Next Article in Journal
Vanadium-Oxide-Based Thin Films with Ultra-High Thermo-Optic Coefficients at 1550 nm and 2000 nm Wavelengths
Next Article in Special Issue
A Two-Year Evaluation of Corrosion-Induced Damage to Hot Galvanized Reinforcing Steel B500SP in Chloride Contaminated Concrete
Previous Article in Journal
Biphenyl Wrinkled Mesoporous Silica Nanoparticles for pH-Responsive Doxorubicin Drug Delivery
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Chloride Diffusion in Concrete Protected with a Silane-Based Corrosion Inhibitor

1
Department of Engineering and Applied Sciences, University of Bergamo, 24044 Dalmine (BG), Italy
2
UdR Materials and Corrosion, Consorzio INSTM, 50121 Florence, Italy
3
UdR Bergamo, Consorzio CSGI, 50019 Sesto Fiorentino, Italy
*
Author to whom correspondence should be addressed.
Materials 2020, 13(8), 2001; https://doi.org/10.3390/ma13082001
Submission received: 25 March 2020 / Revised: 23 April 2020 / Accepted: 23 April 2020 / Published: 24 April 2020
(This article belongs to the Special Issue Corrosion in Concrete: Inhibitors and Coatings)

Abstract

:
One of the most important parameters concerning durability is undoubtedly represented by cement matrix resistance to chloride diffusion in environments where reinforced concrete structures are exposed to the corrosion risk induced by marine environment or de-icing salts. This paper deals with protection from chloride ingress by a silane-based surface-applied corrosion inhibitor. Results indicated that the corrosion inhibitor (CI) allows to reduce the penetration of chloride significantly compared to untreated specimens, independently of w/c, cement type, and dosage. Reduction of chloride diffusion coefficient (Dnssn) measured by an accelerated test in treated concrete was in the range 30–60%. Natural chloride diffusion test values indicate a sharp decrease in apparent diffusion coefficient (Dapp) equal to about 75% when concrete is protected by CI. Mechanism of action of CI in slowing down the chloride penetration inside the cement matrix is basically due to the water repellent effect as confirmed by data of concrete bulk electrical resistivity.

1. Introduction

Concrete alkalinity promotes the formation of a passive protective oxide layer able to prevent corrosion of steel rebars and guarantees an adequate service life of reinforced concrete structures [1]. However, de-passivation of reinforcements can take place for many reasons, among which the most widespread is when chlorides reach a critical concentration at the interface cement matrix/steel bar. Chlorides can penetrate inside the cement matrix from external sources by capillary suction or by diffusion, for example, from contact or proximity to sea water or in a structure where de-icing salts are used, but can also be added incorrectly into the concrete through contaminated aggregates, admixtures, or water [2,3]. It is well known that the chloride-induced corrosion is one of the most dangerous and common phenomena for reinforced concrete structures in the marine environment or exposed to de-icing salts [4]. In a perspective of sustainability in the construction sector and to prevent premature structural failures due to chloride-induced corrosion, it is important to investigate possible strategies to counteract this degradation phenomenon [5,6]. Before dealing with these preventive methods, it is important to underline how the correct choice of concrete cover and mixture composition plays an important role in hindering the diffusion process of chlorides inside the cement matrix [7,8]. In agreement with the diagram of Tuuti [9], one of the main goals consists in slowing down the chloride diffusion inside the matrix in order to delay the onset of the corrosion process. Several alternative strategies have been proposed for increasing the durability of reinforced concrete structures exposed to chloride-rich environments such as coatings [10,11], cathodic protection [12,13], chloride extraction [14], and use of corrosion inhibitors [15,16,17,18,19]. Among these, the use of corrosion inhibitors (CI) is one of the most effective and cheaper ways to prevent the chloride-induced corrosion of reinforced concrete structures.
Two different types of corrosion inhibitors are available on the market: the admixed inhibitors, added to fresh concrete, and migrating corrosion inhibitors—also called penetrating inhibitors or surface-applied corrosion inhibitors—applied on the hardened concrete surface [20]. In particular, the latter seems to be an interesting solution for existing concrete structures exposed to chlorides such as infrastructures, bridges, marine structures, seawater pipelines, and chemical industries [21]. Many investigations have been conducted on surface-applied corrosion inhibitors. Soylev et al. evidenced the effectiveness of amino alcohol-based surface-applied corrosion inhibitors due to a pore-blocking effect as demonstrated by the resistivity measurements of concrete [22]. However, the inhibitors seem to block the pores on the surface of concrete rather than the bulk concrete similarly to a waterproofing treatment [23]. Holloway et al. found that the corrosion inhibitor was still present in the concrete cover at 5 years from application [24]. Research by Fedrizzi et al. demonstrated that the simultaneous use of the alkanolamine-based inhibitor with a good barrier coating offers protection against chloride-induced rebar corrosion [25]. Finally, the efficiency of a surface-applied corrosion inhibitor based on alkylaminoalcohol was highlighted by Morris and Vazquez, especially when it was applied on low-quality concretes manufactured with raw materials contaminated with chloride ions [26].
The purpose of this paper is to evaluate the performances of a silane-based corrosion inhibitor applied on the surface of concrete element in order to slow down chloride diffusion in cement matrix and, consequently, to delay the onset of the corrosion process. The experimental program was carried out both in the form of accelerated and natural diffusion tests in different concrete mixtures manufactured in order to evaluate—other than the efficiency of CI treatment—the influence of w/c, cement type, and cement factor on the penetration mechanism. For each concrete, the chloride diffusion coefficient (Dnssm also called DRCM) was calculated to quantify the reduction in the penetration of chloride into the cement matrix in accordance with Spiesz and Brouwers [27] and Li et al. [28].

2. Materials and Methods

Seven different types of concrete have been manufactured (Table 1). Water/cement ratio and cement factor were selected in order to meet requirements for the exposure classes XD and XS according to EN 206 [29]. The denomination of the different concretes was made taking into consideration the different variables analysed: type of cement (natural pozzolanic cement: CEM IV/A-P 42.5R, limestone Portland cement: CEM II/A-L 42.5R, and blast furnace cement: CEM III/A 42.5R—Table 2), w/c ratio (0.55, 0.50, and 0.45) and cement factor (320, 340, and 360 kg/m3). Finally, natural siliceous sand and gravel (three different gradings) with a maximum size equal to 22 mm were combined in order to meet the Bolomey curve (Figure 1).
At the end of the mixing procedure, workability was measured by flow table according to EN 12350-5 [30]. In addition, specific mass and entrapped air were evaluated on fresh concretes according to EN 12350-6 [31] and EN 12350-7 [32] standards, respectively. For each concrete mixture, 30 cubic specimens (150 × 150 mm) and 32 cylindric specimens (d = 100 mm and h = 200 mm) were manufactured. Concrete samples were removed from the steel molds after 24 h and subsequently cured according to the scheme in Table 3. Compressive strength on hardened concrete was also determined at different ages (EN 12390-3 [33]).
For the estimation of chloride penetration into concrete, accelerated migration tests, natural diffusion tests, and bulk electrical resistivity measurements were carried out on concrete with and without silane-based surface treatment as detailed in the following paragraphs. In particular, after a proper curing time (Table 3), half of the specimens were subjected to a silane-based surface-applied corrosion inhibitor while the others were used as an untreated reference. The properties of the corrosion inhibitor and application procedure are reported in Table 4.

2.1. Accelerated Chloride Migration Tests

Accelerated chloride migration tests were carried out according to NT BUILD 492 [34]. A cylindrical water-saturated concrete specimen (100 mm diameter and 50 mm height) was placed between two cells, one of them filled with 0.30 N NaOH solution and the other with a 10 wt.% NaCl solution. A 30 V DC potential was applied across the sample and the initial current was evaluated. Based on the measured initial current, the test voltage and the test duration were selected according to the NT BUILD 492. A data logger (Germann Instruments Ltd., Copenhaghen, Denmark) was used to record the electrical current, the temperature, and the electrical permeability during the test. Finally, the penetration depth of chlorides was determined by means of a 0.1 M silver nitrate solution [35,36] and the chloride diffusion coefficient (Dnssm) was calculated by the following equation [27]:
D nssm = RT zFE   ×   x d     α x d t
with
E = U     2 L ,
α = 2 RT zFE erf 1 ( 1     2 c d c 0 )
where z is the absolute value of ion valence, F is the Faraday constant, U is the absolute value of the applied voltage, R is the gas constant, T is the average value of the initial and final temperatures in the anolyte solution, L is the thickness of the specimen, Xd is the average value of the penetration depths, t is the test duration, erf−1 is the inverse of error function, Cd is the chloride concentration at which the color changes, and C0 is the chloride concentration in the catholyte solution.

2.2. Natural Chloride Diffusion Tests

For the natural chloride diffusion test, 150 mm cubic specimens were stored in a 3 wt.% NaCl solution at 20 °C for six months. The solution was replaced monthly and, at fixed intervals (1–2–3–6 months), the samples were split into two halves by means of a compression testing machine (Controls Spa, Liscate (MI), Italy) and the penetration of chlorides was measured using the previously described colorimetric method based on silver nitrate [35,36].

2.3. Bulk Electrical Resistivity Tests

The standard method reported in ASTM C1760 was used to evaluate the bulk electrical resistivity of concrete with and without corrosion inhibitor. The water-saturated concrete sample (100 mm diameter and 100 mm height) was positioned between the test cells used for accelerated chloride migration test containing 3 wt.% NaCl solution and an electrical potential of 60 V DC was applied across the specimen. The bulk electrical resistivity was calculated using the following equation:
ρ = V I × π d 2 4 L
where ρ is the electrical resistivity in kΩ·cm, V is the applied voltage (60 V), I is the current in A, d is the specimen diameter (100 mm), and L is the specimen length (100 mm).

3. Results and Discussion

3.1. Fresh Properties

In Table 5, the fresh properties of concretes are listed. No substantial differences between the different mixtures in terms of workability, air content, and specific mass at fresh state were noticed. All concretes evidenced workability class F4 according to EN 206 [29] and the air content reflects the one expected for concrete manufactured with aggregate having maximum size equal to 22 mm. Finally, the specific mass at fresh state is similar for all concretes investigated.

