Clinical utility of ultrasound guidance for intra-articular knee injections: a review

Authors Berkoff, Miller L, Block J 

Received 16 December 2011

Accepted for publication 31 January 2012

Published 20 March 2012 Volume 2012:7 Pages 89—95

DOI https://doi.org/10.2147/CIA.S29265

Review by Single anonymous peer review

Peer reviewer comments 3



David J Berkoff1, Larry E Miller2,3, Jon E Block3
1Department of Orthopedics, University of North Carolina School of Medicine, Chapel Hill, NC; 2Miller Scientific Consulting Inc, Arden, NC; 3The Jon Block Group, San Francisco, CA, USA

Abstract: Intra-articular corticosteroid and hyaluronic acid injections provide short-term symptom amelioration for arthritic conditions involving structural damage or degenerative changes in the knee. Conventional palpation-guided anatomical injections frequently result in inaccurate needle placement into extra-articular tissue and adjacent structures. The purpose of this review was to determine the effect of ultrasound guidance on the accuracy of needle placement, clinical outcomes, and cost-effectiveness in comparison with anatomical landmark-guided intra-articular large joint injections, with particular emphasis on the knee. A total of 13 relevant studies were identified; five studied the knee, seven studied the shoulder, one used both the knee and shoulder, and none studied the hip. Ultrasound was used in seven studies; the remaining studies utilized air arthrography, fluoroscopy, magnetic resonance arthrography, or magnetic resonance imaging. Across all studies (using all imaging modalities and all joints), needle placement accuracy ranged from 63% to 100% with ultrasound and from 39% to 100% with conventional anatomical guidance. Imaging guidance improved the accuracy of intra-articular injections of the knee (96.7% versus 81.0%, P < 0.001) and shoulder (97.3% versus 65.4%, P < 0.001). In particular, ultrasound guidance of knee injections resulted in better accuracy than anatomical guidance (95.8% versus 77.8%, P < 0.001), yielding an odds ratio of 6.4 (95% confidence interval 2.9–14). Ultrasound guidance notably improves injection accuracy in the target intra-articular joint space of large joints including the knee. The enhanced injection accuracy achieved with ultrasound needle guidance directly improves patient-reported clinical outcomes and cost-effectiveness.

Keywords: injection, intra-articular, knee, ultrasound

Creative Commons License © 2012 The Author(s). This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution - Non Commercial (unported, v3.0) License. By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms.