SODIUM PUMP DEVELOPMENT AND PUMP TEST FACILITY DESIGN
The study defines a program for the development of large sodium pamps for use with sodium cooled reactor systems of 1000 to 1500 Mw(e) capability, and the functionai requirements of a related sodium pump test facility for testing large pumps. The future pump requirements of large power systems have been estimated, a type of sodium pump recommended for farther development, the development problems identified and a program research and developmert prepared to resolve these problems. The functional requirements of a sodium pump test facility for testing pumps for large reactor use have been established. (auth)
- Research Organization:
- Westinghouse Electric Corp. Atomic Power Div., Pittsburgh
- DOE Contract Number:
- AT(30-1)-3123
- NSA Number:
- NSA-18-009581
- OSTI ID:
- 4101282
- Report Number(s):
- WCAP-2347
- Resource Relation:
- Other Information: Orig. Receipt Date: 31-DEC-64
- Country of Publication:
- United States
- Language:
- English
Similar Records
CONCEPTUAL DESIGN AND COST ESTIMATE FOR SODIUM PUMP TEST FACILITY
SURVEY OF SODIUM PUMP TECHNOLOGY
Fast Flux Test Facility replacement of a primary sodium pump
Technical Report
·
Fri Nov 01 00:00:00 EST 1963
·
OSTI ID:4101282
SURVEY OF SODIUM PUMP TECHNOLOGY
Technical Report
·
Sat Jun 01 00:00:00 EDT 1963
·
OSTI ID:4101282
Fast Flux Test Facility replacement of a primary sodium pump
Conference
·
Fri Nov 15 00:00:00 EST 1985
·
OSTI ID:4101282