79,80,81,82,83,84,85,86,87,88,89,90,91,92,93,94,95,96,97,98,99,100,101]. In recent works, research teams are exploring implantable SERS-based nanoprobes for direct neurotransmitter detection in the brain [69,102,103,104,105].
On the other hand, Localized Surface Plasmonic Resonance (LSPR) leverages the plasmonic resonance of nanostructure colloids to detect molecules of interest. Like SERS, this technique relies on molecule-nanostructure interactions, leading to changes in plasmonic resonance. However, here, nanostructures are dispersed in a fluid colloid rather than being confined to a surface. Detection in LSPR does not hinge on Raman scattering; instead, it relies on colorimetry analysis. The base plasmonic resonance of nanostructure colloids results in specific resonance absorbance in response to incoming electromagnetic spectra. This absorption band, called the plasmonic resonance frequency, shifts upon the interaction of the molecule of interest with the nanostructures. This shift provides concentration information. To amplify this interaction, nanostructures can be functionalized with aptamers or antibodies, strengthening the interaction and increasing the plasmonic resonance band shift.
In contrast to SERS, LSPR detection is accomplished using simpler devices. Since colloid plasmonic resonance band analysis essentially involves colorimetry, standard spectrophotometry instruments suffice. Miniaturized optical instruments facilitate the implementation of LSPR in LoC setups and miniaturized implantable devices. However, both LSPR and SERS techniques share a limitation: they often rely on toxic substances in the form of metallic or nanostructure colloids, making them unsuitable for in vivo analysis. To address this, research focuses on developing biocompatible, functionalized ultrastable nanoparticles, aiming to design an LSPR technique that, in conjunction with miniaturized devices, can be employed in vitro or as implantable sensors [68,106,107,108,109,110,111,112,113].

2.5. Comparison of Sensing Methods

In the previous sections, many different neurotransmitter sensing techniques were outlined. Those techniques are all sensing methods used and found in today’s literature. Table 1 lists those methods and highlights their ease of use.
Finding an objective comparison for all cited methods is challenging. For example, a technique that is superior in sensitivity can also be inferior in ease of use or not as selective as another. The comparison and the identification of the superior techniques all depend on the specific intent of the user. In this review, we compare the efficiency of the techniques based mainly on ease of use as well as its miniaturization potential. Of course, the sensitivity and selectivity of the measurements are important. However, the usefulness of a sensing technique is not solely based on the sensitivity or selectivity as it depends on the use case. A better comparison basis would be the usability of the technique for a specific purpose. The definition of usability of a process or system, as defined by the International Organization for Standardization (ISO) [ISO 9241-11:2018] [117], is a combination of effectiveness (the accuracy and completeness with which specified users can achieve specified goals in particular environments), efficiency (the resources expended in relation to the accuracy and completeness of goals achieved) and satisfaction (the comfort and acceptability of the work system to its users and other people affected by its use) of the process or product in question. Consequently, the usability of each neurotransmitter sensing technique depends on the application. It is thus difficult to compare all the sensing techniques together to identify the superior one with an objective approach. In the scope of this review, we focus more on the miniaturization potential and the potential for its application to an in vitro instrument.
In that sense, we can compare techniques together based on their in vivo or in vitro usage.

Comparison of Sensing Methods

In vivo measurements provide valuable insights into the dynamics of neurotransmitter release and uptake in their natural physiological and pathological contexts. They allow researchers to observe how neurotransmitters function in living organisms, which is crucial for understanding the complex processes that occur in the body. However, in vivo measurements come with significant challenges, including the complexity of the environment, low neurotransmitter concentrations, potential interference, and variations between individual organisms.
In vitro measurements, on the other hand, offer a more controlled and reproducible environment. Researchers can manipulate variables and obtain precise measurements of specific neurotransmitters. This controlled environment can lead to higher sensitivity and specificity in the measurements. However, in vitro measurements may not fully capture the complexity and dynamics of in vivo activities, and the results may not directly apply to living organisms.
To address the need for more compact and autonomous instruments for neurotransmitter detection, there is potential to shift towards in vitro measurements. Microfabrication technologies can play a crucial role in miniaturizing existing detection techniques. Although some techniques, like PET scanners, may not be cost-effective to miniaturize for in vitro use, others, such as fluorescence, chemiluminescence, optical fibers, LSPR, amperometry, voltammetry, and microdialysis combined with HPLC or CE methods, show promise for miniaturization in the context of in vitro neurotransmitter detection instruments.
By miniaturizing these techniques and creating LoC or small-scale in vitro sensors, researchers can benefit from controlled environments, reproducible results, and the ability to manipulate and measure specific neurotransmitters with high precision. This approach can complement in vivo measurements and provide valuable insights into neurotransmitter function, particularly in drug development, neuroscientific research, and clinical diagnostics.
Ultimately, the choice between in vivo and in vitro measurements should align with the specific research objectives, and a combination of both approaches may offer the most comprehensive understanding of neurotransmitter dynamics and their role in various physiological and pathological conditions.

3. The Future of Neurotransmitter Sensors

As was presented previously, many different technologies already exist for the detection of neurotransmitters both in vivo and in vitro, which uses instruments ranging from extremely bulky and encumbering to compact, portable, and even miniature. We believe that the next generation of neurotransmitter sensing instruments will stand with the design of even more compact and miniature instruments as they are both easier to use generally and less costly than their larger counterpart. The potential benefits of such miniaturized instruments are significant, including increased accessibility, reduced costs, and more efficient data collection and analysis.
However, the development of high-sensitivity and high-selectivity miniature neurotransmitter sensing platforms does come with its challenges. Achieving the required level of sensitivity and selectivity while also ensuring reproducibility and reliability can be complex. Researchers need to consider factors such as sensor design, material selection, integration of different techniques, and optimization of signal-to-noise ratios.
By creating a bridge between in vivo and in vitro measurements, researchers could potentially overcome some of the challenges associated with in vivo measurements, such as variability between subjects and interference from the biological environment. These in vitro platforms could serve as valuable tools for validating the accuracy and reliability of in vivo measurements, providing complementary insights into neurotransmitter dynamics.
As with any technological advancement, collaboration between scientists, engineers, and researchers from various fields will be crucial in achieving success. Developing novel miniature in vitro platforms for neurotransmitter sensing requires interdisciplinary efforts, combining expertise in materials science, microfabrication, biology, and neuroscience.
Furthermore, an additional factor supporting the necessity for a new generation of small-scale sensors, such as LCOs or other in vitro instruments, lies in the ongoing transformations within the domain of live animal testing. Evidently, the recent prohibition of live animal testing within the cosmetic sector has triggered a shift in the practices of Canada’s regulatory authorities, aligning with a broader global trend steering away from live animal utilization in research endeavors [118,119,120,121]. This trajectory, initially embraced by pioneering nations including the United Kingdom [122], the European Union [123,124,125,126], and the United States [127,128,129], heralds a transformation that, in our estimation, will redefine the landscape of research methodologies in the future. Although presently confined to specific domains, we anticipate that these regulatory shifts will exert a profound influence on the broader research landscape. In this regard, the exploration of alternatives that circumvent the need for live animal or human testing becomes imperative.
Another pivotal dimension driving the transition from in vivo investigations to in vitro studies is the growing apprehension among scientists regarding the accuracy of animal models vis-à-vis human models. In essence, a cadre of researchers has underscored instances where animal models have proven inadequate in faithfully replicating observations subsequently witnessed in analogous human models within the same studies [130,131,132]. These discrepancies have manifested across diverse fields of study, spanning disciplines such as toxicology [133], pathology [134,135], and neurology [136], among others. In response to this predicament, a novel paradigm is being advocated, a paradigm that resembles closer to human models while veering away from animal models that have demonstrated suboptimal fidelity to their human counterparts.
Our stance pivots on the recognition that animal models may, in certain instances, lack fidelity with human models across diverse fields of study. However, animal models retain their pertinence in specific contexts and, provided they are employed judiciously and ethically, continue to constitute a valuable resource in the scientific pursuit of human advancement.
A novel research trend has emerged in response to the aforementioned regulations and concerns, aiming to discover alternatives to animal experimentation. This research avenue is dedicated to exploring New Approach Methodologies (NAMs) that can yield equivalent outcomes to those achieved through live animal experimentation. In pursuit of this objective, various scientific journals [137,138] and conferences [139] have been established, providing platforms for scientists to showcase their progress in NAMs and related in vitro measurement techniques. Researchers in this field are directing their efforts towards substituting traditional in vivo analysis methods with alternatives, therefore mitigating the reliance on animal subjects. They are devising innovative means to attain comparable outcomes by harnessing in vitro, in chemico, and computational (or in silico) strategies [140,141,142,143].
The adoption of LoC and OoC devices has gained prominence within these alternatives, aiming to replace live subjects in experimentation [144,145]. This evolution emphasizes the importance of adapting existing techniques for application within such devices to shape the future landscape of research. In this regard, a prudent approach involves the adaptation of established in vitro techniques that have proven useful while identifying viable candidates among in vivo techniques that can be transposed to an in vitro context. In the preceding sections, a comprehensive overview of various techniques was presented alongside recent applications. In the subsequent section, we will evaluate each technique to identify those that align most favorably with LoC and OoC devices while also identifying those less suited for in vitro measurements.

3.1. Envisages Miniaturized Hybrid Neurotransmitter Analysis Platform/Device

As the era of in vivo measurements gives way to a growing emphasis on in vitro approaches, a novel class of instruments is required to provide researchers with the capacity to advance our understanding of neurotransmitters. To do so, a new generation of neurotransmitter in vitro measurement devices becomes necessary.
In this context, we propose LoC and OoC-based instruments as the new generation of sensors. These cutting-edge devices are currently undergoing development, progressively augmenting their capabilities and poised to supplant animal and human models in the realm of biochemical analysis [146]. By offering an in vitro counterpart to animal or human models, LoC and OoC devices offer an alternative avenue to in vivo analysis [147]. This paradigm is especially advantageous for disciplines necessitating specific conditions or model characteristics that are challenging to replicate in in vivo animal or human models but are more controllable within artificial in vitro constructs. This holds for disease investigations and diagnostics, where the versatility and control offered by these devices prove invaluable [148,149,150,151,152]. Moreover, such platforms furnish a controlled and reproducible environment, ideally suited for the nuanced exploration of intricate processes and delicate organs, such as the brain [153,154,155].
For studies focused on neurotransmitters, the integration of LoC and OoC technologies emerges as highly favorable. These hybrid platforms (integrating LoCs with OoCs on the same platform) enable researchers to cultivate precise conditions and harness specific neurons vital to their analyses, all within a controlled and replicable environment [156,157,158,159,160]. The ability to embed or implant probes for neurotransmitter measurements is greatly facilitated, owing to the comprehensively regulated parameters that characterize these platforms, an achievement that remains difficult in traditional in vivo investigations.
To create a viable LoC or OoC platform capable of ultimately supplanting in vivo analysis, several essential requisites must be fulfilled. First, the device must faithfully emulate the subject of interest, mirroring the attributes of the animal or human model. In pursuit of this aim, the utilization of organelles or cultivated biological constructs has emerged as an apt approach for such investigations [146]. To nurture and sustain this biological matrix within conditions akin to in vivo environments and to manipulate the matrix without compromise, a microfluidic framework stands as a promising solution. The inherent attributes of microfluidics facilitate the controlled infusion and circulation of fluids containing the requisite components for cellular growth and viability in vitro. Furthermore, this technology enables the precise delivery of reagents and the extraction of samples for subsequent analyses, all while preserving the integrity of the biological matrix. The efficacy of microfluidic platforms for LoC and OoC devices tailored to in vitro neuronal analyses has already been demonstrated [161,162,163,164].
The integration of a judiciously chosen miniaturized sensing approach and system is pivotal for the intended analysis within such a device. For instance, in the context of neurotransmitter detection, different choices of miniaturized analysis methods can be highlighted from the existing methods highlighted in Table 1. The reasoning of such a choice will be explored in the following subsection.
A pivotal requirement for all LoC and OoC devices resides in their physical dimensions. To truly rival the prevailing in vivo paradigm, the LoC and OoC-based NAMs must present more than a mere alternative; they must provide a distinctive advantage. A prominent asset intrinsic to these designs is their potential for compactness and miniaturization, a characteristic that can be harnessed to offer unparalleled convenience. A technology that can be used to help with the compact nature of such devices is 3D printing. Remarkably, the application of 3D printing technologies extends beyond the fabrication of mechanical components, encompassing the creation of microfluidic components as well [165,166,167]. The advancements in printer resolution have enabled the direct printing of intricate microfluidic channels within systems, therefore allowing for more streamlined and integrated configurations [168,169]. Notably, recent investigations have further harnessed 3D printing technologies to engineer biological matrices, therefore crafting two-dimensional or three-dimensional cellular frameworks for integration within LoC or OoC devices [163,170,171].

3.2. Existing Neurotransmitters Sensing Methods That Could Be Used for In Vitro Miniaturized Sensing Methods

In Section 2, we explored the existing neurotransmitter sensing methods and how they were best used. However, in the context of the future shift from in vivo to in vitro testing, we should decide which existing technique is best suited for this paradigm shift. Table 1 provided a review of the different techniques and their usage.
The first methods under consideration were medical imaging techniques, including MRI, MRS, PET, and SPECT. These techniques often involve in vivo imaging and are adept at examining the internal structures of specimens with remarkable spatial accuracy. However, the complexity of the techniques and the instruments required to generate these images is significant, and they are typically designed to accommodate human subjects. Although some miniaturized versions have been developed to accommodate smaller specimens, such as live mice [114,115,116], they are not commonly utilized. For the application of medical imaging techniques in in vitro neurotransmitter analysis, the development of a miniaturized version, ideally designed to fit around a Petri dish or similar container, would be necessary. Nonetheless, the challenges associated with miniaturization would persist, rendering this approach one of the more formidable to integrate into a compact LoC or OoC device.
The second set of techniques highlighted are electrochemical sensing methods, encompassing voltammetry and amperometry. These methods offer a relatively simpler sensing approach. They are rooted in the examination of the current response of a chemical compound under an applied potential, whether stable or variable. This entails the use of an electric probe, a variable power source, and a current meter. The data analysis necessary for the detection of the target chemical, such as neurotransmitters in this context, is comparatively straightforward, particularly when juxtaposed with more intricate methods like medical imaging. Furthermore, the probes employed can be fabricated at the microscopic scale using contemporary techniques, utilizing materials like carbon nanotubes or nanodots [25,34,35,36]. These electrochemical techniques have demonstrated success both in vivo and in vitro, with in vitro experiments often serving as a stepping stone for in vivo applications. Their relative ease of implementation makes them particularly suitable for establishing proof-of-concept in in vitro contexts, paving the way for future in vivo investigations. As a result, these methods are well poised for adaptation into a miniaturized in vitro neurotransmitter sensing platform built upon LoC or OoC architectures.
The third approach was microdialysis, a distinctive technique that deviates from direct neurotransmitter detection. Functioning more as a sampling method than a standalone detection technique, microdialysis extracts neurotransmitters from the analyzed sample. Although microdialysis is categorized here as a detection technique due to its integration with methods like HPLC for neurotransmitter analysis, its primary function is the extraction of the target molecules from the sample. This technique is primarily employed for in vivo neurotransmitter sampling, facilitating the collection of specimens for subsequent external analysis. In the context of in vitro analysis, microdialysis does not inherently hold a primary role, as many in vitro analyses do not necessitate extensive sampling. However, its integration into OoC or LoC devices could be envisaged. OoC or LoC devices might require sampling for external analysis of the molecules of interest. The miniaturization of microdialysis has been accomplished, yielding compact dialysis probes capable of extracting sample volumes as minute as nL. When coupled with an OoC or LoC device, this miniaturized microdialysis could potentially enable robust in vitro neurotransmitter analysis. This approach could be particularly effective if combined with a complementary secondary analysis method, such as HPLC.
The fourth method encompasses chemiluminescence techniques, including both fluorescence and chemiluminescence-based detection. Fluorescence and chemiluminescence are primarily suited for in vitro analysis, given that the reactive compounds employed in these methods often possess toxicity that makes them ill-suited for in vivo applications. In some instances, fluorescent dyes have been utilized in vivo when bound to nanoparticles, serving as the detection vector for these nanoparticles. This combination has demonstrated certain degrees of biocompatibility, enabling in vivo analysis. However, for the ease of use and reduced concern over biocompatibility, employing the fluorescence dyes or chemiluminescent reagents directly in in vitro analysis is preferable. These chemiluminescence-based analysis methods align well with the notion of a miniaturized neurotransmitter detection platform integrated with LoC or OoC devices. Their integration would not compromise the compact dimensions of these devices. The primary requirement here would be to incorporate suitable sensing techniques to capture the luminescence or fluorescence produced by the compounds in the presence of neurotransmitters. Integrating these sensing techniques into the LoC or OoC device would then create a synergistic in vitro neurotransmitter analysis system.
The fifth method encompasses optical fiber biosensors, which operate as hybrid techniques incorporating other sensing approaches for detection or delivery. One example involves using optical fiber bioprobes in conjunction with the SERS technique, achieved by applying a functionalized layer of gold nanoparticles to the bioprobe’s tip and measuring the resulting SERS signal at the probe’s location. Similarly, a similar bioprobe can be employed in combination with fluorescence measurements, wherein the exciting light is injected into the sample, and the emitted fluorescence light is measured from the sample. Optical fiber bioprobes hold utility both in in vivo and in vitro analysis due to their versatile nature, much akin to electrochemical or microdialysis probes. Furthermore, the fabrication techniques for optical fibers are well-established, rooted in their extensive use in the realm of telecommunications, with similar principles applied to the creation of bioprobes. Overall, optical fiber bioprobes offer a promising avenue for in vitro miniaturized neurotransmitter sensing methods. Their compatibility with LoC or OoC devices could enable precise neurotransmitter measurements within samples, provided that the appropriate secondary sensing method is thoughtfully integrated into the device.
The sixth method falls under the classification of electromagnetic detection techniques, comprising LSPR and SERS measurement methods. Although these two techniques differ considerably, they share a common underlying principle. SERS is generally more prevalent than LSPR, offering a higher detection threshold and enhanced data resolution due to its distinct measurement approach. Nonetheless, SERS is a more intricate technique, demanding advanced analysis methods and instruments in comparison to the relatively simpler requirements of LSPR. LSPR is primarily utilized for in vitro analysis due to its inherent detection nature. For instance, a common LSPR detection technique relies on colorimetry measurements, which prove more challenging to implement in vivo compared to in vitro settings. Similarly, SERS also finds more frequent applications in vitro due to the precision demands of instruments for high-resolution data. Notably, recent research endeavors have extended SERS to in vivo neurotransmitter analysis by harnessing its strengths in combination with the capabilities of optical fiber bioprobes. Looking ahead, the simplicity and user-friendliness of LSPR render it more suitable for miniaturized in vitro neurotransmitter sensors, making it a feasible choice for integration within LoC or OoC devices. Although the potential application of SERS in a similar manner is not implausible, the adoption of LSPR appears more straightforward, offering high resolution and detection limits under appropriate conditions.

3.3. Discussion

The future of neurotransmitter sensing, and indeed many other biochemical analyses, lies in the evolution of in vitro sensing platforms that can overcome the limitations of in vivo animal models. This transition is partly driven by changing perspectives on animal testing in the public eye and within scientific communities. Stricter regulations are moving towards reducing the use of animals in scientific research. Additionally, flaws in animal models have been exposed when compared to human models, which they were meant to mimic.
Furthermore, in vivo analysis is inherently complex, presenting numerous challenges and uncertainties that are hard to control, leading to difficulties in reproducibility. To address these changes and challenges, a new era of systems that does not rely on animal models or in vivo techniques is required. In response, in vitro LoC and OoC devices have been identified as the preferred options moving forward. These platforms offer researchers the control and reproducibility that in vivo measurements often lack. They are also inherently simpler to use, potentially offering a more autonomous and user-friendly approach.
To create an effective in vitro LoC neurotransmitter sensing platform, an appropriate sensing technique should be chosen and integrated into the LoC platform. Not all neurotransmitter sensing techniques are suited for this application, as some require large and complex instruments and techniques. The ideal techniques for this purpose should be minimally invasive and simpler than others while maintaining a high degree of sensitivity and precision, as they were designed for in vivo applications. Such techniques would readily apply to in vitro LoC neurotransmitter platforms.
In terms of fabrication, cutting-edge techniques should be employed to create a LoC system that is compact, simple to use, and offers a high degree of sensitivity, precision, control, and reproducibility over experimental conditions.
The envisioned system that aligns with these requirements would be an in vitro-based LoC or OoC system. This experimental platform would consist of a miniaturized controlled receptacle where a neural matrix of neurons would be cultivated. Alongside it, a biochemical control platform equipped with various environmental sensors and a microfluidic system would monitor and nourish the neural matrix to replicate in vivo conditions, facilitating its growth and fulfilling its primary needs. On the other hand, a neurotransmitter sensing platform based on a specific sensing method, whether electrochemical or optical, would apply controlled and reproducible conditions to the matrix to monitor changes and collect data induced by these conditions.
The entire system would be compact and autonomous, with users only needing to set up the system for experiments and subsequently analyze the data to draw conclusions.
The creation of such a device is feasible using modern fabrication techniques. The electrical and mechanical aspects of the system are based on established techniques and are not challenging to apply. However, the real challenges lie in the sensing and incubation platforms. For the sensing system, work has already been done toward compact and autonomous neurotransmitter sensing systems based on techniques well-suited for in vitro models. Some examples of such systems can be found in Table 2. These systems can continue to improve in the future, increasing their sensitivity, selectivity, and miniaturization. In terms of the incubator, numerous technologies are available for creating such a system, many of which have been used for similar instruments presented in the literature. Given the wide variety of technologies, exploring existing options to identify their pros and cons will be essential for selecting the most suitable one.
Overall, there is confidence that the scientific community is moving toward a new era of in vitro biochemical analysis platforms. Researchers are actively working toward this goal. However, given the diverse range of sensing techniques, fabrication processes, and applications, there is no one-size-fits-all solution that will yield superior or faster results than others. Steady advances in various areas will collectively pave the way for true in vitro LoC neural sensing platforms, replacing current in vivo models and contributing to a deeper understanding of the brain. The future holds the answers to these unfolding developments.

4. Fabrication of LoC or OoC Type Device for the New Generation of In Vitro Sensors

For the next generation of in vitro sensors, a range of both new and existing technologies can be harnessed to design and fabricate integrated LoC or OoC devices. In this context, an optimal approach would involve incorporating the necessary sensing method along with a micro-incubator to cultivate and maintain viable cells throughout the experimental process. This comprehensive setup would enable in vitro experiments to encompass all essential elements required for studying cells directly within a controlled environment, facilitating autonomous monitoring and management of the entire experimental process.
This section offers a comprehensive overview of various fabrication techniques employed to integrate micro-incubators with sensing systems. These components, when combined, create a compact and autonomous in vitro LoC device that holds tremendous potential as the future of sensor technology. The subsequent exploration of these fabrication methods delves into the practical aspects of this innovation, illuminating the inherent possibilities stemming from the convergence of these advanced technologies.

4.1. C O 2 Based Incubators

An incubator serves as a controlled environment designed to provide the optimal conditions for the growth and thriving of cellular cultures. The growth of cells necessitates precise maintenance of factors such as temperature, humidity, and pH levels. This is achieved through a combination of elements within the incubator, including a heating mechanism, an air circulation system, and an array of sensors for continuous feedback.
To ensure proper pH control, the gas composition within the incubator plays a crucial role. Typically, the incubator atmosphere consists of air enriched with 5% CO 2 . The acidic nature of C O 2 interacts with the slightly basic growth medium, facilitating pH regulation through diffusion across a specialized membrane. By modulating the flow of gas, precise control over the pH of the medium can be achieved. Meanwhile, temperature regulation is achieved by modulating the heating elements through which the gas circulates, analogous to a conventional convection oven.

Control of pH Using a Physiological CO 2 /HCO 3 -Based Buffering Regime

Within culture chambers, a buffering system is employed to maintain pH stability. The CO 2 /HCO 3 buffering system is recognized as a pivotal extracellular buffer within bodily fluids [172]. In this system, CO 2 functions as an acidic gas, while HCO 3 acts as a soluble base.
The buffering capacity is achieved by introducing HCO 3 salt into the medium. This salt reacts with the layer of CO 2 -enriched air above it, effectively regulating the pH within the incubator chamber. However, to ensure the stability of this system, accurate monitoring of pH levels is imperative. Spectrographic analysis serves as a valuable tool for this purpose. Specifically, a dye such as Phenol Red (PhR) is introduced into the growth medium, and its absorbance spectrum is subsequently analyzed using computational techniques. This analysis enables precise determination of pH levels based on the characteristic spectrum of the dye [172].

4.2. Materials for Incubator Fabrication

In the context of fabricating integrated micro-incubators, the selection of appropriate materials is of paramount importance. This section delves into the pivotal process of material choice, emphasizing their critical role in the successful construction of these advanced systems.

4.2.1. PDMS as a Structural Material

Polydimethylsiloxane (PDMS), an organic polymer derived from silicon, holds a significant position in microfluidics applications. Its popularity stems from its suitability for prototyping, controllable mechanical properties, and biocompatibility. The cost-effectiveness of PDMS makes it an ideal candidate for rapid and economical micro-incubator development. Additionally, its affordability facilitates the use of disposable microfluidic systems, a feature particularly advantageous for single-use cellular culture applications, eliminating the complexities associated with cleaning intricate microfluidic structures. PDMS also permits the fabrication of three-dimensional components with more intricate internal structures than achievable with conventional materials like glass.
An illustrative instance of PDMS utilization is demonstrated in the incubator design by Blain et al. [173], where the incubator chamber is predominantly fashioned from PDMS. Notably, the only exceptions are the heating elements and the associated electronics responsible for temperature regulation. The latter, being non-contact components, and the former, constructed from silicon enveloped in aluminum for enhanced heating capabilities, are not in direct contact with the growth medium.
Furthermore, PDMS’s gas permeability allows for the creation of membrane elements, presenting opportunities for specialized incubator configurations. However, this permeability can pose challenges, particularly when dealing with intricate gas manipulation channels susceptible to external gas effects or leakage. Establishing a vacuum within a PDMS-constructed incubator chamber may prove infeasible. Nonetheless, strategic implementation of protective layers atop PDMS can enable vacuum conditions [174], enabling the realization of intricate PDMS-based designs involving complex gas control.
PDMS exhibits noteworthy temperature resistance, enduring temperatures up to 350 degrees Celsius when adequately cured [175]. However, its limited chemical compatibility hampers its application in settings involving organic solvents [175]. Similar constraints also apply to other polymers suitable for microfluidic devices.

4.2.2. Glass as a Structural Material

Glass has a long-standing history as a foundational material for microfluidic channels. It was the primary choice before the rise of PDMS and remains relevant in certain contexts. Glass-based microfluidic channels are renowned for their transparency, an attribute that facilitates direct integration with microscopes or similar devices for real-time culture observation—a feature that holds particular appeal for micro-incubators.
Incorporating glass into incubator designs is not uncommon, often in conjunction with materials like aluminum, due to the complexities associated with fabricating intricate 3D glass structures [176]. The transparency of glass also allows for direct observation of cultures when coupled with a microscope. Although PDMS structures can also be used for this purpose to a certain extent, they tend to become contaminated by the culture media over time.
Glass microfluidic channels can be fashioned through lithography techniques similar to those employed in CMOS chip fabrication. The creation of 3D structures involves layering with thermal bonding [177]. However, these techniques are considerably intricate and demand advanced equipment. In contrast, PDMS molding offers a more practical avenue for prototyping applications.
A notable advantage of glass is its biocompatibility [178], rendering it suitable for prolonged cellular growth. The durability and moderate ease of cleaning associated with glass further bolster its appeal, making it a viable option for multi-use micro-incubator fabrication when structurally feasible.
It is important to note that glass-based incubators may still require membrane elements, typically based on materials like PDMS. By incorporating wear considerations of PDMS-based components into the design of glass incubators, a hybrid approach becomes viable. This hybrid strategy capitalizes on the strengths of both materials, facilitating glass cleanliness and PDMS replacement when necessary, therefore extending the device’s lifespan.

4.2.3. Silicon Photonic Crystals-Based Micro-Incubators

An innovative approach to micro-incubator fabrication involves the utilization of electrochemical micromachining on silicon wafers, resulting in a technology that can be produced at a large scale and a remarkably low cost [179]. This method offers the potential to address various challenges associated with conventional micro-incubators, such as cost-effectiveness, bulkiness, and limitations akin to PDMS or glass-based alternatives. This advancement paves the way for numerous biomedical integrated solutions, particularly in the realm of in vitro LoC sensing systems.
The technique proposed in this context enables the creation of micro-incubators on a miniature scale. The process entails the formation of a periodic array of gaps within the silicon through electrochemical etching. These gaps serve as compartments for cellular cultures to thrive, fostering growth and development. The cultivated cells reside within these silicon gaps, which are filled with a suitable growth medium, and the pH can be regulated using the CO 2 -based method discussed previously.
By integrating an external temperature control unit, this technology has the potential to evolve into a microbioreactor, which can then be transformed into a fully functional LoC system applicable across a wide range of applications [179]. This innovative approach not only contributes to cost-effective and versatile micro-incubator technology but also underscores its potential integration into advanced in vitro sensing platforms.

4.2.4. Thermoplastic Materials

Poly(methyl methacrylate) (PMMA) is a thermoplastic material frequently employed for microfluidic channel fabrication. Its properties make it a suitable choice for prototyping applications due to its ease of manufacture. Many techniques used to create microfluidic channels with PMMA can be adapted for other thermoplastics, such as cyclic olefin copolymer (COC) or polycarbonate (PC), which offer enhanced mechanical properties compared to PDMS, along with simpler manufacturing than glass.
One PMMA fabrication method involves maskless CO 2 laser etching of the PMMA substrate to generate microchannels [180]. After etching, the piece is cleaned with acetone to remove debris, and channels are sealed by affixing a glass plate atop the PMMA using epoxy, resulting in a waterproof microfluidic cell.
Thermal nanoimprinting lithography (Thermal-NIL) is another method [181]. Here, a silicon wafer is etched using maskless UV lithography to create a stamp. The heated stamp is pressed onto a PMMA wafer to imprint features, and channels are sealed by thermal bonding between the PMMA substrate and another PMMA cover. This process is scalable if the stamp remains usable, enabling cost-effective replication of microfluidic cells.
A similar technique uses SU-8 on a glass substrate, patterned via standard lithography, to create a stamp for imprinting [182].
PMMA’s biocompatibility, resistance to temperature stress, minimal chemical reactivity, and limited interference with bioprocesses make it well-suited for micro-incubator fabrication, aligning it with the requirements of integrated in vitro sensing platforms.

4.2.5. Choice of Material

The choice of material depends on the specific requirements of the application. Here are the key considerations for selecting the appropriate material for micro-incubator fabrication:
  • PDMS is a versatile choice suitable for prototyping, disposable applications, and scenarios where cost and simplicity are important. It allows for rapid fabrication and is well-suited for one-off or short-term experiments. PDMS is ideal when the focus is on quick testing and proof-of-concept.
  • Glass is a premium option, offering excellent biocompatibility, optical transparency, and durability. It is a suitable choice for applications where reliability, long-term culturing, and high-quality observations are essential. Although it is more challenging to manufacture complex structures, glass-based incubators provide a cleaner environment for extended cell culture.
  • Thermoplastics, such as PMMA, COC, and PC, strike a balance between PDMS and glass. They are suitable for applications where moderate production scalability, cost-effectiveness, and reasonable longevity are desired. Thermoplastics offer better mechanical properties than PDMS and can provide a compromise between ease of fabrication and quality of incubator structure.
In summary, PDMS is advantageous for rapid prototyping and disposable setups, glass excels in long-term and high-quality culturing environments, and thermoplastics provide a middle ground between ease of fabrication and durability. The choice should align with the goals of the experiment, the level of precision required, and the resources available for fabrication.

4.3. Designs of Micro-Incubators: Portable Circular Incubators

One prevalent design for microscope-mounted micro-incubators is a circular geometry, chosen to align with the circular lens of the microscope for convenient observation. The circular architecture not only simplifies the manufacturing process but also enhances temperature and pressure control due to the even distribution of cellular culture within the circular chamber [176].
To ensure controlled cell culture, maintaining proper pH levels is essential. The micro-incubator described by Ince, C. et al. [176] employs the same C O 2 -based system described in Section 4.1 for pH control.
Recent advancements in fabrication techniques have enabled the creation of circular micro-incubators at a significantly lower cost while achieving even higher levels of performance and control [183]. Temperature fluctuations can be minimized to as low as 0.05 degrees Celsius using a Peltier module thermally connected to the incubator’s base, along with a digital thermometer for precise temperature monitoring.
The incorporation of a Peltier module allows for temperature regulation both above and below ambient temperature, providing greater flexibility. The module is designed to handle transient temperature changes and can compensate for them in less than 5 min.
Such micro-incubator designs effectively accommodate both 2D monolayers and 3D tissue samples, making them versatile tools for various cell-culture applications.

4.4. Designs of Micro-Incubators: On-Chip Incubators

4.4.1. On-Chip Carbon Dioxide Generator

To eliminate the need for an external CO 2 supply, which typically involves a large compressed tank and a dedicated inlet controller, an onboard solution can be developed. Instead of relying on an external CO 2 source, an on-chip micro-heater can be employed to heat sodium carbonate (NaHCO 3 ) and generate CO 2 gas for pH regulation [184]. The micro-heater is positioned beneath the culture media, allowing the generated gas to rise through a PDMS membrane to control the culture’s pH.
It is worth noting that this method of CO 2 generation requires the micro-heater to be fueled with sodium carbonate. Additionally, micro-pumps are needed to draw and control the gas flow to accurately regulate the pH.
Enhancements to this micro-heater CO 2 gas source have shown improvements in the stability and viability of cell cultures over time [185]. One significant advancement involved using a mixture of sodium bicarbonate and sodium carbonate, resulting in more stable pH regulation. This upgraded system enabled the design of a pocket-size micro-incubator that operates without the need for pH feedback control. With no active pH regulation, the incubator can run on batteries for several days without external intervention.
In a notable application, epithelial cell cultures were maintained for 17 days using this system [185]. This technology opens possibilities for mailing cell cultures, allowing remote locations to send samples to main laboratories while preserving cell viability. The design focuses on portability, with heating element power consumption being a primary limitation. At around 500 mW power consumption, the incubator can realistically maintain cell cultures for up to a week during regular shipping. Further optimization of power consumption could potentially extend the stable culture period.

4.4.2. Real-Time Sampling and Observation

Another challenge in micro-incubators and cell culture is the real-time sampling and visual monitoring of cultures. A solution involves integrating an array of electrodes and optical sensors into the incubation chamber for continuous monitoring of cell growth [186]. The design includes micromachined microprobes, 10 platinum electrodes, 2 pH electrodes, and a temperature sensor, all of which allow active feedback. A video camera positioned above the incubator connects to a computer for optical monitoring, while a microfluidics system enables media insertion into the cell culture [186].
This integration enables the control of key parameters essential for observing cellular growth, making it suitable for maintaining and testing complex organisms that require real-time monitoring. The fabrication of such a device can be accomplished using silicon-based substrates. Etching the silicon substrate can create space for electrodes, the incubation chamber, and pH probes, providing a versatile platform for various applications.
Potential applications of this device include medical, pharmaceutical, and toxicity monitoring in samples, as well as real-time monitoring of other biochemical processes based on electrochemical detection, such as neurotransmission.

4.5. Fabrication Processes

4.5.1. PDMS-Based Micro-Incubators

Due to its biocompatibility and utility in microfabrication techniques, PDMS is frequently employed in soft lithography to create micro-incubators. Notably, studies have demonstrated the successful fabrication of entire micro-incubators using PDMS as the primary material [173].
All PDMS structures are crafted using soft lithography, a technique that facilitates the curing of thermocurable polymers through additive manufacturing. This process involves creating a mold by adding layers of material where needed. To generate cavities such as those required for microfluidics channels, an additional material is introduced to create spaces for the deposition of the mold material. Subsequently, the original material is dissolved using a solution that does not affect the primary mold, leaving behind the desired structures. The mold is then filled with the polymer, after which the mold itself is dissolved in a solution, resulting in the final product, a precisely shaped PDMS component [187]. The molding process is described in detail by Rodrigue, H., Bhandari, B., Wang, W., and Ahn, S.H. [187]. This approach enables the fabrication of intricate and complex 3D PDMS structures, a material known for its biocompatibility [188].
For PDMS structures of less intricate complexity, more expedient molding processes are available [189]. This method involves a hybrid structure, commencing with a silicon pad onto which photoresist is applied through spin coating, much akin to the process employed with doped silicon wafers. The channel structure is created by subsequently removing the photoresist through plasma treatment, leaving a negative imprint. PDMS is poured and cured onto this negative imprint, and once fully cured, the PDMS structure is peeled off and attached to a PDMS plate featuring access ports for channels. This fabrication process facilitates more rapid automated production as PDMS only requires curing once. Additionally, the peel-off method eliminates the need to dissolve the inner canal, rendering it a cost-effective alternative.

4.5.2. Tunable Permeability PDMS Membranes

PDMS membranes provide precise control over gas exchange within PDMS structures. This characteristic can be effectively harnessed to regulate CO 2 concentrations within culture chambers of micro-incubators. This innovative approach offers enhanced control over cellular growth by enabling the regulation of gaseous environments without direct gas injection, which could otherwise lead to media displacement and turbulence in the culture medium—particularly problematic in specific incubator designs.
Although a method for countering the gas permeability of PDMS by sealing it with a coating was previously discussed [174], there are instances where increased or tuned gas exchange is required. For such applications, a PDMS membrane with varying gas permeability was designed [190]. This is achieved by altering the ratio of polymer to curing agent in the PDMS composition. This introduces a novel parameter for consideration during incubator design. However, such alterations require careful design considerations, as changes to PDMS composition can impact mechanical properties, potentially hindering the fabrication of certain structures.
This alteration in permeability is largely attributed to silicon chains. The inherent flexibility of silicon-oxygen (Si-O) chains creates spaces that enable gas molecules to permeate the polymer matrix. The movement of these Si-O chains displaces trapped gas molecules, allowing them to traverse the membrane [190].
To create these tunable membranes, varying ratios of polymer to curing agent (ranging from 5:1 to 20:1) can be employed. These membranes are crafted using the spin coating method. Membrane thickness is determined through the spin coating process, while the area is defined through cutting and peeling post-thermal hardening. The PDMS membrane is assembled between a hard PDMS interconnect and a glass substrate, resulting in a dead-ended microfluidic channel tailored for permeability testing. Gas is pushed through the channel at a controlled rate using a pump. By measuring the resulting pressure and volume of escaping gas, the membrane’s permeability can be determined using Equation (1) [190].
P = ν δ A t ( p 1 p 0 )
where P represents permeability, ν denotes gas volume through the membrane, δ signifies membrane thickness, A represents area, t stands for time, p 1 indicates high partial pressure, and p 0 signifies low partial pressure.

4.5.3. Rapid Prototyping of 3D Systems

A method for fabricating complex 3D PDMS components involves a combination of conventional spin coating and lithography techniques in a layered fashion, termed the “membrane sandwich” [191]. This technique entails the creation of two membranes through traditional means, followed by sandwiching them between thicker slabs for structural reinforcement. These robust slabs, often made of glass, are drilled at appropriate positions to allow fluid passage between layers within the 3D structure, therefore introducing a new dimension of complexity. This novel approach can be likened to the distinction between single-layer and double-layer printed circuit boards, therefore expanding the realm of possibilities.
Modifying the mechanical properties of the PDMS structure makes it feasible to stack PDMS membranes without the need for additional structural support layers. This advancement paves the way for entirely PDMS-fabricated incubators, excluding the electronic peripheral components.

4.5.4. Comparison of Fabrication Processes

Just as there exists diversity among types of incubators, the fabrication processes for these incubators are equally varied. The selection of a particular fabrication method may be influenced by the specific type of incubator under consideration, and in some instances, a certain method might even be essential. In the pursuit of engineering a micro-incubator for research, the optimal fabrication process aligns with the desired performance metrics and versatility demanded by the application. Table 3 presents a concise overview of the technologies discussed in the preceding sections.

4.6. Packaging and Integration of the LoC System

To realize a fully functional LoC system, the integration of a functional micro-incubation component with its associated peripherals is imperative. This integration facilitates the consolidation of various sub-systems into a singular instrument, enhancing portability and reducing the overall footprint compared to modular arrangements. A plethora of methodologies exist for achieving this integration.
One notable approach involves the fabrication of the micro-incubator directly into the sensing system. For instance, a complementary metal-oxide-semiconductor (CMOS) die can be repurposed as an electrode array for the detection of subtle electrical signals. In this setup, the micro-incubator chamber or channel can be fashioned from materials such as PDMS, glass, or other polymers seamlessly onto the surface of the CMOS chip. This design philosophy revolves around the amalgamation of integrated circuitry with microfluidic components to enable advanced sensing applications. By situating on-chip amplifiers beneath the sensing electrodes, the distance traveled by the signal from its source is minimized, leading to heightened signal-to-noise ratios (SNRs). It is crucial to note, however, that this fabrication approach entails certain trade-offs. Notably, the direct contact of the electrodes with the liquid medium within the incubator raises challenges in packaging to prevent issues such as leakage.
The integration of diverse technologies can manifest in numerous forms, contingent upon the specific experiment and application demands. Datta-Chaudhuri, T., Abshire, P. and Smela, E. [192] describe the predominant packaging techniques employed in microfluidic LoC systems in their work. Although the configurations of these packages can differ based on the unique application needs, the underlying fabrication process tends to maintain a degree of similarity across various packaging designs. This streamlined process stands as a formidable contender at the forefront of current practices due to its inherent simplicity, rendering it an elegant solution to the intricate packaging challenges associated with LoC systems.

4.7. Technology Comparison

In the realm of designing LoC systems with integrated micro-incubators, several critical factors come into play, including size, ease of use, and fabrication complexity. The dimensions of the incubator hold significant importance, influencing factors such as culture observation capabilities, mobility, and fabrication intricacy. Larger incubators generally afford enhanced culture observation, often featuring modular designs that are user-friendly and straightforward to fabricate, albeit at the expense of portability. Conversely, smaller incubators offer cost-effective manufacturing processes and precise operations, albeit with potential drawbacks in terms of culture size and versatility.
For a comprehensive overview of different technologies pertinent to the LoC micro-incubator systems, refer to Table 4, which presents summarized information delineating their unique characteristics and attributes.

5. Conclusions and Future Perspectives

In this comprehensive review, we have meticulously examined the recent strides in the field of neurotransmitter sensing, with a particular emphasis on their applications in both in vitro and in vivo contexts and their potential integration within LoC devices. We evaluated many different neurotransmitter sensing technologies, shedding light on their capabilities, limitations, and prospects.

5.1. Recent Advances and Trends

Our exploration of neurotransmitter sensing explored various domains. In the realm of medical imaging, significant progress has been observed, particularly in utilizing established techniques for monitoring neurotransmitters within neurodegenerative disease studies. Recent investigations have also delved into the impact of the SARS-CoV-2 virus on the brain, shedding new light on this critical area. Moreover, innovative amalgamations of imaging methods such as magnetic resonance spectroscopy (MRS) and positron emission tomography (PET) have been explored to glean comprehensive neurotransmitter maps. Although the miniaturization of these imaging techniques for LoC integration is yet to be realized, they remain pivotal in their conventional applications.
Electrochemical sensing, propelled by advanced materials like carbon-fiber-based bioprobes, has garnered substantial attention. These novel probes offer the dual advantage of compact size and heightened data resolution, rendering them invaluable for voltammetry and amperometry analyses of neurotransmitters. Encouragingly, the synthesis of these advanced probes presents an enticing synergy with LoC platforms, capitalizing on their portability and ease of use.
The dialysis approach to neurotransmitter analysis, facilitated by microdialysis probes, has sustained steady progress. Notably, the introduction of solid-state microprobes holds promise for the future, offering smaller form factors and enhanced usability. However, the pivotal challenge in this domain lies in the need for secondary analysis techniques such as high-performance liquid chromatography (HPLC) or mass spectrometry (MS), which have exhibited unmatched sensitivity and selectivity but have yet to be miniaturized for LoC integration.
Advancements in optical techniques have emerged as a formidable alternative, with fluorescence, chemiluminescence, surface-enhanced Raman spectroscopy (SERS), and localized surface plasmon resonance (LSPR) demonstrating remarkable sensitivities and selectivities. These techniques, whether harnessed alongside bioprobes or optical imaging, offer promising avenues for neurotransmitter detection. The pinnacle of these developments resides in the creation of optical fiber biosensors, capable of integrating diverse techniques to facilitate accurate neurotransmitter detection at targeted sites.

5.2. Future Perspectives

The future of neurotransmitter sensing seems very different than what is present at the moment. Amid shifting attitudes toward animal testing, in vitro analyses are poised to ascend, potentially relegating in vivo methodologies to a last resort. The evolution of in vitro alternatives assumes paramount importance to sustain neurotransmitter analysis and broader physiological studies, requiring platforms such as LoCs or OoCs devices to faithfully emulate in vivo conditions. The relentless pursuit of this goal is demonstrated in the progress of brain organoid models, offering promising 2D and 3D neuronal matrices for neurotransmission and brain chemistry analysis.
The trajectory of progress converges on the imperative development of compact, low-cost, and autonomous platforms. Herein lies the potential of LoCs as the future of neurotransmitter sensing. These platforms possess the dual advantage of obviating the need for animal models in in vivo analysis and conferring autonomy and controllability, facilitating the replication of experiment characteristics across trials. The advent of existing technologies that enable the amalgamation of artificial organs with direct sensing and monitoring techniques on a single platform underscores the capability of LoCs. As the methods of neurotransmitter analysis shift toward in vitro paradigms, a future where a micro-incubator chamber fosters the growth of disease-specific neurons alongside an integrated fiber optic bioprobe equipped with LSPR or SERS technology, all seamlessly controlled and analyzed by an onboard computer, seems feasible.
Although these goals promise a transformative future, there are still many difficulties to overcome, which would require the expertise of multidisciplinary collaboration to overcome. The pathway to realizing these platforms is obtainable, promising to revolutionize not only biochemical analysis but also democratize access to sophisticated research instruments for remote laboratories or research institutes that might not have access to advanced machines for those complex manipulations.

Author Contributions

Conceptualization, G.P.L., É.B., M.B. and A.M.; Formal Analysis, G.P.L.; Resources, É.B., M.B. and A.M.; Writing—Original Draft Preparation, G.P.L. and D.G.; Writing—Review and Editing, G.P.L., É.B., M.B. and A.M.; Supervision, A.M.; Project Administration, A.M.; Funding Acquisition, É.B., M.B. and A.M. All authors have read and agreed to the published version of the manuscript.

Funding

This project was possible due to the financial support from the National Research Council of Canada (NSERC).

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Data are contained within the article.

Acknowledgments

The authors acknowledge the financial support from the National Research Council of Canada (NSERC). The authors are very grateful for the prolific environment provided by their research centers, e.g., the ReSMiQ, the Quebec Network for Research on Protein Function, Engineering, and Applications—PROTEO, the Research Center Dedicated to the Development, Study and Use of New Materials—CERMA, the Quebec Center for Advanced Materials—QCAM and the Vision Health Research Network. Authors are grateful to CMC Microsystems for their support related to softwares used in this project. EB is a research scholar from the Fonds de Recherche du Québec—Santé.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Tavakolian-Ardakani, Z.; Hosu, O.; Cristea, C.; Mazloum-Ardakani, M.; Marrazza, G. Latest trends in electrochemical sensors for neurotransmitters: A review. Sensors 2019, 19, 2037. [Google Scholar] [CrossRef] [PubMed]
  2. Banerjee, S.; McCracken, S.; Hossain, M.F.; Slaughter, G. Electrochemical detection of neurotransmitters. Biosensors 2020, 10, 101. [Google Scholar] [CrossRef] [PubMed]
  3. Puthongkham, P.; Venton, B.J. Recent advances in fast-scan cyclic voltammetry. Analyst 2020, 145, 1087–1102. [Google Scholar] [CrossRef] [PubMed]
  4. Chauhan, N.; Soni, S.; Agrawal, P.; Balhara, Y.P.S.; Jain, U. Recent advancement in nanosensors for neurotransmitters detection: Present and future perspective. Process Biochem. 2020, 91, 241–259. [Google Scholar] [CrossRef]
  5. Liu, R.; Feng, Z.Y.; Li, D.; Jin, B.; Lan, Y.; Meng, L.Y. Recent trends in carbon-based microelectrodes as electrochemical sensors for neurotransmitter detection: A review. TrAC Trends Anal. Chem. 2022, 148, 116541. [Google Scholar] [CrossRef]
  6. Pradhan, T.; Jung, H.S.; Jang, J.H.; Kim, T.W.; Kang, C.; Kim, J.S. Chemical sensing of neurotransmitters. Chem. Soc. Rev. 2014, 43, 4684–4713. [Google Scholar] [CrossRef]
  7. Si, B.; Song, E. Recent advances in the detection of neurotransmitters. Chemosensors 2018, 6, 1. [Google Scholar] [CrossRef]
  8. Niyonambaza, S.D.; Kumar, P.; Xing, P.; Mathault, J.; De Koninck, P.; Boisselier, E.; Boukadoum, M.; Miled, A. A review of neurotransmitters sensing methods for neuro-engineering research. Appl. Sci. 2019, 9, 4719. [Google Scholar] [CrossRef]
  9. Wu, Z.; Lin, D.; Li, Y. Pushing the frontiers: Tools for monitoring neurotransmitters and neuromodulators. Nat. Rev. Neurosci. 2022, 23, 257–274. [Google Scholar] [CrossRef]
  10. Da, Y.; Luo, S.; Tian, Y. Real-time monitoring of neurotransmitters in the brain of living animals. ACS Appl. Mater. Interfaces 2022, 15, 138–157. [Google Scholar] [CrossRef]
  11. Tůma, P. Progress in on-line, at-line, and in-line coupling of sample treatment with capillary and microchip electrophoresis over the past 10 years: A review. Anal. Chim. Acta 2023, 1261, 341249. [Google Scholar] [CrossRef] [PubMed]
  12. Mecca, A.P. AD molecular: Molecular imaging of Alzheimer’s disease: PET imaging of neurotransmitter systems. Prog. Mol. Biol. Transl. Sci. 2019, 165, 139–165. [Google Scholar] [PubMed]
  13. Tiepolt, S.; Meyer, P.M.; Patt, M.; Deuther-Conrad, W.; Hesse, S.; Barthel, H.; Sabri, O. PET imaging of cholinergic neurotransmission in neurodegenerative disorders. J. Nucl. Med. 2022, 63, 33S–44S. [Google Scholar] [CrossRef] [PubMed]
  14. Ceccarini, J.; Liu, H.; Van Laere, K.; Morris, E.D.; Sander, C.Y. Methods for quantifying neurotransmitter dynamics in the living brain with PET imaging. Front. Physiol. 2020, 11, 792. [Google Scholar] [CrossRef] [PubMed]
  15. Fontana, I.C.; Bongarzone, S.; Gee, A.; Souza, D.O.; Zimmer, E.R. PET imaging as a tool for assessing COVID-19 brain changes. Trends Neurosci. 2020, 43, 935–938. [Google Scholar] [CrossRef] [PubMed]
  16. Dukart, J.; Holiga, S.; Rullmann, M.; Lanzenberger, R.; Hawkins, P.C.; Mehta, M.A.; Hesse, S.; Barthel, H.; Sabri, O.; Jech, R.; et al. JuSpace: A Tool for Spatial Correlation Analyses of Magnetic Resonance Imaging Data with Nuclear Imaging Derived Neurotransmitter Maps; Technical report; Wiley Online Library: Hoboken, NJ, USA, 2021. [Google Scholar]
  17. Sander, C.Y.; Hansen, H.D.; Wey, H.Y. Advances in simultaneous PET/MR for imaging neuroreceptor function. J. Cereb. Blood Flow Metab. 2020, 40, 1148–1166. [Google Scholar] [CrossRef] [PubMed]
  18. Koush, Y.; Rothman, D.L.; Behar, K.L.; de Graaf, R.A.; Hyder, F. Human brain functional MRS reveals interplay of metabolites implicated in neurotransmission and neuroenergetics. J. Cereb. Blood Flow Metab. 2022, 42, 911–934. [Google Scholar] [CrossRef]
  19. Rothman, D.L.; de Graaf, R.A.; Hyder, F.; Mason, G.F.; Behar, K.L.; De Feyter, H.M. In vivo 13C and 1H-[13C] MRS studies of neuroenergetics and neurotransmitter cycling, applications to neurological and psychiatric disease and brain cancer. NMR Biomed. 2019, 32, e4172. [Google Scholar] [CrossRef]
  20. Persson, J.; Wall, A.; Weis, J.; Gingnell, M.; Antoni, G.; Lubberink, M.; Bodén, R. Inhibitory and excitatory neurotransmitter systems in depressed and healthy: A positron emission tomography and magnetic resonance spectroscopy study. Psychiatry Res. Neuroimaging 2021, 315, 111327. [Google Scholar] [CrossRef]
  21. Wang, H.X.; Chen, Y.; Haque, Z.; de Veer, M.; Egan, G.; Wang, B. Sialylated milk oligosaccharides alter neurotransmitters and brain metabolites in piglets: An In vivo magnetic resonance spectroscopic (MRS) study. Nutr. Neurosci. 2021, 24, 885–895. [Google Scholar] [CrossRef]
  22. Park, Y.W.; Deelchand, D.K.; Joers, J.M.; Kumar, A.; Alvear, A.B.; Moheet, A.; Seaquist, E.R.; Öz, G. Monitoring the neurotransmitter response to glycemic changes using an advanced magnetic resonance spectroscopy protocol at 7T. Front. Neurol. 2021, 12, 698675. [Google Scholar] [CrossRef] [PubMed]
  23. Venton, B.J.; Cao, Q. Fundamentals of fast-scan cyclic voltammetry for dopamine detection. Analyst 2020, 145, 1158–1168. [Google Scholar] [CrossRef] [PubMed]
  24. Li, J.; Liu, Y.; Yuan, L.; Zhang, B.; Bishop, E.S.; Wang, K.; Tang, J.; Zheng, Y.Q.; Xu, W.; Niu, S.; et al. A tissue-like neurotransmitter sensor for the brain and gut. Nature 2022, 606, 94–101. [Google Scholar] [CrossRef] [PubMed]
  25. Hu, K.; Wang, D.; Zhou, M.; Bae, J.H.; Yu, Y.; Xin, H.; Mirkin, M.V. Ultrasensitive detection of dopamine with carbon nanopipets. Anal. Chem. 2019, 91, 12935–12941. [Google Scholar] [CrossRef] [PubMed]
  26. Bala, K.; Sharma, D.; Gupta, N. Carbon-Nanotube-Based Materials for Electrochemical Sensing of the Neurotransmitter Dopamine. ChemElectroChem 2019, 6, 274–288. [Google Scholar] [CrossRef]
  27. Rizalputri, L.N.; Anshori, I.; Handayani, M.; Gumilar, G.; Septiani, N.L.W.; Hartati, Y.W.; Annas, M.S.; Purwidyantri, A.; Prabowo, B.A.; Yuliarto, B. Facile and controllable synthesis of monodisperse gold nanoparticle bipyramid for electrochemical dopamine sensor. Nanotechnology 2022, 34, 055502. [Google Scholar] [CrossRef] [PubMed]
  28. de Pontes Medrades, J.; Maciel, C.C.; de Souza Moraes, A.; de Lima Leite, F.; Ferreira, M. Flavin adenine dinucleotide functionalized gold nanoparticles for the electrochemical detection of dopamine. Sens. Actuators Rep. 2022, 4, 100085. [Google Scholar] [CrossRef]
  29. Chou, J.A.; Chung, C.L.; Ho, P.C.; Luo, C.H.; Tsai, Y.H.; Wu, C.K.; Kuo, C.W.; Hsiao, Y.S.; Yu, H.h.; Chen, P. Organic electrochemical transistors/SERS-active hybrid biosensors featuring gold nanoparticles immobilized on thiol-functionalized PEDOT films. Front. Chem. 2019, 7, 281. [Google Scholar] [CrossRef]
  30. Lu, L.; Zhou, Y.; Zheng, T.; Tian, Y. SERS and EC dual-mode detection for dopamine based on WO3-SnO2 nanoflake arrays. Nano Res. 2023, 16, 4049–4054. [Google Scholar] [CrossRef]
  31. Ren, L.; Oleinick, A.; Svir, I.; Amatore, C.; Ewing, A.G. Amperometric measurements and dynamic models reveal a mechanism for how zinc alters neurotransmitter release. Angew. Chem. Int. Ed. 2020, 59, 3083–3087. [Google Scholar] [CrossRef]
  32. Wang, Y.; Ewing, A. Electrochemical quantification of neurotransmitters in single live cell vesicles shows exocytosis is predominantly partial. ChemBioChem 2021, 22, 807–813. [Google Scholar] [CrossRef]
  33. Bermingham, K.P.; Doran, M.M.; Bolger, F.B.; Lowry, J.P. Design optimisation and characterisation of an amperometric glutamate oxidase-based composite biosensor for neurotransmitter l-glutamic acid. Anal. Chim. Acta 2022, 1224, 340205. [Google Scholar] [CrossRef] [PubMed]
  34. Bodur, O.C.; Dinç, S.; Özmen, M.; Arslan, F. A sensitive amperometric detection of neurotransmitter acetylcholine using carbon dot-modified carbon paste electrode. Biotechnol. Appl. Biochem. 2021, 68, 20–29. [Google Scholar] [CrossRef] [PubMed]
  35. Akbıyık, M.A.; Bodur, O.C.; Keskin, M.; Kara, M.; Dinç, S.; Arslan, H.; Özmen, M.; Arslan, F. A Sensitive Amperometric Biosensor Based on Carbon Dot 3-Chloropropyl-trimethoxysilane Modified Electrode for Detection of Neurotransmitter Dopamine. J. Electrochem. Soc. 2023, 170, 037517. [Google Scholar] [CrossRef]
  36. Xu, P.; Rapidi, H.I.M.; Ahmed, S.; Abel, D.K.; Garcia, K.J.; Chen, R.; Iwai, N.T.; Shen, M. PEDOT/PVC-modified amperometric carbon electrodes for acetylcholine detection. Chem. Commun. 2022, 58, 13218–13221. [Google Scholar] [CrossRef] [PubMed]
  37. Qiao, J.; Wang, Y.; Dong, S.; Liang, Q.; Shao, S. Au Nanoparticles-Decorated BiOI Nanosheet Arrays for Cathodic Photoelectrochemical Dopamine Sensors. ACS Appl. Nano Mater. 2023, 6, 5664–5674. [Google Scholar] [CrossRef]
  38. Moldovan, N.; Blaga, I.I.; Billa, S.; Hossain, I.; Gong, C.; Jones, C.E.; Murray, T.A.; Divan, R.; Siddiqui, S.; Arumugan, P.U. Brain-Implant Microfluidic Probe for in vivo Detection of Glutamate and GABA Neurotransmitters. Sens. Actuators B Chem. 2021, 337. [Google Scholar] [CrossRef]
  39. Massé, I.O.; Moquin, L.; Provost, C.; Guay, S.; Gratton, A.; De Beaumont, L. A novel and translational rat model of concussion combining force and rotation with in vivo cerebral microdialysis. JoVE (J. Vis. Exp.) 2019, e59585. [Google Scholar] [CrossRef]
  40. Furness, A.M.; Pal, R.; Michealis, E.K.; Lunte, C.E.; Lunte, S.M. Neurochemical investigation of multiple locally induced seizures using microdialysis sampling: Epilepsy effects on glutamate release. Brain Res. 2019, 1722, 146360. [Google Scholar] [CrossRef]
  41. Zhang, S.J.; Kang, K.; Niu, L.M.; Kang, W.J. Electroanalysis of neurotransmitters via 3D gold nanoparticles and a graphene composite coupled with a microdialysis device. J. Electroanal. Chem. 2019, 834, 249–257. [Google Scholar] [CrossRef]
  42. Dahchour, A.; Ward, R.J. Changes in brain dopamine extracellular concentration after ethanol administration; rat microdialysis studies. Alcohol Alcohol. 2022, 57, 165–175. [Google Scholar] [CrossRef] [PubMed]
  43. van Mever, M.; Segers, K.; Drouin, N.; Guled, F.; Vander Heyden, Y.; Van Eeckhaut, A.; Hankemeier, T.; Ramautar, R. Direct profiling of endogenous metabolites in rat brain microdialysis samples by capillary electrophoresis-mass spectrometry with on-line preconcentration. Microchem. J. 2020, 156, 104949. [Google Scholar] [CrossRef]
  44. Tůma, P.; Sommerová, B.; Daněček, V. On-line coupling of capillary electrophoresis with microdialysis for determining saccharides in dairy products and honey. Food Chem. 2020, 316, 126362. [Google Scholar] [CrossRef] [PubMed]
  45. Creative Proteomics. Neurotransmitters Analysis Service. 2023. Available online: https://metabolomics.creative-proteomics.com/neurotransmitters-analysis-service.htm (accessed on 26 September 2023).
  46. McLaughlin, N.; Bielinski, T.M.; Tressler, C.M.; Barton, E.; Glunde, K.; Stumpo, K.A. Pneumatically sprayed gold nanoparticles for mass spectrometry imaging of neurotransmitters. J. Am. Soc. Mass Spectrom. 2020, 31, 2452–2461. [Google Scholar] [CrossRef] [PubMed]
  47. Lendor, S.; Hassani, S.A.; Boyaci, E.; Singh, V.; Womelsdorf, T.; Pawliszyn, J. Solid phase microextraction-based miniaturized probe and protocol for extraction of neurotransmitters from brains in vivo. Anal. Chem. 2019, 91, 4896–4905. [Google Scholar] [CrossRef] [PubMed]
  48. Le, T.H.; Lee, H.J.; Kim, J.H.; Park, S.J. Detection of ferric ions and catecholamine neurotransmitters via highly fluorescent heteroatom co-doped carbon dots. Sensors 2020, 20, 3470. [Google Scholar] [CrossRef]
  49. Jafarinejad, S.; Bigdeli, A.; Ghazi-Khansari, M.; Sasanpour, P.; Hormozi-Nezhad, M.R. Identification of catecholamine neurotransmitters using a fluorescent electronic tongue. ACS Chem. Neurosci. 2019, 11, 25–33. [Google Scholar] [CrossRef] [PubMed]
  50. Abbasi-Moayed, S.; Hormozi-Nezhad, M.R.; Maaza, M. A multichannel single-well sensor array for rapid and visual discrimination of catecholamine neurotransmitters. Sens. Actuators B Chem. 2019, 296, 126691. [Google Scholar] [CrossRef]
  51. Abbasi-Moayed, S.; Bigdeli, A.; Hormozi-Nezhad, M.R. Application of NaYF4: Yb/Er/Tm UCNPs in array-based sensing of neurotransmitters: From a single particle to a multichannel sensor array. ACS Appl. Mater. Interfaces 2020, 12, 52976–52982. [Google Scholar] [CrossRef]
  52. Bazany-Rodríguez, I.J.; Salomón-Flores, M.K.; Viviano-Posadas, A.O.; García-Eleno, M.A.; Barroso-Flores, J.; Martínez-Otero, D.; Dorazco-González, A. Chemosensing of neurotransmitters with selectivity and naked eye detection of l-DOPA based on fluorescent Zn (ii)-terpyridine bearing boronic acid complexes. Dalton Trans. 2021, 50, 4255–4269. [Google Scholar] [CrossRef]
  53. Zeng, S.; Wang, S.; Xie, X.; Yang, S.H.; Fan, J.h.; Nie, Z.; Huang, Y.; Wang, H.H. Live-cell imaging of neurotransmitter release with a cell-surface-anchored DNA-nanoprism fluorescent sensor. Anal. Chem. 2020, 92, 15194–15201. [Google Scholar] [CrossRef] [PubMed]
  54. Meissner, G.W.; Nern, A.; Singer, R.H.; Wong, A.M.; Malkesman, O.; Long, X. Mapping neurotransmitter identity in the whole-mount Drosophila brain using multiplex high-throughput fluorescence in situ hybridization. Genetics 2019, 211, 473–482. [Google Scholar] [CrossRef] [PubMed]
  55. Feng, J.; Zhang, C.; Lischinsky, J.E.; Jing, M.; Zhou, J.; Wang, H.; Zhang, Y.; Dong, A.; Wu, Z.; Wu, H.; et al. A genetically encoded fluorescent sensor for rapid and specific in vivo detection of norepinephrine. Neuron 2019, 102, 745–761. [Google Scholar] [CrossRef] [PubMed]
  56. Wang, Y.; DelRosso, N.V.; Vaidyanathan, T.V.; Cahill, M.K.; Reitman, M.E.; Pittolo, S.; Mi, X.; Yu, G.; Poskanzer, K.E. Accurate quantification of astrocyte and neurotransmitter fluorescence dynamics for single-cell and population-level physiology. Nat. Neurosci. 2019, 22, 1936–1944. [Google Scholar] [CrossRef] [PubMed]
  57. Dinarvand, M.; Elizarova, S.; Daniel, J.; Kruss, S. Imaging of monoamine neurotransmitters with fluorescent nanoscale sensors. ChemPlusChem 2020, 85, 1465–1480. [Google Scholar] [CrossRef] [PubMed]
  58. Zhang, D.; Qian, M.; Yang, X.; Zhang, C.; Qi, H.; Qi, H. Label-Free Electrogenerated Chemiluminescence Aptasensing Method for Highly Sensitive Determination of Dopamine via Target-Induced DNA Conformational Change. Anal. Chem. 2023, 95, 5500–5506. [Google Scholar] [CrossRef]
  59. Li, Z.; Zhu, M.; Li, F.; Li, Z.; Zhao, A.; Haghighatbin, M.A.; Cui, H. Microfluidic paper chip based multicolor chemiluminescence sensing strategy for discrimination of antioxidants. Sens. Actuators Chem. 2023, 393, 134166. [Google Scholar] [CrossRef]
  60. Beigi, S.M.; Khurshid, C.A.; Mesgari, F.; Poursaberi, T.; Hosseini, M. Use of an Electrogenerated Chemiluminescence Sensor Modified with Sm2O3 Nanoparticles/Chitosan for the Analysis of Phenylalanine. Anal. Bioanal. Electrochem. 2020, 12, 141–154. [Google Scholar]
  61. Wang, Y. Preparation of an Electrochemical Luminescence Sensor for Monoamine Neurotransmitter (polydopamine) Detection after Endurance Training. Int. J. Electrochem. Sci. 2020, 15, 1681–1690. [Google Scholar] [CrossRef]
  62. Kong, M.; Jin, P.; Wei, W.; Wang, W.; Qin, H.; Chen, H.; He, J. Covalent organic frameworks (COF-300-AR) with unique catalytic performance in luminol chemiluminescence for sensitive detection of serotonin. Microchem. J. 2021, 160, 105650. [Google Scholar] [CrossRef]
  63. Yang, M.; Wang, L.; Lu, H.; Dong, Q. Advances in MXene-Based Electrochemical (Bio) Sensors for Neurotransmitter Detection. Micromachines 2023, 14, 1088. [Google Scholar] [CrossRef]
  64. Zhang, K.; Wu, H.; Zhang, Y. Recent Development of Electrochemical Detection of Neurotransmitter Dopamine Based on Molecular Imprinting Technique. Int. J. Electrochem. Sci. 2022, 17, 220662. [Google Scholar] [CrossRef]
  65. Xu, K. Silicon electro-optic micro-modulator fabricated in standard CMOS technology as components for all silicon monolithic integrated optoelectronic systems. J. Micromech. Microeng. 2021, 31, 054001. [Google Scholar] [CrossRef]
  66. Sangubotla, R.; Kim, J. Fiber-optic biosensor based on the laccase immobilization on silica-functionalized fluorescent carbon dots for the detection of dopamine and multi-color imaging applications in neuroblastoma cells. Mater. Sci. Eng. C 2021, 122, 111916. [Google Scholar] [CrossRef] [PubMed]
  67. Zhang, Y.; Ding, L.; Zhang, H.; Wang, P.; Li, H. A new optical fiber biosensor for acetylcholine detection based on pH sensitive fluorescent carbon quantum dots. Sens. Actuators B Chem. 2022, 369, 132268. [Google Scholar] [CrossRef]
  68. Zhu, G.; Wang, Y.; Wang, Z.; Singh, R.; Marques, C.; Wu, Q.; Kaushik, B.K.; Jha, R.; Zhang, B.; Kumar, S. Localized plasmon-based multicore fiber biosensor for acetylcholine detection. IEEE Trans. Instrum. Meas. 2021, 71, 1–9. [Google Scholar] [CrossRef]
  69. Zheng, D.; Pisano, F.; Collard, L.; Balena, A.; Pisanello, M.; Spagnolo, B.; Mach-Batlle, R.; Tantussi, F.; Carbone, L.; De Angelis, F.; et al. Toward Plasmonic Neural Probes: SERS Detection of Neurotransmitters through Gold-Nanoislands-Decorated Tapered Optical Fibers with Sub-10 nm Gaps. Adv. Mater. 2023, 35, 2200902. [Google Scholar] [CrossRef] [PubMed]
  70. Ejdrup, A.L.; Wellbourne-Wood, J.; Dreyer, J.K.; Guldhammer, N.; Lycas, M.D.; Gether, U.; Hall, B.J.; Sørensen, G. Within-Mice Comparison of Microdialysis and Fiber Photometry-Recorded Dopamine Biosensor during Amphetamine Response. ACS Chem. Neurosci. 2023, 14, 1622–1630. [Google Scholar] [CrossRef]
  71. Hariharan, A.; Kurnoothala, R.; Chinthakayala, S.K.; Vishnubhatla, K.C.; Vadlamudi, P. SERS of Dopamine: Computational and experimental studies. Spectrochim. Acta Part A Mol. Biomol. Spectrosc. 2021, 260, 119962. [Google Scholar] [CrossRef]
  72. Hariharan, A.; Vadlamudi, P. SERS of Epinephrine: A computational and experimental study. J. Mol. Struct. 2021, 1246, 131163. [Google Scholar] [CrossRef]
  73. Hariharan, A.; Vadlamudi, P. SERS of norepinephrine: A computational and experimental study. Mater. Today Commun. 2021, 27, 102429. [Google Scholar] [CrossRef]
  74. Oliveira, T.A.; Martin, C.S.; Rubira, R.J.; de Barros, A.; Mazali, I.O.; Constantino, C.J. Influence of l-Dopa adsorption time and concentration on Au nanorods aggregation for SERS quantitative analysis. Curr. Appl. Phys. 2023, 54, 31–37. [Google Scholar] [CrossRef]
  75. El-Said, W.A.; Alshitari, W.; Choi, J.w. Controlled fabrication of gold nanobipyramids/polypyrrole for shell-isolated nanoparticle-enhanced Raman spectroscopy to detect γ-aminobutyric acid. Spectrochim. Acta Part A Mol. Biomol. Spectrosc. 2020, 229, 117890. [Google Scholar] [CrossRef] [PubMed]
  76. Ren, X.; Zhang, Q.; Yang, J.; Zhang, X.; Zhang, X.; Zhang, Y.; Huang, L.; Xu, C.; Ge, Y.; Chen, H.; et al. Dopamine imaging in living cells and retina by surface-enhanced Raman scattering based on functionalized gold nanoparticles. Anal. Chem. 2021, 93, 10841–10849. [Google Scholar] [CrossRef] [PubMed]
  77. Proniewicz, E.; Tąta, A.; Wójcik, A.; Starowicz, M.; Pacek, J.; Molenda, M. SERS activity and spectroscopic properties of Zn and ZnO nanostructures obtained by electrochemical and green chemistry methods for applications in biology and medicine. Phys. Chem. Chem. Phys. 2020, 22, 28100–28114. [Google Scholar] [CrossRef] [PubMed]
  78. Yucel, N.; Buluş, E.; Bulus, G.S.; Khan, A.; Xhibo, F.; Turan, S.; Qureshi, A.; Kolkar, J.; Yakuphanoglu, F. Synthesis and Characterization of Novel Nanomaterials for SERS Biomedical/Environmental Application. J. Mater. Electron. Devices 2020, 4, 38–43. [Google Scholar]
  79. Eremina, O.E.; Yarenkov, N.R.; Kapitanova, O.O.; Zelenetskaya, A.S.; Smirnov, E.A.; Shekhovtsova, T.N.; Goodilin, E.A.; Veselova, I.A. Molecular Immobilization and Resonant Raman Amplification by Complex-Loaded Enhancers (MIRRACLE) on copper (II)–chitosan–modified SERS-active metallic nanostructured substrates for multiplex determination of dopamine, norepinephrine, and epinephrine. Microchim. Acta 2022, 189, 211. [Google Scholar] [CrossRef] [PubMed]
  80. Phung, V.D.; Kook, J.K.; Lee, S.W. Hierarchical Au nanoclusters electrodeposited on amine-terminated ITO glass as a SERS-active substrate for the reliable and sensitive detection of serotonin in a Tris-HCl buffer solution. Dalton Trans. 2019, 48, 16026–16033. [Google Scholar] [CrossRef]
  81. Choi, Y.; Jeon, C.S.; Kim, K.B.; Kim, H.J.; Pyun, S.H.; Park, Y.M. Quantitative detection of dopamine in human serum with surface-enhanced Raman scattering (SERS) of constrained vibrational mode. Talanta 2023, 260, 124590. [Google Scholar] [CrossRef]
  82. Lu, D.; Fan, M.; Cai, R.; Huang, Z.; You, R.; Huang, L.; Feng, S.; Lu, Y. Silver nanocube coupling with a nanoporous silver film for dual-molecule recognition based ultrasensitive SERS detection of dopamine. Analyst 2020, 145, 3009–3016. [Google Scholar] [CrossRef]
  83. Lee, W.; Kang, B.H.; Yang, H.; Park, M.; Kwak, J.H.; Chung, T.; Jeong, Y.; Kim, B.K.; Jeong, K.H. Spread spectrum SERS allows label-free detection of attomolar neurotransmitters. Nat. Commun. 2021, 12, 159. [Google Scholar] [CrossRef] [PubMed]
  84. Tezcan, T.; Hsu, C.H. High-sensitivity SERS based sensing on the labeling side of glass slides using low branched gold nanoparticles prepared with surfactant-free synthesis. RSC Adv. 2020, 10, 34290–34298. [Google Scholar] [CrossRef] [PubMed]
  85. Eremina, O.E.; Kapitanova, O.O.; Medved’ko, A.V.; Zelenetskaya, A.S.; Egorova, B.V.; Shekhovtsova, T.N.; Vatsadze, S.Z.; Veselova, I.A. Plier ligands for trapping neurotransmitters into complexes for sensitive analysis by SERS spectroscopy. Biosensors 2023, 13, 124. [Google Scholar] [CrossRef] [PubMed]
  86. Feng, L.; Li, C.; Wang, L.; Li, J.; Liu, X.; Li, Q.; Luo, S.; Shen, J. Self-Referenced Surface-Enhanced Raman Scattering Nanosubstrate for the Quantitative Detection of Neurotransmitters. ACS Appl. Bio Mater. 2022, 5, 2403–2410. [Google Scholar] [CrossRef] [PubMed]
  87. Dowek, A.; Berge, M.; Prognon, P.; Legrand, F.X.; Larquet, E.; Tfayli, A.; Lê, L.M.M.; Caudron, E. Discriminative and quantitative analysis of norepinephrine and epinephrine by surface-enhanced Raman spectroscopy with gold nanoparticle suspensions. Anal. Bioanal. Chem. 2022, 414, 1163–1176. [Google Scholar] [CrossRef] [PubMed]
  88. Le, T.V.; Park, J.S.; Lee, S.W. Synchronous Fe3+-Enhanced Colorimetric and Liquid SERS-Based Detection of Dopamine Using Core–Shell Plasmonic Nanoparticles. ACS Appl. Nano Mater. 2023, 6, 6726–6738. [Google Scholar] [CrossRef]
  89. Wu, L.; Liu, X.; Zong, S.; Wang, Z.; Cui, Y. A SERS Composite Hydrogel Device for Point-of-Care Analysis of Neurotransmitter in Whole Blood. Biosensors 2023, 13, 611. [Google Scholar] [CrossRef]
  90. Vo, V.T.; Gwon, Y.; Phung, V.D.; Son, Y.D.; Kim, J.H.; Lee, S.W. Ag-Deposited Porous Silicon as a SERS-Active Substrate for the Sensitive Detection of Catecholamine Neurotransmitters. Electron. Mater. Lett. 2021, 17, 292–298. [Google Scholar] [CrossRef]
  91. Nam, W.; Kim, W.; Zhou, W.; You, E.A. A digital SERS sensing platform using 3D nanolaminate plasmonic crystals coupled with Au nanoparticles for accurate quantitative detection of dopamine. Nanoscale 2021, 13, 17340–17349. [Google Scholar] [CrossRef]
  92. Bai, S.; Ma, Y.; Obata, K.; Sugioka, K. Ultraminiaturized Microfluidic Electrochemical Surface-Enhanced Raman Scattering Chip for Analysis of Neurotransmitters Fabricated by Ship-in-a-Bottle Integration. Small Sci. 2023, 3, 2200093. [Google Scholar] [CrossRef]
  93. Chen, W.H.; Wang, W.; Lin, Q.; Grys, D.B.; Niihori, M.; Huang, J.; Hu, S.; de Nijs, B.; Scherman, O.A.; Baumberg, J.J. Plasmonic Sensing Assay for Long-Term Monitoring (PSALM) of Neurotransmitters in Urine. ACS Nanosci. Au 2022, 3, 161–171. [Google Scholar] [CrossRef] [PubMed]
  94. Zhang, T.; Wang, G.; Bao, J.; Liu, C.; Li, W.; Kong, Z.; Sun, X.; Li, J.; Lu, R. Fabrication of an Ag-based SERS nanotag for histamine quantitative detection. Talanta 2023, 256, 124256. [Google Scholar] [CrossRef] [PubMed]
  95. Wu, H.Y.; Lin, H.C.; Liu, Y.H.; Chen, K.L.; Wang, Y.H.; Sun, Y.S.; Hsu, J.C. Highly sensitive, robust, and recyclable TiO2/AgNP substrate for SERS detection. Molecules 2022, 27, 6755. [Google Scholar] [CrossRef] [PubMed]
  96. Do, P.Q.T.; Huong, V.T.; Phuong, N.T.T.; Nguyen, T.H.; Ta, H.K.T.; Ju, H.; Phan, T.B.; Phung, V.D.; Trinh, K.T.L.; Tran, N.H.T. The highly sensitive determination of serotonin by using gold nanoparticles (Au NPs) with a localized surface plasmon resonance (LSPR) absorption wavelength in the visible region. RSC Adv. 2020, 10, 30858–30869. [Google Scholar] [CrossRef] [PubMed]
  97. Dowek, A.; Voisin, F.; Le, L.; Tan, C.; Mallet, J.; Carn, F.; Caudron, E. Self-assembly of gold nanoparticles by chitosan for improved epinephrine detection using a portable surface enhanced Raman scattering device. Talanta 2023, 251, 123752. [Google Scholar] [CrossRef] [PubMed]
  98. Wang, W.; Zhang, B.; Zhang, Y.; Ma, P.; Wang, X.; Sun, Y.; Song, D.; Fei, Q. Colorimetry and SERS dual-mode sensing of serotonin based on functionalized gold nanoparticles. Spectrochim. Acta Part A Mol. Biomol. Spectrosc. 2021, 261, 120057. [Google Scholar] [CrossRef] [PubMed]
  99. Proniewicz, E.; Tąta, A.; Starowicz, M.; Szkudlarek, A.; Pacek, J.; Molenda, M.; Kuśtrowski, P. Ions-free electrochemically synthetized in aqueous media flake-like CuO nanostructures as SERS reproducible substrates for the detection of neurotransmitters. Spectrochim. Acta Part A Mol. Biomol. Spectrosc. 2019, 215, 24–33. [Google Scholar] [CrossRef]
  100. Hussein, M.A.; El-Said, W.A.; Abu-Zied, B.M.; Choi, J.W. Nanosheet composed of gold nanoparticle/graphene/epoxy resin based on ultrasonic fabrication for flexible dopamine biosensor using surface-enhanced Raman spectroscopy. Nano Converg. 2020, 7, 1–12. [Google Scholar] [CrossRef]
  101. Vander Ende, E.; Bourgeois, M.R.; Henry, A.I.; Chávez, J.L.; Krabacher, R.; Schatz, G.C.; Van Duyne, R.P. Physicochemical trapping of neurotransmitters in polymer-mediated gold nanoparticle aggregates for surface-enhanced Raman spectroscopy. Anal. Chem. 2019, 91, 9554–9562. [Google Scholar] [CrossRef]
  102. Vo, V.T.; Phung, V.D.; Lee, S.W. Nanosilver-embedded silicon nanowires as a SERS-active substrate for the ultrasensitive detection of monoamine neurotransmitters. Surf. Interfaces 2021, 25, 101181. [Google Scholar] [CrossRef]
  103. Choi, J.H.; Kim, T.H.; El-Said, W.A.; Lee, J.H.; Yang, L.; Conley, B.; Choi, J.W.; Lee, K.B. In situ detection of neurotransmitters from stem cell-derived neural interface at the single-cell level via graphene-hybrid SERS nanobiosensing. Nano Lett. 2020, 20, 7670–7679. [Google Scholar] [CrossRef] [PubMed]
  104. Li, P.; Zhou, B.; Ge, M.; Jing, X.; Yang, L. Metal coordination induced SERS nanoprobe for sensitive and selective detection of histamine in serum. Talanta 2022, 237, 122913. [Google Scholar] [CrossRef] [PubMed]
  105. Zhu, H.; Lussier, F.; Ducrot, C.; Bourque, M.J.; Spatz, J.P.; Cui, W.; Yu, L.; Peng, W.; Trudeau, L.E.; Bazuin, C.G.; et al. Block copolymer brush layer-templated gold nanoparticles on nanofibers for surface-enhanced Raman scattering optophysiology. ACS Appl. Mater. Interfaces 2019, 11, 4373–4384. [Google Scholar] [CrossRef] [PubMed]
