Skip to main content
Log in

Improvement of Analytical Sensitivity by Ar-N2 Inductively Coupled Plasma in Axially Viewing Optical Emission Spectrometry

  • Rapid Communications
  • Published:
Analytical Sciences Aims and scope Submit manuscript

Abstract

The analytical sensitivities of elements were improved by Ar-N2 inductively coupled plasma (Ar-N2 ICP) in axially viewing optical emission spectrometry (OES). A commercially available ICP-OES instrument was used, and only N2 gas was added at flow rates of up to 1.0 L min−1 into Ar plasma gas. A stable Ar-N2 ICP was obtained, and the net signal intensities of elements were enhanced by factors of up to 25 compared to those observed for Ar ICP-OES. The detection limits evaluated were also improved by factors from 5 to 10, especially for elements with relatively higher ionization energies. Moreover, the analytical sensitivities for these elements observed in axially viewing Ar-N2 ICP-OES were superior to those in radially viewing Ar-N2 ICP-OES reported previously. The Ar-N2 ICP is expected to be a useful alternative source for excitation and ionization in axially viewing ICP-OES.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Inductively Coupled Plasmas in Analytical Atomic Spectrometry”, ed. A. Montaser and D. W. Golightly, 1992, VCH, Inc., New York.

  2. Inductively Coupled Plasma Mass Spectrometry”, ed. A. Montaser, 1998, Wiley-VCH, Inc., New York.

  3. ICP Mass Spectrometry Handbook”, ed. S. M. Nelms, 2005, Blackwell Publishing Ltd., Oxford.

  4. A. Montaser and J. Mortazavi, Anal. Chem., 1980, 52, 255.

    Article  CAS  Google Scholar 

  5. A. Montaser, V. A. Fassel, and J. Zalewski, Appl. Spectrosc., 1981, 35, 292.

    Article  CAS  Google Scholar 

  6. A. Montaser and R. L. Van Hoven, CRC Crit. Rev. Anal. Chem., 1987, 18, 45.

    Article  CAS  Google Scholar 

  7. J. Dennaud, A. Howes, E. Poussel, and J. M. Mermet, Spectrochim. Acta, Part B, 2001, 56, 101.

    Article  Google Scholar 

  8. M. Stepan, P. Musil, E. Poussel, and J. M. Mermet, Spectrochim. Acta, Part B, 2001, 56, 443.

    Article  Google Scholar 

  9. E. H. Choot and G. Horlick, Spectrochim. Acta, Part B, 1986, 41, 907.

    Article  Google Scholar 

  10. E. H. Choot and G. Horlick, Spectrochim. Acta, Part B, 1986, 41, 925.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Masaki Ohata.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Ohata, M., Takaku, Y., Inagaki, K. et al. Improvement of Analytical Sensitivity by Ar-N2 Inductively Coupled Plasma in Axially Viewing Optical Emission Spectrometry. ANAL. SCI. 25, 161–163 (2009). https://doi.org/10.2116/analsci.25.161

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.2116/analsci.25.161

Navigation