Comparison of visual quality after implantation of A1-UV and SN60WF aspheric intraocular lens
Author:
Contact Author:

Chang-Jun Lan. Department of Ophthalmology, Affiliated Hospital of North Sichuan Medical College, Nanchong 637000, Sichuan Province, China. eyelanchangjun@163.com

Affiliation:

Clc Number:

Fund Project:

Supported by Project of Science & Technology Department of Sichuan Province (No.2019YJ0381); Key Project of Sichuan Health and Family Planning Commission (No.18ZD022).

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    AIM: To compare the visual performance of pseudophakic eyes implanted with A1-UV and SN60WF aspheric intraocular lens (IOL), and to investigate the correlations between visual quality parameters and pupil size. METHODS: This prospective comparative study included 105 eyes of 90 patients with age-related cataract who underwent uneventful phacoemulsification. The subjects were divided into two groups according to the implanted IOL type. Three months postoperatively, visual acuity and contrast sensitivity were measured, wave-front aberrations were assessed using a KR-1W aberrometer (Topcon), and objective optical quality parameters were performed using an optical quality analysis system-OQAS II (Visiometrics). Independent sample t-test and Spearman correlation analysis were used for data analysis. RESULTS: There were no significant differences found in visual acuity, contrast sensitivity and visual quality parameters between the two groups (P>0.05). The measured intraocular spherical aberration (SA) in A1-UV IOL eyes of -0.19±0.05 μm was close to the designed SA value of -0.20 μm. The modulation transfer function cutoff, Strehl ratio and OQAS values were negatively correlated with pupil size in both groups (P<0.01). CONCLUSION: The subjective and objective visual quality in pseudophakic eyes with A1-UV and SN60WF IOLs are comparable. For aspheric IOL eyes, visual quality decreases with increasing pupil size.

    Reference
    Related
    Cited by
Get Citation

Xuan Liao, Ji-Yun Li, Qing-Qing Tan, et al. Comparison of visual quality after implantation of A1-UV and SN60WF aspheric intraocular lens. Int J Ophthalmol, 2020,13(11):1727-1732

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:May 11,2020
  • Revised:August 27,2020
  • Adopted:
  • Online: September 17,2020
  • Published: