Next Article in Journal
Comprehensive Model for Real Battery Simulation Responsive to Variable Load
Previous Article in Journal
Future of Sustainable Management of Energy Companies in Terms of Attitudes and Preferences of the Younger Generation
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Reply

Reply to Sinha, P.; Wade, A. Comment on “Nover et al. Leaching via Weak Spots in Photovoltaic Modules. Energies 2021, 14, 692”

1
Institute for Photovoltaics and Research Center SCoPE, University of Stuttgart, 70569 Stuttgart, Germany
2
Institute for Sanitary Engineering, Water Quality, and Solid Waste Management, University of Stuttgart, 70569 Stuttgart, Germany
*
Author to whom correspondence should be addressed.
Energies 2021, 14(11), 3208; https://doi.org/10.3390/en14113208
Submission received: 12 April 2021 / Accepted: 25 May 2021 / Published: 31 May 2021

1. Introduction

In their comment [1], Sinha and Wade made several remarks on our long-term leaching studies [2] of photovoltaic (PV) modules. Both authors work for the company First Solar, whose main product is CdTe modules. Similar to previous publications [3,4,5], we again found CdTe not to be stable in aqueous solutions, not even in neutral water with pH 7 [2]. Thus, it is not a question anymore if the carcinogenic Cd and Te are leached out from CdTe module pieces but just a question of how long it takes.
Sinha and Wade [1] described well-known standard module testing methods at length. Those methods are type tests, which are applied to a relatively small number of modules for each module type before distribution; they must not be mixed up with routine tests of individual modules of the same type before distribution. In contrast, our data are relevant for distributed, installed, individual, damaged modules in the field, or for those which, after end of use, may end up in landfills.
Indeed, our research and publications [2,3,4,5] have been followed and persecuted [6] by Sinha and Wade during the last few years, similarly to research of others [7,8,9]. We replied on their comments already earlier [10]. Here, Sinha and Wade essentially use the following arguments, to seed doubts against our leaching studies [1]:
(i)
Our leaching experiments, which varied pH, time, temperature, and encapsulation would be “artificial and do not occur in nature”.
(ii)
Using buffered solutions (to keep the pH constant over the time of the experiments) for leaching experiments would not represent “actual field conditions”.
(iii)
Acidic solutions with pH3 would neither be representative for leaching in rainwater nor for landfills.
(iv)
An earlier study of Steinberger [11] using rainwater found leachate concentrations to “meet environmental limits”.
(v)
“With respect to end-of-life landfill disposal, recent research from Nain and Kumar [12] shows that standard short-term waste characterization tests overestimate leaching risks from PV modules, in comparison to observed long-term (60-day) leaching using actual landfill leachate.”

2. Our Replies

2.1. Variation of pH, Time, Temperature, Agitation

Indeed, our conditions are artificial; in nature, they are probably even worse. For example, in a landfill, module pieces might be subjected (even simultaneously) to inorganic and organic liquids, microbes (bacteria, archaea, fungi), insects, electrocorrosion due to illumination, and so on. To keep conditions well-defined and simple, we restricted our studies to time-dependent leaching in water-based solutions with pH 3, pH 7, and pH 11 in the dark [2]. Indeed, our carefully designed experiments showed the leaching to depend not only on pH but also on temperature and agitation, and in case of CdTe modules [2] also on the size and shape of CdTe particles [5]. The wide range of pH values allows one now to predict the behavior of module pieces subjected to water-based solutions with other pH-values, see also Ref. [10].

2.2. Constant pH by Buffering

Identification of leaching mechanisms, time dependences, and measuring the leaching speeds over a long period in time t (up to t ≈ 1.5 years) requires keeping the pH constant (as well as temperature, lack of illumination, possible agitation, etc.), despite leaching out not only the toxic substances but also dissolving the module glass. This glass dissolution leads to a slow increase of the pH if the volume of the solution is constant. For example, such an increase is shown in Figure 1 of Ref. [1]. The speed of the pH increase depends on the ratio of the volume of module pieces to the volume of the leaching solvent. Unfortunately, Sinha and Wade [1] did not give information about this ratio. In addition, the contact of the solutions to ambient air (also not mentioned by Sinha and Wade [1]) could also increase the pH of the solutions. Thus, a pH increase with time is possible even without module pieces if the volume of the solution is limited. This matter could be clarified by a proper reference experiment! To come up with conclusive leaching data for module pieces in a water-based leaching solution of well-defined pH, we decided to use buffered solutions with a limited volume of about 1 liter. The bottles were closed and lightproof. The buffering itself only keeps the pH constant over time; it does not change the leaching, but buffering allows one to find the pH dependence of the leaching speed, i.e., the dependence of the leached amount for each element on time t! Alternatively, to keep the pH constant over time t via buffering, we could have used (and wasted) huge amounts of solutions in huge tanks and added the small module pieces. With the known leaching speeds for different pH values, we are now able to model leaching also for a time-dependent pH (t). Nevertheless, even in nature, the pH of the “solution” might also be constant in time, simply because, for example, rainwater flows over the module pieces, leaches out the toxic substances, and then drains away. With the next rain, new rainwater with similar pH may fall, leach again, drain away, and so on. Therefore, the leaching will also never stop.

2.3. Rainwater and pH 3; pH and Landfills

We used experiments with pH 3 (apart from pH 7, pH 11) to have data also on the lower scale of pH values. This wide range of pH allows us also to conclude on the action of rainwater, whatever the pH may be. In Ref. [5] we stated that in Brazil, the pH of rainwater ranges at 4.2 < pH < 6.1, rainwater in Germany ranges at 4.1 < pH < 5.3, mineralized water ranges at 4.9 < pH < 8.4, and sea water is in the narrow range 7.5 < pH < 8.5. In Figure 1 of their own comment [1], Sinha and Wade hold up against us a pH ≈ 5.4 as a median value of average pH of rainfall for measurement stations in Germany and USA. However, as their value is a median (and not an average value), it means that 50% of the data point collected by them showed a lower pH value. Here, not a median, but a mean value would be more informative. In addition, we do not understand why they mixed values of Germany and the USA. Anyway, their own claimed pH data for rainwater fit well into the data quoted by us.
Concerning landfills: We stated earlier in Ref. [5], landfills in Germany to range at 3.4 < pH < 11.9 [Ref. [24] in [5]]. Here, we give again some more detailed, newer data for Germany: The updated Ref. [13] lists measured data for landfills: 3.8 < pH < 13.1 for inorganic waste (page 25 in Ref. [13]), 7.2 < pH < 8.3 for municipal waste (page 12 in Ref. [13]), 2.3 < pH < 13.9 for waste from the building/construction sector (page 30 in Ref. [13]), and 3.3 < pH < 12 for hazardous waste (page 6 in Ref. [13]). For the United Kingdom, we found, for example, 6.2 < pH < 8 [14], and for Malaysia, 4.5 < pH < 9 [15]. Thus, our investigations with pH 3, pH 7, and pH 11 cover the pH range of landfills quite well.

2.4. Rainwater Studies of Steinberger

The modules we tested stem from present-day mass production. For the CdTe modules, we observed substantial Cd leaching even for pH 7: After 1.5 years, about 4.5% of the Cd was leached out from the module pieces, even in a limited solution of 1 liter which went into saturation; see Figure 12d of Ref. [2]. The cells’ Mo back contact is the weak spot [2]. For the quoted pH 5.4 for rainwater of Figure 1 from Sinha and Wade [1], one might expect around 50% of Cd to be leached out during the same time—simply due to the higher Cd solubility limit for the lower pH. In contrast, Steinberger’s publication from 1998 [11] reported low Cd leaching for his experiments with rainwater; the source of the CdTe modules was not revealed. Only one module stemmed from commercial production—we guess from the early CdTe production of the German company Antec Solar. Unfortunately, the type, the quality, and the deposition method of the back contact, as well as the quality of sealing of these modules is not known to us. Such differences may or may not be the reason for the possibly different leaching behavior—if it exists at all! The experimental conditions of Steinberger’s early, rather short publication [11] were only poorly described, as already stated by us in our reply [10] to Ref. [6]. Only the size of the module pieces (10 mm) was mentioned in Ref. [11]. Nothing was stated about their shape, their sealing, the pH, the redox potential, the temperature, and the total amount of water in which the module pieces were immersed. Did he measure the leached-out amount per week, or the total amount? In addition, what analysis method for the Cd was used and after which time? Did he measure the Cd in the solution or the Cd in precipitates? For low pH, we did not find precipitation: all Cd was in the solution [2]. We also cannot exclude an influence of illumination in his [11] experiments. Thus, only a proper repetition of Steinberger’s experiments [11] under well-defined conditions with well-defined samples might be convincing.

2.5. Leaching Studies of Nain and Kumar

The statement of Nain and Kumar [12] as quoted above, in our opinion, means that standard short-term waste characterization tests (for example over 6 or 24 h) are inappropriate to judge the long-term leaching risks from PV modules under field conditions or if they stay forever in landfills. We would agree with this interpretation. Nain and Kumar [12] did not study any CdTe modules. Therefore, no direct conclusions on CdTe modules can be drawn from their interesting experiments. However, they studied Cd containing CIGS modules and wrote in their abstract: “The leached metal concentrations were found to be within the threshold limits except for cadmium, copper, lead and selenium …”. In addition, “CIGS was found to be most hazardous with a Metal Hazard Score (calculated on the basis of magnitude of leached metals with respect to their threshold limit and subsequent health effects) of 23.19, when exposed to standard tests.” Would the hazard not even be higher for CdTe? In case of CIGS cells, the thickness of the CdS buffer layer is only around 40 nm. In case of CdTe/CdS cells, the thickness of the layers is around 4 µm. Thus, CdTe modules contain about a factor of 100 more carcinogenic Cd than CIGS-modules. The conclusion of Ref. [12] states pH 7.5 to pH 7.8 for the leaching solutions used. Unfortunately, no value for the redox potentials was given. Clearly, in case of these almost neutral pH values, the leaching is slow. In addition, clearly over 60 days, the amount of leached out elements is low. After this time (and pH 7) and for a solution with limited volume of 1 liter, we found only about 2% of the module’s Cd in the solution; see Figure 12d of Ref. [2]. In this respect, the study of Nain and Kumar [12] nicely fits into our data [2] and vice versa. However, in a landfill, the volume of the liquid in most cases will not be finite! Always, new rainwater will come! Then, the solubility limit in the water will not be reached. A saturation behavior as observed by us, see Figure 12a–f in Ref. [2], most probably will not occur, but the leaching will continue. Nain and Kumar stopped their experiments after 60 days. In contrast, photovoltaic module (pieces) in landfills will stay there forever. For low pH, they will be leached out fast; for high pH, the leaching is slow. Thus, in one case, it may take weeks, while in other cases, it may take decades. In any case, toxic, hazardous, and carcinogenic substances will be leached out. Only omission of them avoids this process.

Conflicts of Interest

The authors declare no conflict of interest. The funders had no role in the design of the study; in the collection, analyses, or interpretation of data; in the writing of the manuscript, or in the decision to publish the results.

References

  1. Sinha, P.; Wade, A. Comment on Nover et al. Leaching via Weak Spots in Photovoltaic Modules. Energies 2021, 14, 692. Energies 2021, 14, 3150. [Google Scholar] [CrossRef]
  2. Nover, J.; Zapf-Gottwick, R.; Feifel, C.; Koch, M.; Werner, J.H. Leaching via Weak Spots in Photovoltaic Modules. Energies 2021, 14, 692. [Google Scholar] [CrossRef]
  3. Nover, J.; Zapf-Gottwick, R.; Feifel, C.; Koch, M.; Metzger, J.; Werner, J.H. Long-term Leaching of Photovoltaic Modules. Jpn. J. Appl. Phys. 2017, 56, 08MD02. [Google Scholar] [CrossRef]
  4. Zapf-Gottwick, R.; Koch, M.; Fischer, K.; Schwerdt, F.; Hamann, L.; Kranert, M.; Metzger, J.; Werner, J.H. Leaching Hazardous Substances out of Photovoltaic Modules. Int. J. Adv. Appl. Phys. Res. 2015, 2, 7. [Google Scholar] [CrossRef]
  5. Zapf-Gottwick, R.; Zorn, M.; Nover, J.; Koch, M.; Feifel, C.; Werner, J.H. Size- and Surface Dependent Solubility of Cadmium Telluride in Aqueous Solutions. Energies 2021, 14, 398. [Google Scholar] [CrossRef]
  6. Sinha, P.; Wade, A. Comment on “Long-term Leaching of Photovoltaic Modules”. Jpn. J. Appl. Phys. 2018, 57, 019101. [Google Scholar] [CrossRef]
  7. Zeng, C.; Ramos-Ruiz, A.; Field, J.A.; Sierra-Alvarez, R. Cadmium Telluride (CdTe) and Cadmium Selenide (CdSe) Leaching Behavior and Surface Chemistry in Response to pH and O2. J. Environ. Manag. 2015, 154, 78. [Google Scholar] [CrossRef] [PubMed]
  8. Sinha, P. Cadmium Telluride Leaching behavior: Discussion of Zeng et al. (2015). J. Environ. Manag. 2015, 163, 184. [Google Scholar] [CrossRef] [PubMed]
  9. Zeng, C.; Ramos-Ruiz, A.; Field, J.A.; Sierra-Alvarez, R. Response to the Comments on “Cadmium Telluride Leaching Behavior: Discussion of Zeng et al. (2015)”. J. Environ. Manag. 2015, 164, 65. [Google Scholar] [CrossRef] [PubMed]
  10. Nover, J.; Zapf-Gottwick, R.; Feifel, C.; Koch, M.; Metzger, J.; Werner, J.H. Reply to “Comment on ‘Long-term Leaching of Photovoltaic Modules‘”. Jpn. J. Appl. Phys. 2018, 57, 019102. [Google Scholar] [CrossRef] [Green Version]
  11. Steinberger, H. Health, Safety and Environmental Risks from the Operation of CdTe and CIS Thin-Film Modules. Prog. Photovolt. Res. Appl. 1998, 6, 99–103. [Google Scholar] [CrossRef]
  12. Nain, P.; Kumar, A. Understanding Metal Dissolution from Solar Photovoltaics in MSW Leachate under Standard Waste Char-acterization Conditions for Informing End-of-life Photovoltaic Waste Management. Waste Manag. 2021, 123, 97–110. [Google Scholar] [CrossRef] [PubMed]
  13. Landesamt für Natur, Umwelt und Verbraucherschutz Nordrhein-Westfalen (Lanuv). Fachbericht 24, Beschaffenheit von Deponiesickerwässer 2018. Available online: https://www.lanuv.nrw.de/fileadmin/lanuvpubl/3_fachberichte/30024.pdf (accessed on 11 March 2021).
  14. Available online: https://leachate.co.uk/main/leachate-chemistry-testing/landfill-leachate-composition/ (accessed on 11 March 2021).
  15. Umar, M.; Hamidi, A.A.; Yusoff, M.S. Variability of Parameters in Leachate Pollution Index and Determination of LPI from Four Landfills in Malysia. Int. J. Chem. Eng. 2010, 2010, 747953. [Google Scholar] [CrossRef]
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Werner, J.H.; Zapf-Gottwick, R.; Nover, J.; Koch, M. Reply to Sinha, P.; Wade, A. Comment on “Nover et al. Leaching via Weak Spots in Photovoltaic Modules. Energies 2021, 14, 692”. Energies 2021, 14, 3208. https://doi.org/10.3390/en14113208

AMA Style

Werner JH, Zapf-Gottwick R, Nover J, Koch M. Reply to Sinha, P.; Wade, A. Comment on “Nover et al. Leaching via Weak Spots in Photovoltaic Modules. Energies 2021, 14, 692”. Energies. 2021; 14(11):3208. https://doi.org/10.3390/en14113208

Chicago/Turabian Style

Werner, Juergen Heinz, Renate Zapf-Gottwick, Jessica Nover, and Michael Koch. 2021. "Reply to Sinha, P.; Wade, A. Comment on “Nover et al. Leaching via Weak Spots in Photovoltaic Modules. Energies 2021, 14, 692”" Energies 14, no. 11: 3208. https://doi.org/10.3390/en14113208

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop