Acessibilidade / Reportar erro

Estimating 131I biokinetics and radiation doses to the red marrow and whole body in thyroid cancer patients: probe detection versus image quantification* * Study conducted at the Instituto do Câncer do Estado de São Paulo Octavio Frias de Oliveira (Icesp) and at Faculdade de Medicina da Universidade de São Paulo (FMUSP), São Paulo, SP, Brazil.

Estimativa da biocinética do 131I e das doses de radiação na medula óssea vermelha e no corpo inteiro em pacientes com câncer de tireoide: comparação entre o método de detecção de sonda e a quantificação de imagens cintilográficas

Abstract

Objective:

To compare the probe detection method with the image quantification method when estimating 131I biokinetics and radiation doses to the red marrow and whole body in the treatment of thyroid cancer patients.

Materials and Methods:

Fourteen patients with metastatic thyroid cancer, without metastatic bone involvement, were submitted to therapy planning in order to tailor the therapeutic amount of 131I to each individual. Whole-body scans and probe measurements were performed at 4, 24, 48, 72, and 96 h after 131I administration in order to estimate the effective half-life (Teff) and residence time of 131I in the body.

Results:

The mean values for Teff and residence time, respectively, were 19 ± 9 h and 28 ± 12 h for probe detection, compared with 20 ± 13 h and 29 ± 18 h for image quantification. The average dose to the red marrow and whole body, respectively, was 0.061 ± 0.041 mGy/MBq and 0.073 ± 0.040 mGy/MBq for probe detection, compared with 0.066 ± 0.055 mGy/MBq and 0.078 ± 0.056 mGy/MBq for image quantification. Statistical analysis proved that there were no significant differences between the two methods for estimating the Teff (p = 0.801), residence time (p = 0.801), dose to the red marrow (p = 0.708), and dose to the whole body (p = 0.811), even when we considered an optimized approach for calculating doses only at 4 h and 96 h after 131I administration (p > 0.914).

Conclusion:

There is full agreement as to the feasibility of using probe detection and image quantification when estimating 131I biokinetics and red-marrow/whole-body doses. However, because the probe detection method is inefficacious in identifying tumor sites and critical organs during radionuclide therapy and therefore liable to skew adjustment of the amount of 131I to be administered to patients under such therapy, it should be used with caution.

Keywords:
Thyroid neoplasms; Iodine radioisotopes/therapeutic use; Radioisotopes/pharmacokinetics; Dosimetry; Radiotherapy

Resumo

Objetivo:

Comparar o desempenho dos métodos de detecção de sonda e quantificação de imagens na estimativa da biocinética do radioisótopo 131I e das doses de radiação na medula óssea vermelha e no corpo inteiro durante a radioiodoterapia em pacientes com câncer de tireoide.

Materiais e Métodos:

Catorze pacientes portadores de câncer metastático de tireoide, sem acometimento ósseo, foram submetidos ao planejamento terapêutico visando estabelecer a melhor atividade de 131I a ser empregada na radioiodoterapia. Imagens cintilográficas e captações de corpo inteiro foram adquiridas 4, 24, 48, 72 e 96 h após a administração de atividades traçadoras de 131I, visando estimar a meia-vida efetiva (T1/2ef) e o tempo de residência do 131I no organismo dos pacientes.

Resultados:

Os valores médios de T1/2ef e tempo de residência foram, respectivamente, 19 ± 9 h e 28 ± 12 h pelo método de detecção de sonda e 20 ± 13 h e 29 ± 18 h pela quantificação de imagens. As doses médias na medula óssea vermelha e no corpo inteiro foram, respectivamente, 0,061 ± 0,041 mGy/MBq e 0,073 ± 0,040 mGy/MBq pelo método de detecção de sonda e 0,066 ± 0,055 mGy/MBq e 0,078 ± 0,056 mGy/MBq pela quantificação de imagens. A análise estatística demonstrou que os dois métodos apresentam desempenho semelhante no tocante à estimativa de T1/2ef (p = 0,801), tempo de residência (p = 0,801) e doses, tanto na medula óssea vermelha (p = 0,708) como no corpo inteiro (p = 0,811), mesmo com métodos otimizados de dosimetria que levam em consideração somente dois pontos de medida (4 h e 96 h) após a administração de 131I (p > 0,914).

