skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Beam loss due to the aperture limitation resulting from intrabeam scattering

Technical Report ·
DOI:https://doi.org/10.2172/6219992· OSTI ID:6219992

Diffusion equation is used to evaluate the beam loss in the presence of aperture limitation resulting from the intrabeam scattering. We discuss the effect of different boundary conditions. Satisfactory beam intensity can be maintained within the proposed RHIC operation time.

Research Organization:
Brookhaven National Lab. (BNL), Upton, NY (United States)
DOE Contract Number:
AC02-76CH00016
OSTI ID:
6219992
Report Number(s):
BNL-35438; ON: DE85005138
Resource Relation:
Other Information: RHIC Technical Note No. 5
Country of Publication:
United States
Language:
English