3.2. Elasto-Mechanical Properties

Table 6 shows results of compressive strength at different ages; as expected, the lower the w/c, the higher the compressive strength values.
Compressive strength at 210 days is 26–30% higher than the corresponding value achieved at 28 days for concretes manufactured with pozzolanic (IV) and blastfurnace (III) cements. The 210-day strength value of limestone Portland cement concrete (II), on the contrary, is only 18% higher than the 28-day compressive strength. Data confirm that when a pozzolanic or blastfurnace cement is used, a higher increase of compressive strength with time is achieved as a consequence of the pozzolanic reaction [37].

3.3. Bulk Electrical Resistivity Tests Results

The average bulk electrical resistivity of water-saturated concretes is reported in Table 7. As shown, all values related to untreated concretes are in the range of 5–8 kΩ·cm after 7 days and 8–14 kΩ·cm after 28 days, in accordance with Layssi et al. [38] and Neville [37]. Small differences are detected by varying the cement factor at equal w/c; on the contrary, the electrical resistivity increase when low w/c was adopted and it decreases when limestone Portland cement (II) was used instead of pozzolanic cement (IV) or blastfurnace (III) cement due to the denser structure promoted by the pozzolanic reaction of slag and natural pozzolan [39]. The use of a surface-applied corrosion inhibitor on concrete determines a strong increase in electrical resistivity, both at 7 and 28 days. However, the increasing in electrical resistivity is higher at 7 days (about +85%–+145%) respect to that at 28 days (about +40%–+65%).
Figure 2 shows the bulk electrical resistivity of both treated and untreated specimens as a function of compressive strength of concrete. Figure 3 clearly confirms a significant increase in the electrical resistivity as a consequence of the surface treatment by CI and it seems to indicate that the surface-applied corrosion inhibitors acts as a water repellent protection.
Data highlight the positive role of w/c since the electrical resistivity increases with concrete compressive strength independently of whether the specimen is treated or not, confirming results available in literature [40,41,42]. Moreover, the slope of the trend line for treated specimens is higher than that of untreated concrete. Assuming the strong direct relationship between the electrical resistivity and chloride diffusion reported in several papers [43,44,45], data reported in Figure 3 indicate that the corrosion inhibitor is more effective in slowing down chloride diffusion in concretes having high mechanical performances.

3.4. Accelerated Chloride Migration Tests Results

The chloride diffusion coefficient (Dnssn) resulting from the accelerated diffusion test basically depends on the depth of chloride penetration in concrete (Table 8). As expected, the concretes manufactured with pozzolanic cement (IV) or blastfurnace cement (III) show a lower chloride diffusion coefficient with respect to limestone Portland cement-based mixtures (II). In particular, the Dnssm is in the range of 14–22 × 10−12 m2/s at 7 days and 6–16 × 10−12 m2/s at 28 days for III and IV samples, while II specimens reach values close to 28 × 10−12 m2/s and 21 × 10−12 m2/s, respectively. Protecting the concrete surface by the CI treatment determines a significant reduction of chloride penetration, independently of the age of concrete (7 or 28 days) when the accelerated diffusion test is carried out. The reduction of Dnssm is close to 30–40% if measured on samples water cured for 7 days and it slightly decreases at 21–39% when concrete is cured 28 days.
Figure 3 reports the chloride diffusion coefficient (Dnssn) of pozzolanic cement-based concretes (IV) as a function of w/c ratio. Data are in good agreement with electrical resistivity results confirming the effectiveness of CI treatment in preventing chloride ingress inside the matrix. Moreover, according to electrical resistivity data, the efficiency of the CI treatment seems to be higher than the lower the w/c.
Figure 4 presents the chloride diffusion coefficient (Dnssn) vs. cement factor for concrete manufactured with CEM IV/A-P 42.5 R at the same w/c (0.50). Results confirm the positive role of the CI treatment, independently of the cement dosage. Similar to the bulk electrical resistivity, the chloride diffusion coefficient is not strongly influenced by the cement factor. Experimental results are in agreement with Bertolini et al. [46], affirming the binder content of the cement-based mixtures does not entail significant differences in terms of resistance to the penetration of chlorides.
Figure 5 shows chloride diffusion coefficient (Dnssn) vs. cement type for concrete manufactured with the same w/c (0.50). Data confirm the efficiency of CI treatment independently of the cement type. Results also indicate the positive role of pozzolanic and blastfurnace cement in reducing the chloride penetration inside the matrix as a consequence of the binding capacity of pozzolanic reaction products [47,48,49].
On the basis of the experimental results of the accelerated chloride diffusion test, it is possible to affirm that the surface-applied corrosion inhibitor performs better if applied on concrete intrinsically resistant to chloride penetration manufactured with a pozzolanic or blastfurnace cement and with a low w/c ratio.
Finally, from the analysis of parameters resulting from the accelerated chloride migration tests and the bulk electrical resistivity tests, it was possible, in accordance with Layssi et al. [38], to correlate the chloride diffusion coefficient and the electrical conductivity of concrete (Figure 6). A linear correlation can be found, in accordance with the Nernst–Einstein equation, that can lead to hypothesize that the protective corrosion inhibitor acts only in terms of increasing electrical resistivity (water repellent effect) without chemically modifying the ability to bind chloride ions.

3.5. Natural Migration Test

Figure 7 shows chloride penetration vs. time for concrete specimens immersed in 3 wt.% NaCl aqueous solution. After 6 month of immersion, untreated samples evidenced a chloride penetration in the range of 11–20 mm, while the penetration depth of treated specimens is about 3–8 mm. Results clearly indicate that the CI treatment is strongly efficient in reducing the chloride diffusion independently of the w/c, the type and the dosage of cement, confirming the results registered for the accelerated chloride diffusion test.
After three months of exposure, a reduction of 65–90% could be noticed in chloride penetration as a consequence of the CI treatment (Figure 8). After 6 months, concrete depth penetrated by chloride in treated samples is lower than that measured in untreated specimens of about 55–75%. Data seem to indicate that the efficiency of CI treatment in slowing down chloride diffusion slightly decreases with time. This behavior could be attributable to a partial leaching of the corrosion inhibitor as a consequence of the permanent immersion in chloride-based solution as already hypothesized by Zheng et al. [50]. Further results at ages longer than 6 months are in progress to understand if efficiency of the surface-applied corrosion inhibitor remains constant or decreases with time.
Chloride penetration values (X) measured from the natural diffusion test over six months are used for the calculation of the average value (Table 9) of apparent diffusion coefficient (Dapp) according to the following equation [51]:
0.66 X = 1206 9.46 × 10 7 × T SLS × D app + dx
where 0.66 X coincides with the depth at which the critical concentration of chlorides is reached (0.4% respect to cement mass), TSLS is the duration of the exposure to the chloride-rich solution expressed in years, and dx is the thickness of the convection layer depending on the concrete compressive strength. At equal w/c (0.50), Dapp values are in the range of 0.20–0.30 × 10−12 m2/s for untreated concretes manufactured with blastfurnace (III) or pozzolanic (IV) cements while limestone Portland cement-based mixtures (II) evidenced higher apparent diffusion coefficients, close to 1.15 × 10−12 m2/s. The reduction in w/c promotes the formation of denser cementitious matrix with low Dapp in accordance with the study of Neville [37].
Treatment by the corrosion inhibitor determines a sharp decrease of Dapp; values of treated concrete are in the range of 0.03–0.21 × 10−12 m2/s, about 75% lower than those detected for concretes without treatment. The efficiency of CI treatment seems to be independent of w/c, type, and dosage of cement. However, the lowest values for Dapp were obtained for those concretes intrinsically resistant to chloride penetration (low w/c and pozzolanic or blastfurnace cement), confirming the same results obtained for the accelerated chloride diffusion test.
Figure 9 compares Dapp and 28-day Dnssn; the correspondence between the two coefficients is linear and the proportionality factor is consistent, as reported in study of Spiesz and Brouwers [27]. In particular, the regression line of treated specimens is placed below that of untreated concretes and the slope is lower compared to the same value of untreated samples. These two aspects confirm that the CI protective treatment is particularly effective since the increase of the Dnssm determines a slower growth of Dapp in treated specimens.

4. Conclusions

The following conclusions could be drawn from the present study:
  • The surface-applied corrosion inhibitor allows to reduce significantly the penetration of chloride in concrete, independently of w/c, cement type, and dosage. Reduction of the chloride diffusion coefficient (Dnssn) measured by an accelerated test in treated concrete was in the range 30–60%. Natural chloride diffusion test values indicate a sharp decrease in Dapp equal to about 75% when concrete is protected by the surface-applied CI.
  • Mechanism of action of CI in slowing down the chloride penetration inside the cement matrix is basically due to the water repellent effect as confirmed by data of concrete electrical resistivity and accelerated chloride migration test results.
  • The w/c ratio has confirmed to have a significant influence on chloride diffusion: the lower the w/c, the lower the penetration inside the cement matrix. On the contrary, no significant differences are observed in chloride penetration changing the cement dosage at the same w/c ratio.
  • The type of cement considerably affects the chloride diffusion in concrete; in particular, it has been confirmed that limestone Portland cement (II) should be avoided in environments rich in chlorides, preferring pozzolanic (IV) or blast furnace (III) cements.
Further experimental data are in progress to evaluate the effectiveness of the surface-applied corrosion inhibitor at very long ages. Moreover, further studies should be focused on understanding if the migrating corrosion inhibitor is capable to stop corrosion in chloride contaminated concrete where the critical chloride concentration is reached on the steel rebars.

Author Contributions

Conceptualization, L.C., D.C., E.C. and G.G.; methodology, L.C., D.C., E.C. and G.G.; validation, D.C. and E.C.; investigation, G.G.; data curation, D.C.; writing—original draft preparation, G.G.; writing—review and editing, L.C. and D.C.; supervision, L.C. and T.P.; project administration, L.C. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external founding.