Conclusão:

Existe excelente concordância entre o método de detecção de sonda e a quantificação de imagens quanto à estimativa da biocinética do 131I e das doses absorvidas de radiação. Contudo, o método de detecção de sonda deve ser usado com cuidado por ser incapaz de identificar regiões metastáticas e órgãos críticos durante a terapia com radionuclídeos, podendo distorcer ajustes da atividade de 131I a ser administrada durante a radioiodoterapia.

Unitermos:
Neoplasias da tireoide; Radioisótopos do iodo/uso terapêutico; Radioisótopos/farmacocinética; Dosimetria; Radioterapia

INTRODUCTION

The management of patients with differentiated thyroid cancer involves radioiodine therapy to ablate remnants of thyroid tissues after surgical resection of the gland or in the treatment of metastases(11 Luster M, Clarke SE, Dietlein M, et al. Guidelines for radioiodine therapy of differentiated thyroid cancer. Eur J Nucl Med Mol Imaging. 2008;35:1941-59.). A large amount of 131I is generally administered to patients during the treatment of metastatic diseases. Under these circumstances, it would be more appropriate to tailor the amount according to individual needs and to the radiotoxic effect on healthy organs, such as the red marrow, lungs, kidneys, and salivary glands(22 Dorn R, Kopp J, Vogt H, et al. Dosimetry-guided radioactive iodine treatment in patients with metastatic differentiated thyroid cancer: largest safe dose using a risk-adapted approach. J Nucl Med. 2003;44:451-6.,33 Song H, He B, Prideaux A, et al. Lung dosimetry for radioiodine treatment planning in the case of diffuse lung metastases. J Nucl Med. 2006;47:1985-94.).

Several of the dosimetric methods used for adjusting the amount of 131I to be administered in therapy are based on delivering a maximum radiation dose of 2-3 Gy to red-marrow tissues, while abiding by the rules for radioiodine-avid lung metastases(22 Dorn R, Kopp J, Vogt H, et al. Dosimetry-guided radioactive iodine treatment in patients with metastatic differentiated thyroid cancer: largest safe dose using a risk-adapted approach. J Nucl Med. 2003;44:451-6.,44 Sgouros G, Song H, Ladenson PW, et al. Lung toxicity in radioiodine therapy of thyroid carcinoma: development of a dose-rate method and dosimetric implications of the 80-mCi rule. J Nucl Med. 2006;47:1977-84.). When determining the radiation dose per unit of 131I activity (mGy/MBq) to be received by the red marrow and whole body, sequential measurements of the circulating levels of 131I are generally required. Typically, the circulating level of 131I is either estimated through invasive procedures, such as the collection and analysis of blood samples, or inferred from whole-body radiation measurements with a radiation detection probe or by image quantification(55 Lassmann M, Hänscheid H, Chiesa C, et al. EANM Dosimetry Committee series on standard operational procedures for pre-therapeutic dosimetry I: blood and bone marrow dosimetry in differentiated thyroid cancer therapy. Eur J Nucl Med Mol Imaging. 2008;35:1405-12.,66 Hindorf C, Glatting G, Chiesa C, et al. EANM Dosimetry Committee guidelines for bone marrow and whole-body dosimetry. Eur J Nucl Med Mol Imaging. 2010;37:1238-50.).

Considering the radiation detection probe and image quantification methods as two different procedures, to be used as alternatives for determining radiometric data, our aim here was to compare their performance when estimating 131I biokinetics and radiation doses to the whole body and to the red marrow.

MATERIALS AND METHODS

Patient characteristics and radiometric data acquisition

Fourteen patients with metastatic differentiated thyroid cancer were submitted to a dosimetric protocol in order to tailor the amount of 131I to be administered in individual therapy. None of the patients showed evidence of distant metastasis. The study was approved by the local research ethics committee.

Prior to 131I administration, patients underwent 4-6 weeks of thyroid hormone withdrawal and were maintained on an iodine-poor diet, in order to raise the endogenous thyroid-stimulating hormone level (to > 30 mIU/L) and stimulate 131I uptake by thyroid tissue remnants and metastases. In the present study, exogenous recombinant human thyroid-stimulating hormone was not administered.

