Pulse Shape Processing to correct Pile up and Dead Time at High Count Rate by using Digital Spectroscopy Analyzer (DSA)

Authors

  • Adil M. Hussein College of Science, University of Sulaimani, Kurdistan Region, Iraq. Author

DOI:

https://doi.org/10.17656/jzs.10168

Keywords:

Gamma pulse shape processing, Dead time and pile up optimization

Abstract

Rise time parameter in digital spectroscopy analyzer (DSA) is used to obtain a new method for pulse shape processing which is used to correct dead time and pile up at high count rate. When the pile up rejecter has been used the dead time did not eliminate so much, but as the new method has been used (rise time parameter) the dead time decreased to its half value. The effect of rise time on the spectrum such as the relationship between the rise time and each of width pulse shape, dead time, gauss ratio, peak to valley ratio and peak to Compton ratio, have been studied.

References

. K. Ban Leson and D. K. McDaniels, Dead Time Correction for pulsed beams, nuclear instrument and methods, 1971, 91, 295. DOI: https://doi.org/10.1016/0029-554X(71)90670-7

J. S. Byrd and M. H. Goosy, A Pulse Height Analyzer with automatic deferential dead time correction, Savanna River laboratory —USA, 1976.

G. C. Meggitt, A dead time correction system standard modules, nuclear instrument and methods, 1977, 146, 583-585. DOI: https://doi.org/10.1016/0029-554X(77)90213-0

Yaron Danon, Bryndol Sones, Robert Block ,Dead time and pileup in pulsed parametric X-ray spectroscopy, Nuclear Instruments and Methods in Physics Research ,2004,524, 287-294. DOI: https://doi.org/10.1016/j.nima.2003.12.034

M. Capogni_, A. Ceccatelli, P. De Felice, A. Fazio , Random-summing correction and pile-up rejection in thesum-peak method , Applied Radiation and Isotopes , 2006 . 64, 1229-1233. DOI: https://doi.org/10.1016/j.apradiso.2006.02.027

V. Zidek and J. Plch, Dead time calibrator, nuclear instrument and methods, 1974, 119, 247. DOI: https://doi.org/10.1016/0029-554X(74)90759-9

Weijun Guoa, Sang Hoon Leeb, Robin P. Gardner, The Monte Carlo approach MCPUT for correcting pile-up distorted pulse- height spectra, Nuclear Instruments and Methods in Physics Research A ,2004, 531, 521-523 DOI: https://doi.org/10.1016/j.nima.2004.05.089

P. W. Nicholson. Nuclear Electronics, John Wiley & Sons, 1974, 150.

Ortec literature. A practical guide to high rate germanium gamma spectroscopy, www.ortec—online .com, 2002, 25.

D. A. Gedcke, Dealing with dead time distortion in a time digitizer ,www.ortec-online.com ,2002, 3.

Brad Wargelin,XRCF Phase 1 Testing, www.harvard.edu, ch5,p3.

DSA-Digital Spectrum Analyzer hardware manual, v..vnv.canberra.com, 2001, 28-34.

Genie 2000 tutorials manual, www.canberra.com, 2004, 2-38.

Waldemar Scharf and Waldemar Lisieski, amplitude distribution spectrometers, Elsevier scientific publishing company, 1980, 163.

D. Belusa, E. Fretwurst, F. Jaber and G. Lindstom, Pulse Shape Analysis in coaxial Ge(Li) detector, nuclear instrument and methods, 1972, 101, 178. DOI: https://doi.org/10.1016/0029-554X(72)90772-0

T. J. Poulus, Timing electronics and fast timing methods with scintillation detectors, IEEE, Transuction nuclear science, 1985, NS-32( 3), p 1243. DOI: https://doi.org/10.1109/TNS.1985.4337024

Published

2007-04-24

How to Cite

Pulse Shape Processing to correct Pile up and Dead Time at High Count Rate by using Digital Spectroscopy Analyzer (DSA). (2007). Journal of Zankoy Sulaimani - Part A, 10(1), 113-123. https://doi.org/10.17656/jzs.10168

Most read articles by the same author(s)

1 2 3 4 5 6 7 8 9 10 > >>