Acknowledgments

The authors would like to acknowledge Eng. Oscar Dozio for the development of the elasto-mechanical tests.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Bertolini, L.; Elsener, B.; Pedeferri, P.; Redaelli, E.; Polder, R.B. Corrosion of Steel in Concrete: Prevention, Diagnosis, Repair; Wiley WCH: Weinheim, Germany, 2013. [Google Scholar]
  2. Collepardi, M.; Marcialis, A.; Turriziani, R. Penetration of Chloride Ions into Cement Pastes and Concretes. J. Am. Ceram. Soc. 1972, 55, 534–535. [Google Scholar] [CrossRef]
  3. De Weerdt, K.; Colombo, A.; Coppola, L.; Justnes, H.; Geiker, M.R. Impact of the associated cation on chloride binding of Portland cement paste. Cem. Concr. Res. 2015, 68, 196–202. [Google Scholar] [CrossRef]
  4. Wu, L.; Li, W.; Yu, X. Time-dependent chloride penetration in concrete in marine environments. Constr. Build. Mater. 2017, 152, 406–413. [Google Scholar] [CrossRef]
  5. Coppola, L.; Coffetti, D.; Crotti, E.; Gazzaniga, G.; Pastore, T. An Empathetic Added Sustainability Index (EASI) for cementitious based construction materials. J. Clean. Prod. 2019, 220, 475–482. [Google Scholar] [CrossRef]
  6. Coppola, L.; Coffetti, D.; Crotti, E. An holistic approach to a sustainable future in concrete construction. IOP Conf. Ser. Mater. Sci. Eng. 2018, 442, 012024. [Google Scholar] [CrossRef] [Green Version]
  7. Lollini, F.; Carsana, M.; Gastaldi, M.; Redaelli, E.; Bertolini, L. The challenge of the performance-based approach for the design of reinforced concrete structures in chloride bearing environment. Constr. Build. Mater. 2015, 79, 245–254. [Google Scholar] [CrossRef] [Green Version]
  8. Zhang, H.; Zhang, W.; Gu, X.; Jin, X.; Jin, N. Chloride penetration in concrete under marine atmospheric environment – analysis of the influencing factors. Struct. Infrastruct. Eng. 2016, 12, 1428–1438. [Google Scholar] [CrossRef]
  9. Tuutti, K. Corrosion of Steel in Concrete; Swedish Foundation for Concrete Research: Stockholm, Sweden, 1982. [Google Scholar]
  10. Brenna, A.; Beretta, S.; Berra, M.; Diamanti, M.V.; Ormellese, M.; Pastore, T.; Pedeferri, M.P.; Bolzoni, F. Effect of polymer modified cementitious coatings on chloride-induced corrosion of steel in concrete. Struct. Concr. 2019, 201900255. [Google Scholar] [CrossRef]
  11. Diamanti, M.V.; Brenna, A.; Bolzoni, F.; Berra, M.; Pastore, T.; Ormellese, M. Effect of polymer modified cementitious coatings on water and chloride permeability in concrete. Constr. Build. Mater. 2013, 49, 720–728. [Google Scholar] [CrossRef]
  12. Oleiwi, H.M.; Wang, Y.; Curioni, M.; Chen, X.; Yao, G.; Augusthus-Nelson, L.; Ragazzon-Smith, A.H.; Shabalin, I. An experimental study of cathodic protection for chloride contaminated reinforced concrete. Mater. Struct. Constr. 2018, 51, 1–11. [Google Scholar] [CrossRef] [Green Version]
  13. Wang, F.; Xu, J.; Xu, Y.; Jiang, L.; Ma, G. A comparative investigation on cathodic protections of three sacrificial anodes on chloride-contaminated reinforced concrete. Constr. Build. Mater. 2020, 246, 1–10. [Google Scholar] [CrossRef]
  14. Tissier, Y.; Bouteiller, V.; Marie-Victoire, E.; Joiret, S.; Chaussadent, T.; Tong, Y.Y. Electrochemical chloride extraction to repair combined carbonated and chloride contaminated reinforced concrete. Electrochim. Acta 2019, 317, 486–493. [Google Scholar] [CrossRef]
  15. Ormellese, M.; Berra, M.; Bolzoni, F.; Pastore, T. Corrosion inhibitors for chlorides induced corrosion in reinforced concrete structures. Cem. Concr. Res. 2006, 36, 536–547. [Google Scholar] [CrossRef]
  16. Cabrini, M.; Fontana, F.; Lorenzi, S.; Pastore, T.; Pellegrini, S. Effect of Organic Inhibitors on Chloride Corrosion of Steel Rebars in Alkaline Pore Solution. J. Chem. 2015, 2015, 521507. [Google Scholar] [CrossRef] [Green Version]
  17. Gartner, N.; Kosec, T.; Legat, A. The efficiency of a corrosion inhibitor on steel in a simulated concrete environment. Mater. Chem. Phys. 2016, 184, 31–40. [Google Scholar] [CrossRef]
  18. Pan, C.; Li, X.; Mao, J. The effect of a corrosion inhibitor on the rehabilitation of reinforced concrete containing sea sand and seawater. Materials 2020, 13, 1480. [Google Scholar] [CrossRef] [Green Version]
  19. Ngala, V.T.; Page, C.L.; Page, M.M. Corrosion inhibitor systems for remedial treatment of reinforced concrete. Part 2: Sodium monofluorophosphate. Corros. Sci. 2003, 45, 1523–1537. [Google Scholar] [CrossRef]
  20. Söylev, T.A.; Richardson, M.G. Corrosion inhibitors for steel in concrete: State-of-the-art report. Constr. Build. Mater. 2008, 22, 609–622. [Google Scholar] [CrossRef]
  21. Elsener, B.; Angst, U. 14—Corrosion inhibitors for reinforced concrete. In Science and Technology of Concrete Admixtures; Aïtcin, P.-C., Flatt, R.J., Eds.; Woodhead Publishing: Cambridge, UK, 2016; pp. 321–339. [Google Scholar] [CrossRef]
  22. Söylev, T.A.; McNally, C.; Richardson, M. Effectiveness of amino alcohol-based surface-applied corrosion inhibitors in chloride-contaminated concrete. Cem. Concr. Res. 2007, 37, 972–977. [Google Scholar] [CrossRef]
  23. Söylev, T.A.; McNally, C.; Richardson, M.G. The effect of a new generation surface-applied organic inhibitor on concrete properties. Cem. Concr. Compos. 2007, 29, 357–364. [Google Scholar] [CrossRef]
  24. Holloway, L.; Nairn, K.; Forsyth, M. Concentration monitoring and performance of a migratory corrosion inhibitor in steel-reinforced concrete. Cem. Concr. Res. 2004, 34, 1435–1440. [Google Scholar] [CrossRef]
  25. Fedrizzi, L.; Azzolini, F.; Bonora, P.L. The use of migrating corrosion inhibitors to repair motorways’ concrete structures contaminated by chlorides. Cem. Concr. Res. 2005, 35, 551–561. [Google Scholar] [CrossRef]
  26. Morris, W.; Vázquez, M. A migrating corrosion inhibitor evaluated in concrete containing various contents of admixed chlorides. Cem. Concr. Res. 2002, 32, 259–267. [Google Scholar] [CrossRef]
  27. Spiesz, P.; Brouwers, H.J.H. The apparent and effective chloride migration coefficients obtained in migration tests. Cem. Concr. Res. 2013, 48, 116–127. [Google Scholar] [CrossRef]
  28. Li, L.Y.; Easterbrook, D.; Xia, J.; Jin, W.L. Numerical simulation of chloride penetration in concrete in rapid chloride migration tests. Cem. Concr. Compos. 2015, 63, 113–121. [Google Scholar] [CrossRef]
  29. EN 206-1. Concrete. Specification, Performance, Production and Conformity; BSI Standards Publication: London, UK, 2016. [Google Scholar]
  30. EN 12350-5. Testing Fresh Concrete. Flow Table Test; BSI Standards Publication: London, UK, 2019. [Google Scholar]
  31. EN 12350-6. Testing Fresh Concrete. Density; BSI Standards Publication: London, UK, 2019. [Google Scholar]
  32. EN 12350-7. Testing Fresh Concrete. Air Content. Pressure Methods; BSI Standards Publication: London, UK, 2019. [Google Scholar]
  33. EN 12390-3. Testing Hardened Concrete. Compressive Strength of Test Specimens; BSI Standards Publication: London, UK, 2019. [Google Scholar]
  34. NT BUILD 492. Concrete, Mortar and Cement-based Repair Materials. Chloride Migration Coefficient from Non-stedy-state Migration Experiments; NordTest: Taastrup, Denmark, 1999. [Google Scholar]
  35. Yuan, Q.; Deng, D.; Shi, C.; de Schutter, G. Application of silver nitrate colorimetric method to non-steady-state diffusion test. J. Cent. South Univ. 2012, 19, 2983–2990. [Google Scholar] [CrossRef]
  36. Baroghel-Bouny, V.; Belin, P.; Maultzsch, M.; Henry, D. AgNO3 spray tests: Advantages, weaknesses, and various applications to quantify chloride ingress into concrete. Part 2: Non-steady-state migration tests and chloride diffusion coefficients. Mater. Struct. 2007, 40, 783. [Google Scholar] [CrossRef]
  37. Neville, A. Properties of Concrete; Pearson Education Limited: Harlow, UK, 2011. [Google Scholar]
  38. Layssi, H.; Ghods, P.; Alizadeh, A.; Salehi, M. Electrical Resistivity of Concrete. Concr. Int. 2015, 293–302. [Google Scholar]
  39. Lübeck, A.; Gastaldini, A.L.G.; Barin, D.S.; Siqueira, H.C. Compressive strength and electrical properties of concrete with white Portland cement and blast-furnace slag. Cem. Concr. Compos. 2012, 34, 392–399. [Google Scholar] [CrossRef]
  40. McCarter, W.J.; Starrs, G.; Chrisp, T.M. Electrical conductivity, diffusion, and permeability of Portland cement-based mortars. Cem. Concr. Res. 2000, 30, 1395–1400. [Google Scholar] [CrossRef]
  41. Shi, C. Effect of mixing proportions of concrete on its electrical conductivity and the rapid chloride permeability test (ASTM C1202 or ASSHTO T277) results. Cem. Concr. Res. 2004, 34, 537–545. [Google Scholar] [CrossRef]
  42. Abdelrahman, M.; Xi, Y. The effect of w/c ratio and aggregate volume fraction on chloride penetration in non-saturated concrete. Constr. Build. Mater. 2018, 191, 260–269. [Google Scholar] [CrossRef]
  43. Polder, R.B. Critical chloride content for reinforced concrete and its relationship to concrete resistivity. Mater. Corros. 2009, 60, 623–630. [Google Scholar] [CrossRef]
