Abstract
Based on a flow-injection spectrophotometry, an automatic analytical method for determination of ppb-level chloride-ion has been established. By use of this method, a novel FIA method for the determination of SBAER performance has also been developed. In this paper, the effects of concentration, dosage, and flow rate of the regenerant on BEC of SBAER were first investigated dynamically by the FIA method. In addition, the flow rate of the sample water and the temperature of the ion exchange resin were also examined. The optimum conditions were obtained: the volume of the regenerant (sodium hydroxide) was 50 mL (0.15 g resin), and its concentration was 3% (w/v); the volumetric flow rates of the regenerant and the sample water were 0.5 ml/min (4.3 m/h) and 1.5 ml/min (13 m/h), respectively. The exchanging temperature was 25 ± 5°C. The method is characterized by the use of a micro resin-column, shorter testing cycle, easy operation, and high reproducibility. The proposed method is approximately 30 times more efficient than the manual method, and it can be used for the exchange performance comparison of various SBAER.
Similar content being viewed by others
References
F. R. Jiang, Liaoning Chemical Industry, 1997, 26, 239.
Q. Zuo, S. F. Ran, J. Tang, and C. Y. Zhu, Ion Exchange and Adsorption, 1995, 11, 314.
B. S. Wang, Y. M. Liu, Y. G. Zhang, W. L. Li, and B. L. He, Ion Exchange and Adsorption, 1995, 11, 407.
ASTM D 3087-91, “Standard test method for operating performance of anion-exchange materials for strong acid removal”, 1998.
GB 5760-86, “Determination for exchange capacity of anion exchange resins”, 1986.
GB 8144-1987, “Determination for exchange capacity of cation exchange resins”, 1987.
GB 11992-1989, “Strong basic anion exchange resins in chloride form—Determination of exchange capacity”, 1989.
Y.-S. Li and W.-C. Cheng, “Flow Injection Analysis (Chinese)”, 1987, Beijing University Publishing House, No. 13209-47.
Y.-S. Li and Y. Narusawa, Bunseki Kagaku, 1992, 41, 463.
Y.-S. Li and Z.-J. Wang, Laboratory Robotics and Automation, 1995, 7, 229.
Y. Utsumi, Nikka, 1952, 73, 835.
X.-J. Shi, “Treatment of water in power plants”, 1993, Water Conservancy and Electric Power Publishing House, 152.
Y.-S. Li and W.-C. Cheng, Fenxi Yiqi, 1986, 3, 46.
J.-X. Yao, X.-W. Xu, and Y.-Y. Li, “Industrial Boiler Water Treatment and Analysis of Water Quality”, 1987, China Labor Publishing House, 188.
Y.-S. Li and Y.-L. Dong, North China Electric Power, 2003, 266, 18.
Z. Liu, “Instrumental Analysis”, 2001, Chemical Industry Publishing House, 228.