The proportional whole-body 131I retention was calculated at 4, 24, 48, 72, and 96 h after 131I administration with a radiation detection probe and a gamma camera. Patient data and measurement times were documented.

Radiation detection probe measurements

An NaI radiation detector (identiFINDERTM Digital Spectrometer; Thermo Fisher Scientific Inc., Erlangen, Germany), with a 35 mm × 51 mm crystal, was used. The individuals were placed in a standing position 3.0 m from the detector, as illustrated in Figure 1. Each measurement was taken three times, for 3 min each time, in the same location (an area with a low background radiation level) every day. The net radioactivity (counts/min) was determined only for the anterior acquisition. Before each patient measurement, the background radiation was measured (also for 3 min) in the absence of the patient. Although partial shielding of the detector was considered propitious, the shielding between the patient and the NaI crystal was removed in order to reduce background radiation. The solid angle of the detector was sufficient to receive photons from the entire body of the patient. The duration of the measurement was sufficient to providing net counts > 105 at each measuring point, even when the background radiation was subtracted.

Figure 1
Schematic arrangement for measuring radiometric data acquired with the probe detection method.

Image acquisition

A dual-head gamma camera-for single-photon emission computed tomography/computed tomography (SPECT/CT)-with a high-energy collimator was used in order to estimate the 131I activity within the body, by whole-body image quantification and as a function of time. Only planar nuclear medicine images were used for quantification. As depicted in Figure 2, the activity was estimated on the basis of the radiation counts for designated regions of interest (ROIs) around the whole body, minus the background radiation, as follows:

Figure 2
Schematic arrangement for measuring radiometric data acquired with the image quantification method

where WBnet is the net whole-body count, WBpixels is the total number of pixels for the whole-body ROI in question, WBcts/pixel is the average count per pixel for the whole-body ROI in question, and BKGcts/pixel is the average count per pixel of background radiation.

A copy of the ROIs (WB and BKG) from the first images was replaced in later images. The same calculation method was applied to each of the five images acquired from each patient. The SPECT/CT was provided with the software Syngo MI Applications 2009A® (Siemens Medical Solutions USA, Inc.; Malvern, PA, USA). Whole-body planar images were acquired in a 256 × 1024 matrix with a scan speed of 8 cm/min. All acquired images were analyzed using the free software Image J, version 1.45s (Wayne Rasband, National Institutes of Health; Bethesda, MD, USA).

One patient was used as a standard source for evaluating the remaining whole-body activity as a function of time after 131I administration, net whole-body counts being normalized to the first data point (taken as 100%). After 131I administration, the patients were allowed to void only after the first probe measurement and image acquisition. When estimating 131I biokinetics and radiation doses, we considered only the anterior view (for probe measurement and image acquisition), given that our experience has shown that there is little difference between the data estimated with this methodology and those estimated by considering conjugate views (anterior and posterior acquisition). Based on whole-body scanning, the net count rate from anterior acquisition only is, on average, approximately 5% superior to that of conjugate acquisition, indicating that determining only the anterior count rate is a practical and easy method for evaluating radioiodine retention as a function of elapsed time after 131I administration.

Red-marrow and whole-body absorbed dose calculation

For each patient, the cumulative whole-body activity (Ãwb) was calculated by applying the following equation:

where A0 is the amount of radioactivity administered, and Teff is the effective whole-body half-life of 131I.

To describe the radiometric data plotted on the graph "estimated whole-body activity versus time of measurement", the Teff was determined by a simple exponential function adjustment:

where λeff = 0.693 / Teff.

According to the radiometric data acquired by probe detection or image quantification, Ãwb, Teff, and residence time were calculated in duplicate for each patient. The residence time was estimated by dividing the Ãwb by the total amount of 131I administered (A0).

The absorbed dose of radiation per unit of 131I activity (mGy/MBq), estimated for the whole body and the red marrow, was calculated with OLINDA/EXM computer soft-ware(77 Stabin MG, Sparks RB, Crowe E. OLINDA/EXM: the second-generation personal computer software for internal dose assessment in nuclear medicine. J Nucl Med. 2005;46:1023-7.). We estimated the absorbed dose by introducing the 131I residence time into the computer program, choosing a specific adult anthropomorphic phantom (adult male or adult female) 131I radionuclide, and adjusting the parameters of the software according to patient body mass and thyroid tissue mass. The last was estimated by calculating the total 131I uptake by remnant tissue after thyroidectomy and considering 1% of the 131I uptake per gram of tissue. As described in a previous study(88 Willegaignon J, Sapienza MT, Buchpiguel CA. Comparison of different dosimetric methods for red marrow absorbed dose calculation in thyroid cancer therapy. Radiat Prot Dosimetry. 2012;149:138-46.), the red-marrow dose was adjusted according to patient weight.

RESULTS

Of the 14 patients evaluated, two were male and 12 were female. Patient ages ranged from 25 to 63 years. All of the patients had previously undergone total or near-total thyroidectomy. The mean value ± 1 standard deviation for patient weight was 77 ± 19 kg, and the mean height was 1.63 ± 0.06 m. The activity of the tracer 131I ranged from 74 MBq to 126 MBq, with a mean value of 87 ± 14 MBq, administered to patients (orally in liquid form) according to a dosimetric protocol and as an aid in staging the disease. Patient characteristics are presented in Table 1.

Table 1
Patient characteristics and units of 131I activity administered to patients for dosimetric purposes.

Table 2 presents the effective half-life and residence time of 131I for each patient, determined by considering radiometric data acquired by means of probe detection and image quantification. The mean half-life and residence time values were 19 ± 9 h and 28 ± 12 h, respectively, for probe detection, compared with 20 ± 13 h and 29 ± 18 h, respectively, for image quantification. The effective half-life calculated from image quantification was, on average, 9.38% higher than that calculated from probe measurements, the difference ranging from 0.09% to 34.53% among the patients. A similar difference was observed in residence times. As can be seen in Figures 3 and 4, no significant difference was found between the probe detection and image quantification methods in terms of the calculated effective half-lives or residence times (p = 0.801 for both).

Table 2
Estimated effective half-life and residence time of 131I when considering individually based radiometric data acquired with probe detection and planar image quantification.

Figure 3
Correlations between effective half-lives calculated from radiometric data acquired with the probe detection and image quantification methods.

Figure 4
Correlations between residence times calculated from radiometric data acquired with the probe detection and image quantification methods.

Radiation doses to the red marrow and whole body per unit of 131I activity administered are presented in Table 3. Mutual correlations, when estimated by probe detection or image quantification, are shown in Figures 5 and 6. When estimated by probe detection, the mean red-marrow and whole-body doses were 0.061 ± 0.041 mGy/MBq and 0.073 ± 0.040 mGy/MBq, respectively, compared with 0.066 ± 0.055 mGy/MBq and 0.078 ± 0.056 mGy/MBq, respectively, when estimated by image quantification. The mean differences between the probe detection and image quantification methods in terms of the radiation doses calculated was similar to those found for the effective half-lives and residence times. The statistical analysis revealed no significant difference between the two methods, in terms of the estimated radiation doses to the red marrow (p = 0.708) and to the whole body (p = 0.811).

Table 3
Estimation of red-marrow and whole-body radiation doses when considering radiometric data from probe detection and planar image quantification.

Figure 5
Correlations between radiation doses to the red marrow, as calculated from radiometric data acquired with the probe detection and image quantification methods.

Figure 6
Correlations between radiation doses to the whole body, as calculated from radiometric data acquired with the probe detection and image quantification methods.

As can be seen in Figures 7 and 8, there were a good correlation between the estimated doses delivered to the red marrow and whole body for the same patient, as calculated by probe detection (p = 0.376; R2 = 0.988) and image quantification (p = 0.490; R2 = 0.993). Overall (as calculated by both methods), the mean radiation dose per unit of 131I activity administered received by the whole body was approximately 27% higher than that received by the red marrow (range, 0.84-44.0%).

Figure 7
Correlations between radiation doses to the red marrow and radiation doses to the whole body when only radiometric data acquired with probe detection were considered.

Figure 8
Correlations between radiation doses to the red marrow and radiation doses to the whole body when only radiometric data acquired with image quantification were considered.

The radiation doses presented in Table 3 were calculated by considering measurements obtained at five time points (4, 24, 48, 72, and 96 h). However, an optimized approach can be applied, given that similar dose estimation results are obtainable when using only the measurements obtained at the two extremes (4 h and 96 h). Correlations between the optimized and the non-optimized method can be seen in Figures 9, 10, 11 and 12. Statistical analysis with a t-test showed that there was no significant difference between the two methods for estimating doses (p > 0.914).

Figure 9
Correlations between radiation doses to the red marrow calculated by considering measurements obtained at five time points (4, 24, 48, 72, and 96 h) and those calculated by considering measurements obtained at only two (4 h and 96 h), using only radiometric data acquired with the probe detection method.

Figure 10
Correlations between radiation doses to the whole body calculated by considering measurements obtained at five time points (4, 24, 48, 72, and 96 h) and those calculated by considering measurements obtained at only two (4 h and 96 h), using only radiometric data acquired with the probe detection method.

Figure 11
Correlations between radiation doses to the red marrow calculated by considering measurements obtained at five time points (4, 24, 48, 72, and 96 h) and those calculated by considering measurements obtained at only two (4h and 96 h), using only radiometric data acquired with the image quantification method.

Figure 12
Correlations between radiation doses to the whole body calculated by considering measurements obtained at five time points (4, 24, 48, 72, and 96 h) and those calculated by considering measurements obtained at only two (4 h and 96 h), using only radiometric data acquired with the image quantification method.

It is important to note that, when estimating the radiation doses to the red marrow and whole body in this study, we did not take into consideration doses received by the patients less than 4 h after 131I administration. Soon after oral administration, 131I is mainly accumulated in the stomach, and requires a certain time before entering into blood circulation. It is assumed that immediate whole-body 131I dispersion would lead to incorrect radiation dose estimation. However, if one considers immediate 131I dispersion in the first 4 h, the dose to the red marrow or whole body would account for only approximately 10% of the total dose received by the two. However, this assumption was not made in the present study, because the main aim here was to compare the performance of probe detection and image quantification in radiation dose estimation.

DISCUSSION

Since 1962, when Benua et al.(99 Benua RS, Cicale NR, Sonenberg M, et al. The relation of radioiodine dosimetry to results and complications in the treatment of metastatic thyroid cancer. Am J Roentgenol Radium Ther Nucl Med. 1962;87:171-82.) presented a study on radioiodine dosimetry for metastatic thyroid cancer patients, many papers on the same topic have been published(88 Willegaignon J, Sapienza MT, Buchpiguel CA. Comparison of different dosimetric methods for red marrow absorbed dose calculation in thyroid cancer therapy. Radiat Prot Dosimetry. 2012;149:138-46.). However, there is still controversy regarding this point, due to a scarcity of studies comparing dose-response correlations according to the dosimetric method employed. In most dosimetric methods, consideration (for dose calculation) is given only to the use of extensive radiometric data from patients undergoing diagnostic or therapeutic procedures. Nevertheless, these data can be acquired by collecting and measuring radiometric data from body fluids or even inferred from body radiation measurement.

According to the European Association of Nuclear Medicine Dosimetry Committee blood and bone marrow dosimetry guidelines for differentiated thyroid cancer(55 Lassmann M, Hänscheid H, Chiesa C, et al. EANM Dosimetry Committee series on standard operational procedures for pre-therapeutic dosimetry I: blood and bone marrow dosimetry in differentiated thyroid cancer therapy. Eur J Nucl Med Mol Imaging. 2008;35:1405-12.), the probe and image quantification methods are considered as alternative procedures for estimating the amounts of radioactive iodine inside the body and provide similar absorbed-dose results when those data are used for internal dose calculation. However, from our point of view, there have been no studies presenting dosimetric data in a satisfactory way to confirm this assumption. In addition, the limitations of using only radiometric data acquired by probe detection to tailor the 131I amount to be administered to metastatic thyroid cancer patients have not been well addressed. In this context, the present study makes a contribution to internal dosimetry by furnishing comparisons of dosimetric data estimated by probe detection and image quantification.

On the basis of the results of the current study, and by applying the methodology described here, we can state that the probe detection and image quantification methods provided similar results when estimating 131I effective half-life and residence time within the body. Therefore, both methods can be considered valid for determining these parameters. The differences between the two methods when estimating radiation doses per unit of 131I activity administered, either to the red marrow or to the whole body were not statistically significant. The mean radiation dose to per unit of 131I activity administered was considerably higher for the whole-body doses than for the red-marrow doses, and the difference was similar to that reported in other studies(88 Willegaignon J, Sapienza MT, Buchpiguel CA. Comparison of different dosimetric methods for red marrow absorbed dose calculation in thyroid cancer therapy. Radiat Prot Dosimetry. 2012;149:138-46.). It is important to note that, depending on the physical characteristics of each patient (e.g., weight and height), that difference could reach values even higher than the 27% observed in the present study, which is a representative value for a standard patient (70 kg in weight and 1.70 m tall), hence the impropriety of using that value for every patient without some kind of adjustment according to patient biotype, especially in the case of patients presenting bone metastases.

When determining appropriate doses, good correlations were found between the absorbed doses determined at five time points (4, 24, 48, 72, and 96 h) and those determined at only two (4 h and 96 h), when either probe detection or image quantification was used. Reducing the number of data points necessary for estimating radiation doses implies a general reduction in the costs involved in nuclear medicine therapy planning, while working in favor of implementing this procedure in the daily routine of a nuclear medicine department. A similar study of optimizing the amount of radiometric data necessary for dosimetry in Graves' disease therapy was previously conducted by our group using the probe detection method(1010 Willegaignon J, Sapienza MT, Coura Filho GB, et al. Determining thyroid (131)I effective half-life for the treatment planning of Graves' disease. Med Phys. 2013;40:022502.,1111 Willegaignon J, Sapienza MT, Coura-Filho GB, et al. Graves' disease radioiodine-therapy: choosing target absorbed doses for therapy planning. Med Phys. 2014;41:012503.). Another group of authors used positron emission tomography images to estimate the radiation doses given to patients with thyroid cancer(1212 Jentzen W, Freudenberg L, Eising EG, et al. Optimized 124I PET dosimetry protocol for radioiodine therapy of differentiated thyroid cancer. J Nucl Med. 2008;49:1017-23.). Both studies were in agreement, in that it is possible to achieve a considerable reduction in the amount of radiometric data required for providing adequate dosimetry. However, it is possible that more data are needed in the case of tumor dosimetry.

The probe detection and image quantification methods provide similar results in determining radiometric data for planning red-marrow and whole-body dosimetry for thyroid cancer patients without metastatic bone involvement. However, the probe detection method should be used with a certain degree of caution, given that, in some clinical cases, the red-marrow is not the first organ at risk during therapy, especially in patients who present with regional or disseminated diseases. Unlike image quantification, probe detection is unable to identify tumor sites or evaluate the 131I biokinetics within specific organs, such as the kidneys, lungs, and brain, or in tumors surrounding the spinal cord. At our facility, several patients presented to therapy planning with metastases involving or adjacent to the spinal cord with high 131I uptake. Such metastases merit special attention, with restrictions of the absorbed dose being determined according to the dimension of the irradiated area during radionuclide therapy procedures, such as external radiotherapy, such analysis having been the modus operandi for decades. It is also quite common to see patients presenting with lung metastases, a situation in which the lung, rather than the red marrow, is the limiting organ for determining the total amount of 131I to be applied in therapy. Therefore, the evaluation of tumor sites and dose restriction based on 131I biokinetics in a specific organ or tumor cannot be determined only by probe detection, in which the analysis and quantification of nuclear medicine images is the rule. Tailoring the amount of 131I to be administered to a patient based on biokinetics data obtained from probe detection alone could lead to the use of incorrect procedures, with the possibility of causing severe damage to the patient.