  44. Ramezanianpour, A.A.; Pilvar, A.; Mahdikhani, M.; Moodi, F. Practical evaluation of relationship between concrete resistivity, water penetration, rapid chloride penetration and compressive strength. Constr. Build. Mater. 2011, 25, 2472–2479. [Google Scholar] [CrossRef]
  45. Gulikers, J. Theoretical considerations on the supposed linear relationship between concrete resistivity and corrosion rate of steel reinforcement. Mater. Corros. 2005, 56, 393–403. [Google Scholar] [CrossRef]
  46. Bertolini, L.; Lollini, F.; Redaelli, E. Comparison of Resistance to Chloride Penetration of Different Types of Concrete through Migration and Ponding Tests. In Modelling of Corroding Concrete Structures; Andrade, C., Mancini, G., Eds.; Springer: Dordrecht, The Netherlands, 2011; pp. 125–135. [Google Scholar]
  47. Argiz, C.; Moragues, A.; Menéndez, E. Use of ground coal bottom ash as cement constituent in concretes exposed to chloride environments. J. Clean. Prod. 2018, 170, 25–33. [Google Scholar] [CrossRef]
  48. Yildirim, H.; Ilica, T.; Sengul, O. Effect of cement type on the resistance of concrete against chloride penetration. Constr. Build. Mater. 2011, 25, 1282–1288. [Google Scholar] [CrossRef]
  49. Dellinghausen, L.M.; Gastaldini, A.L.G.; Vanzin, F.J.; Veiga, K.K. Total shrinkage, oxygen permeability, and chloride ion penetration in concrete made with white Portland cement and blast-furnace slag. Constr. Build. Mater. 2012, 37, 652–659. [Google Scholar] [CrossRef]
  50. Zheng, H.; Li, W.; Ma, F.; Kong, Q. The effect of a surface-applied corrosion inhibitor on the durability of concrete. Constr. Build. Mater. 2012, 37, 36–40. [Google Scholar] [CrossRef]
  51. Petcherdchoo, A. Time dependent models of apparent diffusion coefficient and surface chloride for chloride transport in fly ash concrete. Constr. Build. Mater. 2013, 38, 497–507. [Google Scholar] [CrossRef]
Figure 1. Grading curves of the aggregates (left). Bolomey and combined aggregate curves (right).
Figure 1. Grading curves of the aggregates (left). Bolomey and combined aggregate curves (right).
Materials 13 02001 g001
Figure 2. Correlation between electrical resistivity and compressive strength for treated and untreated concrete.
Figure 2. Correlation between electrical resistivity and compressive strength for treated and untreated concrete.
Materials 13 02001 g002
Figure 3. Chloride diffusion coefficient (Dnssn) vs. w/c ratio at 7 days (left) and 28 days (right).
Figure 3. Chloride diffusion coefficient (Dnssn) vs. w/c ratio at 7 days (left) and 28 days (right).
Materials 13 02001 g003
Figure 4. Chloride diffusion coefficient (Dnssn) vs. cement dosage at 7 days (left) and 28 days (right).
Figure 4. Chloride diffusion coefficient (Dnssn) vs. cement dosage at 7 days (left) and 28 days (right).
Materials 13 02001 g004
Figure 5. Chloride diffusion coefficient (Dnssn) vs. cement type for concrete manufactured with the same w/c (0.50) at 7 days (left) and 28 days (right).
Figure 5. Chloride diffusion coefficient (Dnssn) vs. cement type for concrete manufactured with the same w/c (0.50) at 7 days (left) and 28 days (right).
Materials 13 02001 g005
Figure 6. Correlation between chloride diffusion coefficient and electrical conductivity of concrete.
Figure 6. Correlation between chloride diffusion coefficient and electrical conductivity of concrete.
Materials 13 02001 g006
Figure 7. Correlation between chloride penetration and time (untreated concrete in black, treated concretes in red).
Figure 7. Correlation between chloride penetration and time (untreated concrete in black, treated concretes in red).
Materials 13 02001 g007
Figure 8. Reduction of depth penetration after natural migration test for different concretes.
Figure 8. Reduction of depth penetration after natural migration test for different concretes.
Materials 13 02001 g008
Figure 9. Correlation between Dnssm and Dapp.
Figure 9. Correlation between Dnssm and Dapp.
Materials 13 02001 g009
Table 1. Composition of the concretes.
Table 1. Composition of the concretes.
ConcreteCEM IV/A-P 42.5 R [kg/m3]CEM II/A-LL 42.5 R [kg/m3]CEM III/A 42.5 R [kg/m3]Aggregates [kg/m3]Water [kg/m3]w/c
IV-0.55-320320 18801760.55
IV-0.50-340340 18751700.50
II-0.50-340 340 18851700.50
III-0.50-340 34018751700.50
IV-0.50-320320 19151600.50
IV-0.50-360360 18301800.50
IV-0.45-360360 18851620.45
Table 2. Main properties of cements.
Table 2. Main properties of cements.
PropertiesCEM IV/A-P 42.5 RCEM II/A-LL 42.5 RCEM III/A 42.5 R
Specific mass [kg/dm3]3.013.103.05
Specific surface [m2/kg]480400400
Setting time [min]>130>130>60
Table 3. Specimens, curing procedure, and preparation.
Table 3. Specimens, curing procedure, and preparation.
TestCuring and PreparationSpecimen FormatNote
Compressive strengthCuring at 20 °C and R.H. > 95% until the deadlineCube
150 mm
1–7–28–70–100–130–210 days; 2 samples for each age
Accelerated chloride diffusion test
-
Bulk electrical resistivity test
Curing at 20 °C and R.H. > 95% for 7 days; Preparation of specimens by sawing and grinding; Drying in oven at 60 °C; Application of the CI; Water saturation for 24 h of samples for 7-day tests; Soaking the specimen in water for 28-day testsCylinder
d: 100 mm
h: 50 mm
-
d: 100 mm
h: 100 mm
7–28 days;
8 samples for each age (4 treated and 4 untreated)
Natural chloride diffusion testCuring at 20 °C and R.H. > 95% for 14 days; Curing at 20 °C and R.H. 60% for 28 days; Application of the CI; Immersion of specimens in a 3 wt.% NaCl solution until the deadlineCube
150 mm
1–2–3–6 months of immersion;
4 samples for each age (2 treated and 2 untreated)
Table 4. Properties of the corrosion inhibitor and application procedure.
Table 4. Properties of the corrosion inhibitor and application procedure.
PropertiesValue
ColorStraw yellow
Viscosity [mPa·s]0.95 ± 0.05
Dry residue [%]7 ± 0.3
pH6.5 ± 0.2
Density [kg/dm3]0.88 ± 0.05
Average consumption [L/m2]0.25 for each coat
Number of coats4
Time between coats15 min
Application methodBrush
Table 5. Properties of concretes at fresh state.
Table 5. Properties of concretes at fresh state.
ConcreteWorkability [mm]Air Content [%]Specific Mass [kg/m3]
IV-0.55-3205501.62375
IV-0.50-3405201.72380
II-0.50-3405301.82395
III-0.50-3405401.92385
IV-0.50-3205301.92395
IV-0.50-3605301.82375
IV-0.45-3605101.62405
Table 6. Cubic compressive strength (fc) results.
Table 6. Cubic compressive strength (fc) results.
Concretew/c RatioCubic Compressive Strength: fc [MPa]
1 d7 d28 d70 d100 d130 d210 d210 d-fc/28 d-fc
IV-0.55-3200.5511.123.132.036.639.439.941.2129%
IV-0.50-3400.5013.528.435.840.842.543.546.4130%
II-0.50-3400.5016.728.836.839.841.443.143.4118%
III-0.50-3400.5013.525.332.338.140.941.942.9133%
IV-0.50-3200.5013.829.035.839.743.043.345.0126%
IV-0.50-3600.5017.531.336.840.543.745.046.9127%
IV-0.45-3600.4517.832.841.845.848.850.053.1127%
Table 7. Bulk electrical resistivity tests results.
Table 7. Bulk electrical resistivity tests results.
ConcreteBulk Electrical Resistivity at 7 d [kΩ·cm]Bulk Electrical Resistivity at 28 d [kΩ·cm]
UntreatedTreatedUntreatedTreated
IV-0.55-3205.611.39.215.0
IV-0.50-3406.915.410.516.6
II-0.50-3405.09.57.712.0
III-0.50-3407.613.313.819.8
IV-0.50-3206.215.212.818.6
IV-0.50-3607.217.212.918.3
IV-0.45-3607.917.112.018.5
Table 8. Values of chloride diffusion coefficient of concretes.
Table 8. Values of chloride diffusion coefficient of concretes.
ConcreteDnssm [×10−12 m2/s]
Untreated SpecimensTreated SpecimensReduction [%]
7 d28 d7 d28 d7 d28 d
IV-0.55-32022.516.116.412.927.121.3
IV-0.50-34021.913.712.98.941.135.1
II-0.50-34028.120.819.514.030.832.7
III-0.50-34014.07.69.65.731.425.0
IV-0.50-32021.613.113.29.838.925.2
IV-0.50-36018.712.612.79.232.127.0
IV-0.45-36017.06.710.14.040.639.4
Table 9. Average values of Dapp for different concretes.
Table 9. Average values of Dapp for different concretes.
ConcreteDapp [×10−12 m2/s]Reduction [%]
Untreated SpecimensTreated Specimens
IV-0.55-3200.940.2177.6
IV-0.50-3400.190.0478.9
II-0.50-3401.150.2677.4
III-0.50-3400.320.0778.1
IV-0.50-3200.270.0677.8
IV-0.50-3600.240.0675.0
IV-0.45-3600.130.0376.9

Share and Cite

MDPI and ACS Style

Coppola, L.; Coffetti, D.; Crotti, E.; Gazzaniga, G.; Pastore, T. Chloride Diffusion in Concrete Protected with a Silane-Based Corrosion Inhibitor. Materials 2020, 13, 2001. https://doi.org/10.3390/ma13082001

AMA Style

Coppola L, Coffetti D, Crotti E, Gazzaniga G, Pastore T. Chloride Diffusion in Concrete Protected with a Silane-Based Corrosion Inhibitor. Materials. 2020; 13(8):2001. https://doi.org/10.3390/ma13082001

Chicago/Turabian Style

Coppola, Luigi, Denny Coffetti, Elena Crotti, Gabriele Gazzaniga, and Tommaso Pastore. 2020. "Chloride Diffusion in Concrete Protected with a Silane-Based Corrosion Inhibitor" Materials 13, no. 8: 2001. https://doi.org/10.3390/ma13082001

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop