This document contains a complete set of valid and final digital and analog data plots for LLTR Series II, Test A-2. Included is an Accuracy Statement regarding this data as required by Revision 0 of the GE Test Request, Specification No. 23A2062. The Series II, Sodium-Water Reaction Test A-2 was performed in the Large Leak Test Rig (LLTR) at the Energy Technology Engineering Center (ETEC). This was the third of three planned double-edged guillotine (DEG) rupture tests of a single tube which will be followed by a number of small leak tests. The test article is the LLTI which is a full-size diameter internals, shortened in length and prototypic of the CRBR steam generator. It is installed in the Large Leak Test Vessel (LLTV). The overall test program was formulated by General Electric (GE) as Test Requester to establish steam generator design and to verify analytical models/codes to estimate the effect of large leak accidents in an LMFBR demonstration plant steam generator and system.

Research Organization:
Rockwell International Corp., Canoga Park, CA (United States). Energy Systems Group
DOE Contract Number:
AT03-76SF70030
OSTI ID:
5561830
Report Number(s):
DOE/SF/70030-T48; ON: DE82010136; TRN: 82-010583
Country of Publication:
United States
Language:
English