木造接合部におけるほぞ差込み栓の強度特性とその破壊性状に関する実験研究(構造)
渋谷 泉松留 慎一郎前川 秀幸藤田 香織
著者情報
ジャーナル フリー

2003 年 9 巻 18 号 p. 97-100

詳細
抄録

This paper focuses on the joints of failure mode in traditional timber structures. These joints have strong influence on the strength and performance of timber buildings. The purpose of this paper is clarify the strength and failure mode of pegged, mortise and tenon joint. Static shear loading test of the joint was operated. The combination of bending, shear and compressive failure of the peg within the joint was observed through the experiment. The deformation of all the members of each phase is documented in detail. The failure model of the joint was found to be similar to that of the bolt joint for double shear connections.