2003 年 9 巻 17 号 p. 31-36
This study aims to develop a simple and easy joint method of PCa-CFT. First, thermal transition of steel tube and concrete in full-scale models, which are column joint part and column-beam joint part of PCa-CFT, is measured after field welding under nearly actual construction condition. Secondly, thermal analysis method is verified in comparison with the result in full-scale model of column joint part.