From our perspective, there is no doubt that the future of nuclear medicine dosimetry will involve image quantification, given the various advantages of its use in therapy planning, such as restoring the bases of radionuclide therapy, thus avoiding cell damage caused by the delivery of inappropriate radiation doses to a specific organ or tumor.

CONCLUSIONS

There is strong positive agreement between the probe detection and image quantification methods for estimating 131I biokinetics and radiation doses to the red marrow and whole body for patients with metastatic thyroid cancer without metastatic bone involvement. Nevertheless, care should be taken when using the probe detection method, because it is unable to identify tumor sites and critical organs during therapy planning, which could have a negative impact on the adjustment of 131I amounts to be administered.

  • *
    Study conducted at the Instituto do Câncer do Estado de São Paulo Octavio Frias de Oliveira (Icesp) and at Faculdade de Medicina da Universidade de São Paulo (FMUSP), São Paulo, SP, Brazil.

REFERENCES

  • 1
    Luster M, Clarke SE, Dietlein M, et al. Guidelines for radioiodine therapy of differentiated thyroid cancer. Eur J Nucl Med Mol Imaging. 2008;35:1941-59.
  • 2
    Dorn R, Kopp J, Vogt H, et al. Dosimetry-guided radioactive iodine treatment in patients with metastatic differentiated thyroid cancer: largest safe dose using a risk-adapted approach. J Nucl Med. 2003;44:451-6.
  • 3
    Song H, He B, Prideaux A, et al. Lung dosimetry for radioiodine treatment planning in the case of diffuse lung metastases. J Nucl Med. 2006;47:1985-94.
  • 4
    Sgouros G, Song H, Ladenson PW, et al. Lung toxicity in radioiodine therapy of thyroid carcinoma: development of a dose-rate method and dosimetric implications of the 80-mCi rule. J Nucl Med. 2006;47:1977-84.
  • 5
    Lassmann M, Hänscheid H, Chiesa C, et al. EANM Dosimetry Committee series on standard operational procedures for pre-therapeutic dosimetry I: blood and bone marrow dosimetry in differentiated thyroid cancer therapy. Eur J Nucl Med Mol Imaging. 2008;35:1405-12.
  • 6
    Hindorf C, Glatting G, Chiesa C, et al. EANM Dosimetry Committee guidelines for bone marrow and whole-body dosimetry. Eur J Nucl Med Mol Imaging. 2010;37:1238-50.
  • 7
    Stabin MG, Sparks RB, Crowe E. OLINDA/EXM: the second-generation personal computer software for internal dose assessment in nuclear medicine. J Nucl Med. 2005;46:1023-7.
  • 8
    Willegaignon J, Sapienza MT, Buchpiguel CA. Comparison of different dosimetric methods for red marrow absorbed dose calculation in thyroid cancer therapy. Radiat Prot Dosimetry. 2012;149:138-46.
  • 9
    Benua RS, Cicale NR, Sonenberg M, et al. The relation of radioiodine dosimetry to results and complications in the treatment of metastatic thyroid cancer. Am J Roentgenol Radium Ther Nucl Med. 1962;87:171-82.
  • 10
    Willegaignon J, Sapienza MT, Coura Filho GB, et al. Determining thyroid (131)I effective half-life for the treatment planning of Graves' disease. Med Phys. 2013;40:022502.
  • 11
    Willegaignon J, Sapienza MT, Coura-Filho GB, et al. Graves' disease radioiodine-therapy: choosing target absorbed doses for therapy planning. Med Phys. 2014;41:012503.
  • 12
    Jentzen W, Freudenberg L, Eising EG, et al. Optimized 124I PET dosimetry protocol for radioiodine therapy of differentiated thyroid cancer. J Nucl Med. 2008;49:1017-23.

Publication Dates

  • Publication in this collection
    May-Jun 2016

History

  • Received
    04 May 2015
  • Accepted
    06 July 2015
Publicação do Colégio Brasileiro de Radiologia e Diagnóstico por Imagem Av. Paulista, 37 - 7º andar - conjunto 71, 01311-902 - São Paulo - SP, Tel.: +55 11 3372-4541, Fax: 3285-1690, Fax: +55 11 3285-1690 - São Paulo - SP - Brazil
E-mail: radiologiabrasileira@cbr.org.br