Title: High performance CLSM field mixing and pumping test results

Technical Report ·
DOI:https://doi.org/10.2172/568985· OSTI ID:568985
 [1];  [2]
  1. Bechtel Savannah River, Inc., Aiken, SC (United States)
  2. Westinghouse Savannah River Co., Aiken, SC (United States). Savannah River Technology Center

An improved low bleed water CLSM mix was field tested on May 13, 1997 at the Throop portable auger batching plant. Production and pumping tests were very successful. The four cubic yards of material pumped into a ply wood form where it flowed 48 feet (the entire length of the form). The CLSM slurry was very uniform, self leveling, cohesive, showed no segregation, and had no bleed water. Properties of the High Performance CLSM were the same for material collected at the auger and at the end of the pipeline except for the air content which was 5.5% at the auger and 3.2% at the end of the pipeline. This is exactly what was expected and indicates that this CLSM is easy to mix and pump in the Throop/BSRI equipment. CLSM Mix TW-10 is recommended for Tank Closure based on the field batching and pumping tests.

Research Organization:
Savannah River Site (SRS), Aiken, SC (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC09-96SR18500
OSTI ID:
568985
Report Number(s):
WSRC-RP-97-272; ON: DE97053993; TRN: 98:008648
Resource Relation:
Other Information: PBD: 14 May 1997
Country of Publication:
United States
Language:
English