Skip to main content
Log in

Characterization of a monolithic device for detection of FRET signals

  • Published:
MRS Online Proceedings Library Aims and scope

Abstract

Fluorescence Resonance Energy Transfer (FRET) is a standard technique used in many medical and biological applications. It involves the detection of transient fluorescent signals coming from the different fluorescent proteins that work in the visible range of the spectrum. Common fluorescent emissions come from the cyan/yellow fluorophores that emit respectively, at 470 nm and 588 nm. In this paper we use optical filters based on multilayered a-SiC:H heterostructures to detect optical signals at these wavelengths. The advantage of this type of sensor is that it does not rely on mechanical parts; it is compact and cost effective. The transducer consists of two heterostructures based on a-SiC:H/a-Si:H optimized for the detection of the fluorescence emissions at wavelengths 470 nm (cyan) and 588 nm (yellow). Both front and back structures were designed to optimize the detection at these wavelengths. Results show that the device photocurrent signal measured under reverse bias and using appropriate steady state optical bias, allows the separate detection of the cyan and yellow fluorescence signals.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

References

  1. D.A LaVan, Terry McGuire, Robert Langer, Nat. Biotechnol. 21 (10), 2003, 1184–1191.

    Article  CAS  Google Scholar 

  2. D. Grace, Medical Product Manufacturing News, 12, 2008, 22–23.

    Google Scholar 

  3. M. A. Vieira, M. Vieira, J. Costa, P. Louro, M. Fernandes, A. Fantoni, Sens. Transd, 9, 2010, 96–120.

    Google Scholar 

  4. P. Louro, A. Fantoni, M. Fernandes, A. Maçarico, R. Schwarz, M. Vieira, J. Non Cryst. Sol., 338-340 (2004) 345–348.

    Article  Google Scholar 

  5. P. Louro, M. Fernandes, J. Costa, M. A Vieira, A. Fantoni, M Vieira, MRS Proc. 2011, 1321, 223–228

    Google Scholar 

Download references

Acknowledgments

This work was supported by FCT (CTS multi annual funding) through the PIDDAC Program funds and PTDC/EEA-ELC/111854/2009.

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Louro, P., Vieira, M., Vieira, M.A. et al. Characterization of a monolithic device for detection of FRET signals. MRS Online Proceedings Library 1426, 187–192 (2012). https://doi.org/10.1557/opl.2012.1261

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1557/opl.2012.1261

Navigation