  106. Niyonambaza, S.D.; Boisselier, E.; Boukadoum, M.; Miled, A. Microfluidic Spectrophotometer for Neurotransmitter Detection Based on Gold Nanoparticles: Preliminary Results. In Proceedings of the 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Honolulu, HI, USA, 18–21 July 2018; pp. 3854–3857. [Google Scholar] [CrossRef]
  107. Niyonambaza, S.D.; Koudrina, A.; DeRosa, M.C.; Boukadoum, M.; Miled, A.; Boisselier, E. Aptamer-Modified Ultrastable Gold Nanoparticles for Dopamine Detection. IEEE Sens. J. 2021, 21, 2517–2525. [Google Scholar] [CrossRef]
  108. Niyonambaza, S.D.; Lachance, G.P.; Boisselier, É.; Boukadoum, M.; Miled, A. Concept of a Crossed Czerny–Turner Spectrometer With an Integrated Automatic Sampling System for Biodetection Using Ultrastable Gold Nanoparticles. IEEE Sens. J. 2023, 23, 14819–14825. [Google Scholar] [CrossRef]
  109. Lachance, G.P.; Bouffard, L.; Boisselier, É.; Miled, A.; Boukadoum, M. Assessment of a Grism- Based Spectrometer Design for Neurotransmitter Detection. In Proceedings of the 2020 27th IEEE International Conference on Electronics, Circuits and Systems (ICECS), Glasgow, UK, 23–25 November 2020; pp. 1–4. [Google Scholar] [CrossRef]
  110. Lachance, G.P.; Boisselier, É.; Boukadoum, M.; Miled, A. Assessment of a grism-based spectrometer design for neurotransmitter detection: Preliminary results. In Nanoscale Imaging, Sensing, and Actuation for Biomedical Applications XVIII; Fixler, D., Goldys, E.M., Wachsmann-Hogiu, S., Eds.; International Society for Optics and Photonics, SPIE: Bellingham, MA, USA, 2021; Volume 11658, p. 116580C. [Google Scholar] [CrossRef]
  111. Lachance, G.P.; Soulard, G.; Bouffard, L.; Boisselier, É.; Boukadoum, M.; Miled, A. Colorimetric Sensing System for Neurotransmitter Detection Based on Multi-technologies Architecture. In Proceedings of the 2021 28th IEEE International Conference on Electronics, Circuits, and Systems (ICECS), Dubai, United Arab Emirates, 28 November–1 December2021; pp. 1–4. [Google Scholar] [CrossRef]
  112. Lachance, G.P.; Boisselier, É.; Boukadoum, M.; Miled, A. Molecular sensing system based on multi-technologies architecture. In Optical Diagnostics and Sensing XXII: Toward Point-of-Care Diagnostics; Coté, G.L., Ed.; International Society for Optics and Photonics, SPIE: Bellingham, MA, USA, 2022; Volume 11968, p. 1196807. [Google Scholar] [CrossRef]
  113. Lachance, G.P.; Boisselier, É.; Boukadoum, M.; Miled, A. Towards an advanced neurotechnological system: Colorimetric sensing with a novel grism-based spectrometer, functionalized gold nanoparticles and a heterogeneous embedded system. Philos. Trans. R. Soc. A 2022, 380, 20210016. [Google Scholar] [CrossRef] [PubMed]
  114. Vaska, P.; Woody, C.; Schlyer, D.; Shokouhi, S.; Stoll, S.; Pratte, J.F.; O’Connor, P.; Junnarkar, S.; Rescia, S.; Yu, B.; et al. RatCAP: Miniaturized head-mounted PET for conscious rodent brain imaging. IEEE Trans. Nucl. Sci. 2004, 51, 2718–2722. [Google Scholar] [CrossRef]
  115. Massari, R.; D’elia, A.; Soluri, A. Preliminary results on a small animal SPECT system based on H13700 PSMPT coupled with CRY018 array. Nucl. Instruments Methods Phys. Res. Sect. A Accel. Spectrometers Detect. Assoc. Equip. 2019, 940, 296–301. [Google Scholar] [CrossRef]
  116. Rim, S.S.; Mysoor, N.R.; Carnes, S.R. Miniature magnetic resonance spectrometers. In Proceedings of the 16th DASC. AIAA/IEEE Digital Avionics Systems Conference, Reflections to the Future, Proceedings, Irvine, CA, USA, 30 October 1997; Volume 1, pp. 2–14. [Google Scholar]
  117. ISO 9241-11:2018; Ergonomics of Human-System Interaction—Part 11: Usability: Definitions and Concepts. International Organization for Standardization: Geneva, Switzerland, 2020.
  118. The British Columbia Society for the Prevention of Cruelty to Animals. Canada Bans Cosmetic Testing and Starts to Phase Out Toxicity Testing on Animals. 2023. Available online: https://spca.bc.ca/ways-to-help/take-action/animals-in-science/canada-bans-cosmetic-testing-on-animals/ (accessed on 17 August 2023).
  119. The Government of Canada. Food and Drugs Act, R.S.C. 1985, c. F-27. 2023. Available online: https://laws-lois.justice.gc.ca/eng/acts/f-27/FullText.html (accessed on 17 August 2023).
  120. The Government of Canada. Strengthening Environmental Protection for a Healthier Canada Act, S.C. 2023, c. 12. 2023. Available online: https://laws-lois.justice.gc.ca/eng/AnnualStatutes/2023_12/FullText.html (accessed on 17 August 2023).
  121. The Government of Canada. Canadian Environmental Protection Act, 1999, S.C. 1999, c. 33. 2023. Available online: https://laws-lois.justice.gc.ca/eng/acts/c-15.31/FullText.html (accessed on 17 August 2023).
  122. The Government of the United Kingdoms. Guidance on the Operation of the Animals (Scientific Procedures) Act 1986. 2017. Available online: https://www.gov.uk/guidance/guidance-on-the-operation-of-the-animals-scientific-procedures-act-1986#full-publication-update-history (accessed on 17 August 2023).
  123. Louhimies, S. Directive 86/609/EEC on the protection of animals used for experimental and other scientific purposes. Altern. Lab. Anim. 2002, 30, 217–219. [Google Scholar] [CrossRef]
  124. Official Journal of the European Union. EC Directive 2003/15/EC of the European Parliament and of the Council of 27 February 2003 Amending Council Directive 76/768/EEC on the Approximation of the Laws of the Member States Relating to Cosmetic Products. 2003. Available online: https://eur-lex.europa.eu/LexUriServ/LexUriServ.do?uri=OJ:L:2003:066:0026:0035:en:PDF#:~:text=The%20Protocol%20on%20protection%20and,policies%2C%20in%20particular%20with%20regard (accessed on 17 August 2023).
  125. Meigs, L.; Smirnova, L.; Rovida, C.; Leist, M.; Hartung, T. Animal testing and its alternatives—The most important omics is economics. ALTEX-Altern. Anim. Exp. 2018, 35, 275–305. [Google Scholar] [CrossRef]
  126. Official Journal of the European Union. REGULATION (EC) No 1223/2009 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 30 November 2009 on Cosmetic Products. 2009. Available online: https://health.ec.europa.eu/system/files/2016-11/cosmetic_1223_2009_regulation_en_0.pdf (accessed on 17 August 2023).
  127. United States Department or Agriculture. Animal Welfare Act and Animal Welfare Regulations. 2023. Available online: https://www.aphis.usda.gov/animal_welfare/downloads/AC_BlueBook_AWA_508_comp_version.pdf (accessed on 17 August 2023).
  128. The Humane Society of the United States. 2023. Available online: https://www.humanesociety.org/resources/timeline-cosmetics-testing-animals (accessed on 17 August 2023).
  129. Schlabach, J. 900 Companies Support Humane Cosmetics Act to End Animal Testing. Global Cosmetic Industry. 2020. Available online: https://www.gcimagazine.com/brands-products/news/news/21874267/900-companies-support-humane-cosmetics-act-to-end-animal-testing (accessed on 17 August 2023).
  130. Van Norman, G.A. Limitations of animal studies for predicting toxicity in clinical trials: Is it time to rethink our current approach? JACC Basic Transl. Sci. 2019, 4, 845–854. [Google Scholar] [CrossRef] [PubMed]
  131. Robinson, N.B.; Krieger, K.; Khan, F.M.; Huffman, W.; Chang, M.; Naik, A.; Yongle, R.; Hameed, I.; Krieger, K.; Girardi, L.N.; et al. The current state of animal models in research: A review. Int. J. Surg. 2019, 72, 9–13. [Google Scholar] [CrossRef] [PubMed]
  132. Voelkl, B.; Altman, N.S.; Forsman, A.; Forstmeier, W.; Gurevitch, J.; Jaric, I.; Karp, N.A.; Kas, M.J.; Schielzeth, H.; Van de Casteele, T.; et al. Reproducibility of animal research in light of biological variation. Nat. Rev. Neurosci. 2020, 21, 384–393. [Google Scholar] [CrossRef] [PubMed]
  133. Farrell, G.; Schattenberg, J.M.; Leclercq, I.; Yeh, M.M.; Goldin, R.; Teoh, N.; Schuppan, D. Mouse models of nonalcoholic steatohepatitis: Toward optimization of their relevance to human nonalcoholic steatohepatitis. Hepatology 2019, 69, 2241–2257. [Google Scholar] [CrossRef] [PubMed]
  134. Lassmann, H. Pathology of inflammatory diseases of the nervous system: Human disease versus animal models. Glia 2020, 68, 830–844. [Google Scholar] [CrossRef]
  135. Cope, P.; Ourradi, K.; Li, Y.; Sharif, M. Models of osteoarthritis: The good, the bad and the promising. Osteoarthr. Cartil. 2019, 27, 230–239. [Google Scholar] [CrossRef] [PubMed]
  136. Winship, I.R.; Dursun, S.M.; Baker, G.B.; Balista, P.A.; Kandratavicius, L.; Maia-de Oliveira, J.P.; Hallak, J.; Howland, J.G. An overview of animal models related to schizophrenia. Can. J. Psychiatry 2019, 64, 5–17. [Google Scholar] [CrossRef] [PubMed]
  137. ATLA. Alternatives to Laboratory Animals Journal. 2023. Available online: https://journals.sagepub.com/description/ATL (accessed on 17 August 2023).
  138. ALTEX. Alternatives to Animal Experimentation Journal. 2023. Available online: https://www.altex.org/index.php/altex (accessed on 17 August 2023).
  139. ADEBiotech. A Transdisciplinary Conference on Alternative Technologies and Models (NAMs) to Reduce the Use of Laboratory Animals in Industry. 2023. Available online: https://asso.adebiotech.org/alternatives-to-animal-experimentation/ (accessed on 17 August 2023).
  140. Silva, R.J.; Tamburic, S. A state-of-the-art review on the alternatives to animal testing for the safety assessment of cosmetics. Cosmetics 2022, 9, 90. [Google Scholar] [CrossRef]
  141. Andersen, M.E.; McMullen, P.D.; Phillips, M.B.; Yoon, M.; Pendse, S.N.; Clewell, H.J.; Hartman, J.K.; Moreau, M.; Becker, R.A.; Clewell, R.A. Developing context appropriate toxicity testing approaches using new alternative methods (NAMs). ALTEX-Altern. Anim. Exp. 2019, 36, 523–534. [Google Scholar] [CrossRef]
  142. Punt, A.; Bouwmeester, H.; Blaauboer, B.J.; Coecke, S.; Hakkert, B.; Hendriks, D.F.; Jennings, P.; Kramer, N.I.; Neuhoff, S.; Masereeuw, R.; et al. New approach methodologies (NAMs) for human-relevant biokinetics predictions: Meeting the paradigm shift in toxicology towards an animal-free chemical risk assessment. ALTEX-Altern. Anim. Exp. 2020, 37, 607–622. [Google Scholar]
  143. Kandarova, H. Alternative methods to animal experimentation and their role in modern toxicology. In Toxicological Risk Assessment and Multi-System Health Impacts from Exposure; Elsevier: Amsterdam, The Netherlands, 2021; pp. 13–22. [Google Scholar]
  144. Ingber, D.E. Is it time for reviewer 3 to request human organ chip experiments instead of animal validation studies? Adv. Sci. 2020, 7, 2002030. [Google Scholar] [CrossRef] [PubMed]
  145. Ingber, D.E. Human organs-on-chips for disease modelling, drug development and personalized medicine. Nat. Rev. Genet. 2022, 23, 467–491. [Google Scholar] [CrossRef] [PubMed]
  146. Ndyabawe, K.; Cipriano, M.; Zhao, W.; Haidekker, M.; Yao, K.; Mao, L.; Kisaalita, W.S. Brain-on-a-chip device for modeling multiregional networks. ACS Biomater. Sci. Eng. 2020, 7, 350–359. [Google Scholar] [CrossRef]
  147. Uzel, S.G.; Amadi, O.C.; Pearl, T.M.; Lee, R.T.; So, P.T.; Kamm, R.D. Simultaneous or sequential orthogonal gradient formation in a 3D cell culture microfluidic platform. Small 2016, 12, 612–622. [Google Scholar] [CrossRef]
  148. Park, J.; Lee, B.K.; Jeong, G.S.; Hyun, J.K.; Lee, C.J.; Lee, S.H. Three-dimensional brain-on-a-chip with an interstitial level of flow and its application as an in vitro model of Alzheimer’s disease. Lab Chip 2015, 15, 141–150. [Google Scholar] [CrossRef] [PubMed]
  149. Yong, Y.; Hughes, C.; Deppmann, C. A microfluidic culture platform to assess axon degeneration. In Axon Degeneration: Methods and Protocols; Humana: New York, NY, USA, 2020; pp. 83–96. [Google Scholar]
  150. Bolognin, S.; Fossépré, M.; Qing, X.; Jarazo, J.; Ščančar, J.; Moreno, E.L.; Nickels, S.L.; Wasner, K.; Ouzren, N.; Walter, J.; et al. 3D cultures of Parkinson’s disease-specific dopaminergic neurons for high content phenotyping and drug testing. Adv. Sci. 2019, 6, 1800927. [Google Scholar] [CrossRef] [PubMed]
  151. Liu, J.; Sternberg, A.R.; Ghiasvand, S.; Berdichevsky, Y. Epilepsy-on-a-chip system for antiepileptic drug discovery. IEEE Trans. Biomed. Eng. 2018, 66, 1231–1241. [Google Scholar] [CrossRef] [PubMed]
  152. Shin, Y.; Choi, S.H.; Kim, E.; Bylykbashi, E.; Kim, J.A.; Chung, S.; Kim, D.Y.; Kamm, R.D.; Tanzi, R.E. Blood–brain barrier dysfunction in a 3D in vitro model of Alzheimer’s disease. Adv. Sci. 2019, 6, 1900962. [Google Scholar] [CrossRef]
  153. Millet, L.J.; Gillette, M.U. New perspectives on neuronal development via microfluidic environments. Trends Neurosci. 2012, 35, 752–761. [Google Scholar] [CrossRef]
  154. Park, J.; Wetzel, I.; Marriott, I.; Dréau, D.; D’Avanzo, C.; Kim, D.Y.; Tanzi, R.E.; Cho, H. A 3D human triculture system modeling neurodegeneration and neuroinflammation in Alzheimer’s disease. Nat. Neurosci. 2018, 21, 941–951. [Google Scholar] [CrossRef]
  155. Majumdar, D.; Gao, Y.; Li, D.; Webb, D.J. Co-culture of neurons and glia in a novel microfluidic platform. J. Neurosci. Methods 2011, 196, 38–44. [Google Scholar] [CrossRef] [PubMed]
  156. Li, Y.T.; Zhang, S.H.; Wang, X.Y.; Zhang, X.W.; Oleinick, A.I.; Svir, I.; Amatore, C.; Huang, W.H. Real-time Monitoring of Discrete Synaptic Release Events and Excitatory Potentials within Self-reconstructed Neuromuscular Junctions. Angew. Chem. 2015, 127, 9445–9450. [Google Scholar] [CrossRef]
  157. Kundu, A.; McCoy, L.; Azim, N.; Nguyen, H.; Didier, C.M.; Ausaf, T.; Sharma, A.D.; Curley, J.L.; Moore, M.J.; Rajaraman, S. Fabrication and characterization of 3D printed, 3D microelectrode arrays for interfacing with a peripheral nerve-on-a-chip. ACS Biomater. Sci. Eng. 2020, 7, 3018–3029. [Google Scholar] [CrossRef] [PubMed]
  158. Hyung, S.; Lee, S.R.; Kim, J.; Kim, Y.; Kim, S.; Kim, H.N.; Jeon, N.L. A 3D disease and regeneration model of peripheral nervous system–on–a–chip. Sci. Adv. 2021, 7, eabd9749. [Google Scholar] [CrossRef] [PubMed]
  159. Yu, Y.; Shamsi, M.H.; Krastev, D.L.; Dryden, M.D.; Leung, Y.; Wheeler, A.R. A microfluidic method for dopamine uptake measurements in dopaminergic neurons. Lab Chip 2016, 16, 543–552. [Google Scholar] [CrossRef] [PubMed]
  160. Senel, M.; Dervisevic, E.; Alhassen, S.; Dervisevic, M.; Alachkar, A.; Cadarso, V.J.; Voelcker, N.H. Microfluidic electrochemical sensor for cerebrospinal fluid and blood dopamine detection in a mouse model of Parkinson’s disease. Anal. Chem. 2020, 92, 12347–12355. [Google Scholar] [CrossRef] [PubMed]
  161. Taylor, A.M.; Rhee, S.W.; Tu, C.H.; Cribbs, D.H.; Cotman, C.W.; Jeon, N.L. Microfluidic multicompartment device for neuroscience research. Langmuir 2003, 19, 1551–1556. [Google Scholar] [CrossRef] [PubMed]
  162. Croushore, C.A.; Supharoek, S.a.; Lee, C.Y.; Jakmunee, J.; Sweedler, J.V. Microfluidic device for the selective chemical stimulation of neurons and characterization of peptide release with mass spectrometry. Anal. Chem. 2012, 84, 9446–9452. [Google Scholar] [CrossRef]
  163. Sharma, A.D.; McCoy, L.; Jacobs, E.; Willey, H.; Behn, J.Q.; Nguyen, H.; Bolon, B.; Curley, J.L.; Moore, M.J. Engineering a 3D functional human peripheral nerve in vitro using the Nerve-on-a-Chip platform. Sci. Rep. 2019, 9, 8921. [Google Scholar] [CrossRef]
  164. Juste-Lanas, Y.; Hervas-Raluy, S.; García-Aznar, J.M.; González-Loyola, A. Fluid flow to mimic organ function in 3D in vitro models. APL Bioeng. 2023, 7, 031501. [Google Scholar] [CrossRef]
  165. Takenaga, S.; Schneider, B.; Erbay, E.; Biselli, M.; Schnitzler, T.; Schöning, M.J.; Wagner, T. Fabrication of biocompatible lab-on-chip devices for biomedical applications by means of a 3D-printing process. Phys. Status Solidi (a) 2015, 212, 1347–1352. [Google Scholar] [CrossRef]
  166. Agarwal, A.; Salahuddin, A.; Wang, H.; Ahamed, M.J. Design and development of an efficient fluid mixing for 3D printed lab-on-a-chip. Microsyst. Technol. 2020, 26, 2465–2477. [Google Scholar] [CrossRef]
  167. Su, R.; Wang, F.; McAlpine, M.C. 3D printed microfluidics: Advances in strategies, integration, and applications. Lab Chip 2023, 23, 1279–1299. [Google Scholar] [CrossRef] [PubMed]
  168. Formlabs. Guide to Microfluidics and Millifluidics, and Lab-on-a-Chip Manufacturing. 2023. Available online: https://formlabs.com/blog/microfluidics-millifluidics-lab-on-a-chip-manufacturing/ (accessed on 23 August 2023).
  169. Formlabs. Desktop Millifluidics with SLA 3D Printing; Technical report; Formlabs: Somerville, MA, USA, 2020. [Google Scholar]
  170. Johnson, B.N.; Lancaster, K.Z.; Hogue, I.B.; Meng, F.; Kong, Y.L.; Enquist, L.W.; McAlpine, M.C. 3D printed nervous system on a chip. Lab Chip 2016, 16, 1393–1400. [Google Scholar] [CrossRef] [PubMed]
  171. Srikanth, S.; Jayapiriya, U.; Dubey, S.K.; Javed, A.; Goel, S. A lab-on-chip platform for simultaneous culture and electrochemical detection of bacteria. Iscience 2022, 25, 105388. [Google Scholar] [CrossRef] [PubMed]
  172. Michl, J.; Park, K.C.; Swietach, P. Evidence-based guidelines for controlling pH in mammalian live-cell culture systems. Commun. Biol. 2019, 2, 144. [Google Scholar] [CrossRef]
  173. Blain Christen, J.; Andreou, A.G. Design, Fabrication, and Testing of a Hybrid CMOS/PDMS Microsystem for Cell Culture and Incubation. IEEE Trans. Biomed. Circuits Syst. 2007, 1, 3–18. [Google Scholar] [CrossRef]
  174. Song, Q.; Sun, J.; Mu, Y.; Xu, Y.; Zhu, Q.; Jin, Q. A new method for polydimethylsiloxane (PDMS) microfluidic chips to maintain vacuum-driven power using Parylene C. Sens. Actuators B Chem. 2018, 256, 1122–1130. [Google Scholar] [CrossRef]
  175. Ren, K.; Zheng, Y.; Dai, W.; Ryan, D.; Fung, C.; Wu, H. Soft-lithography-based high temperature molding method to fabricate whole Teflon microfluidic chips. In Proceedings of the 14th International Conference on Miniaturized Systems for Chemistry and Life Sciences, Groningen, The Netherlands, 3–7 October 2010; pp. 554–556. [Google Scholar]
  176. Ince, C.; Ypey, D.L.; Diesselhoff-Den Dulk, M.M.; Visser, J.A.; De Vos, A.; Van Furth, R. Micro-CO2-incubator for use on a microscope. J. Immunol. Methods 1983, 60, 269–275. [Google Scholar] [CrossRef]
  177. Golozar, M.; Chu, W.K.; Casto, L.D.; McCauley, J.; Butterworth, A.L.; Mathies, R.A. Fabrication of high-quality glass microfluidic devices for bioanalytical and space flight applications. MethodsX 2020, 7, 101043. [Google Scholar] [CrossRef]
  178. Schmidt, S.; Horch, K.; Normann, R. Biocompatibility of silicon-based electrode arrays implanted in feline cortical tissue. J. Biomed. Mater. Res. 1993, 27, 1393–1399. Available online: https://onlinelibrary.wiley.com/doi/pdf/10.1002/jbm.820271106 (accessed on 8 January 2023). [CrossRef] [PubMed]
  179. Carpignano, F.; Silva, G.; Surdo, S.; Leva, V.; Montecucco, A.; Aredia, F.; Scovassi, A.I.; Merlo, S.; Barillaro, G.; Mazzini, G. A New Cell-Selective Three-Dimensional Microincubator Based on Silicon Photonic Crystals. PLoS ONE 2012, 7, e48556. [Google Scholar] [CrossRef]
  180. Matellan, C.; Armando, E. Cost-effective rapid prototyping and assembly of poly (methyl methacrylate) microfluidic devices. Sci. Rep. 2018, 8, 6971. [Google Scholar] [CrossRef] [PubMed]
  181. Mathur, A.; Roy, S.; Tweedie, M.; Mukhopadhyay, S.; Mitra, S.; McLaughlin, J. Characterisation of PMMA microfluidic channels and devices fabricated by hot embossing and sealed by direct bonding. Curr. Appl. Phys. 2009, 9, 1199–1202. [Google Scholar] [CrossRef]
  182. Shamsi, A.; Amiri, A.; Heydari, P.; Hajghasem, H.; Mohtashamifar, M.; Esfandiari, M. Low cost method for hot embossing of microstructures on PMMA by SU-8 masters. Microsyst. Technol. 2014, 20, 1925–1931. [Google Scholar] [CrossRef]
  183. Picard, C.; Hearnden, V.; Massignani, M.; Achouri, S.; Battaglia, G.; MacNeil, S.; Donald, A. A micro-incubator for cell and tissue imaging. BioTechniques 2010, 48, 135–138. [Google Scholar] [CrossRef] [PubMed]
  184. Choi, Y.H.; Son, S.U.; Lee, S.S. Micro Cell Incubator with On-Chip Integrated Carbon Dioxide Generator as a Self pH Controller. Key Eng. Mater. 2006, 326, 879–882. [Google Scholar] [CrossRef]
  185. Takano, A.; Tanaka, M.; Futai, N. On-chip CO2 incubation for pocket-sized microfluidic cell culture. Microfluid. Nanofluidics 2012, 12, 907–915. [Google Scholar] [CrossRef]
  186. Moldovan, C.; Iosub, R.; Codreanu, C.; Firtat, B.; Necula, D.; Brasoveanu, C.; Stan, I. Miniaturized Integrated Platform for Electrical and Optical Monitoring of Cell Cultures. Sensors 2012, 12, 11372–11390. [Google Scholar] [CrossRef]
  187. Rodrigue, H.; Bhandari, B.; Wang, W.; Ahn, S.H. 3D soft lithography: A fabrication process for thermocurable polymers. J. Mater. Process. Technol. 2015, 217, 302–309. [Google Scholar] [CrossRef]
  188. Marasso, S.; Puliafito, A.; Mombello, D.; Benetto, S.; Primo, L.; Bussolino, F.; Pirri, C.; Cocuzza, M. Optimized design and fabrication of a microfluidic platform to study single cells and multicellular aggregates in 3D. Microfluid. Nanofluidics 2017, 21, 29. [Google Scholar] [CrossRef]
  189. Fujii, T. PDMS-based microfluidic devices for biomedical applications. Microelectron. Eng. 2002, 61–62, 907–914. [Google Scholar] [CrossRef]
  190. Lamberti, A.; Marasso, S.L.; Cocuzza, M. PDMS membranes with tunable gas permeability for microfluidic applications. RSC Adv. 2014, 4, 61415–61419. [Google Scholar] [CrossRef]
  191. Anderson, J.R.; Chiu, D.T.; Jackman, R.J.; Cherniavskaya, O.; McDonald, J.C.; Wu, H.; Whitesides, S.H.; Whitesides, G.M. Fabrication of Topologically Complex Three-Dimensional Microfluidic Systems in PDMS by Rapid Prototyping. Anal. Chem. 2000, 72, 3158–3164. [Google Scholar] [CrossRef]
  192. Datta-Chaudhuri, T.; Abshire, P.; Smela, E. Packaging commercial CMOS chips for lab on a chip integration. Lab Chip 2014, 14, 1753–1766. [Google Scholar] [CrossRef]
  193. Miled, A.; Landari, H. Live Cell Imaging Chamber and Measurement Thereof. U.S. Patent US20210292702A1, 23 September 2021. [Google Scholar]
Table 1. Neurotransmitter sensing methods: a comparison for a new area of miniaturized sensors.
Table 1. Neurotransmitter sensing methods: a comparison for a new area of miniaturized sensors.
TechniqueEase of UseLocationPotential for Miniaturization in the Short TermReference
MRI, MRS, PET, SPECTLowin vivo ≥ in vitroLow [12,13,14,15,16,17,18,19,20,21,22]
CV, FSCV, AmperometryHighin vitro + in vivoHigh[3,23,24,25,26,27,28,29,30,31,32,33,34,35,36,37,38]
MicrodialysisHigh *in vivo ≥ in vitroHigh *[11,39,40,41,42,43,44,46,47]
FluorescenceMediumin vitroMedium[48,49,50,51,52,53,54,55,56,57]
ChemiluminescenceMediumin vitroMedium[58,59,60,61,62,63,64]
Optical Fiber biosensorsMediumin vitro + in vivoHigh[66,67,68,69,70]
LSPRHighin vitroMedium[68,106,107,108,109,110,111,112,113]
SERSLowin vivo ≤ in vitroMedium[30,69,71,72,73,74,75,76,77,78,79,80,81,82,83,84,85,86,87,88,89,90,91,92,93,94,95,96,97,98,99,100,101,102,103,104,105]
* With the usage of a secondary analysis method. Miniaturization of PET and SPECT instrument were demonstrated previously but are not common [114,115,116].
Table 2. Report of different microfabricated LoC or OoC types of devices for biochemical studies. The application of each device, the sensing technique employed, and the measurement resolution are presented.
Table 2. Report of different microfabricated LoC or OoC types of devices for biochemical studies. The application of each device, the sensing technique employed, and the measurement resolution are presented.
AuthorsApplicationSensing MethodDetectionReference
Ndyabawe et al.Brain-on-a-chipFluorescenceImaging[146]
Uzel et al.Controlled concentration gradient in cell matrixFluorescenceImaging[147]
Park et al.AD pathogenesisFluorescenceImaging[148,154]
Yong et al.Axon degenerationFluorescenceImaging[149]
Bologini et al.PD-specific neuronsFluorescenceImaging[150]
Liu et al.Epilepsy-on-a-chipVoltammetryElectrical recordings[151]
Shin et al.Blood-Brain BarrierFluorescenceImaging[152]
Majumdar et al.Neural co-cultureFluorescenceImaging[155]
Li et al.Synaptic releaseAmperometry1 μ M NE[156]
Kundu et al.3D Printed, 3D Microelectrode ArraysVoltammetryElectrical recordings[157]
Hyung et al.Peripheral nervous system–on–a–chipFluorescenceImaging[158]
Yu et al.Dopamine uptakeVoltammetry30 nM DA[159]
Senel et al.Dopamine detectionAmperometry0.1 nM DA[160]
Taylor et al.Neuronal culture deviceFluorescenceImaging[161]
Croushore et al.neuropeptide signalingExternal MSS/N ≥ 5[162]
Sharma et al.3D functional human peripheral nerveVoltammetryElectrical recordings[163]
Johnson et al.3D printed neurons-on-a-chipFluorescenceImaging[170]
Table 3. Summary of different manufacturing technology employed for micro-incubator fabrication.
Table 3. Summary of different manufacturing technology employed for micro-incubator fabrication.
TechniqueApplicationAdvantagesDisadvantagesReference
Hybrid CMOS/PDMS MicrosystemA low-cost centimeter-scale disposable microdevice for cell culture and incubationLess costly than CMOS alternative, biocompatible, ease of useSingle-use-only, fabrication of the mold and every unit is difficult[173]
3D soft lithographyFabrication of complex 3D PDMS partsAllows fabrication of complex PDMS structures, biocompatibleComplex fabrication process, Single-use-only, not scalable[187]
Positive CMOS mold fabrication for PDMS moldingFabrication of a microfluidic platform to study single cells and multicellular aggregates in 3DWell-established micromachining techniques, simple molding process, biocompatibleSystem needs to be sealed using glass plates, single-use, moderately scalable[174,188,189]
Table 4. Incubator technology and size comparison.
Table 4. Incubator technology and size comparison.
TechnologyDimensionsApplicationAdvantagesDisadvantagesReference
Conventional micro-CO 2 -incubator for use on a microscopeCompactCulture observation, Numeric vision analysisGlass top for visibility, good temperature and pressure controlHigh cost, harder pH control[176]
New compact micro-CO 2 -incubator for use with an imaging deviceCompactMulti-culture control and monitoringGlass top and bottom for visibility, good temperature, and pressure control, low-cost fabrication, multisampleHigh complexity[193]
Microfabrication of a micro-incubator for cell and tissue imagingCompactObserve cell monolayers and tissue samples in a changing controlled environment ± 0.05 °C temperature control, heating or cooling, 2D or 3D samplesMedium composition change, membrane change every 10 experiments[183]
Micro Cell Incubator with On-Chip Integrated CO 2 Generator as a Self pH ControllerOn-ChipCellular culture in remote areas, low maintenance applications, preservation of cellular cultures for transportInternal CO 2 production, up to 9 cell chambersLesser pH control than incubators with CO 2 tanks[184]
On-chip CO 2 incubation for pocket-sized microfluidic cell cultureOn-ChipAllows shipment of cellular cultures from remote areasOn-chip CO 2 production, very low maintenance, maintain cultures unattended for up to 17 daysNo pH feedback control, power consumption issues for portability[185]
Miniaturized Integrated Platform for Electrical and Optical Monitoring of Cell CulturesOn-ChipReal-time sampling, Pharmaceutical research, and drug monitoring for personalized treatmentAllows precise observation of cellular growth, modular platform for computer analysisRequires proper control and understanding of the platform[186]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Lachance, G.P.; Gauvreau, D.; Boisselier, É.; Boukadoum, M.; Miled, A. Breaking Barriers: Exploring Neurotransmitters through In Vivo vs. In Vitro Rivalry. Sensors 2024, 24, 647. https://doi.org/10.3390/s24020647

AMA Style

Lachance GP, Gauvreau D, Boisselier É, Boukadoum M, Miled A. Breaking Barriers: Exploring Neurotransmitters through In Vivo vs. In Vitro Rivalry. Sensors. 2024; 24(2):647. https://doi.org/10.3390/s24020647

Chicago/Turabian Style

Lachance, Gabriel Philippe, Dominic Gauvreau, Élodie Boisselier, Mounir Boukadoum, and Amine Miled. 2024. "Breaking Barriers: Exploring Neurotransmitters through In Vivo vs. In Vitro Rivalry" Sensors 24, no. 2: 647. https://doi.org/10.3390/s24020647

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop