Abstract
Two-photon interference is an important effect that is tightly related to the quantum nature of light. Recently, it has been shown that the photon bunching from the Hong–Ou–Mandel (HOM) effect can be used for quantum imaging in which sample properties (reflection/transmission amplitude, phase delay, or polarization) can be characterized at the pixel-by-pixel level. In this work, we perform Jones matrix imaging for an unknown object based on two-photon interference. By using a reference metasurface with panels of known polarization responses in pairwise coincidence measurements, the object’s polarization responses at each pixel can be retrieved from the dependence of the coincidence visibility as a function of the reference polarization. The post-selection of coincidence images with specific reference polarization in our approach eliminates the need in switching the incident polarization and thus parallelized optical measurements for Jones matrix characterization. The parallelization in preparing input states, prevalent in any quantum algorithms, is an advantage of adopting two-photon interference in Jones matrix imaging. We believe our work points to the usage of metasurfaces in biological and medical imaging in the quantum optical regime.
1 Introduction
Nanostructured metasurfaces allow manipulation of the different degrees of freedom (DOF) of light with fine resolution [1–3]. Due to their promising capability in bringing down the size, weight, and power of a device, many efforts have been made to adopt metasurfaces for imaging applications with various optical properties, for example, polarization [4–9], phase [10–14], wavelength [15–19], and view depth [20–22]. Compared to conventional cameras that simply project a 3D object into 2D intensity profile, the integration of metasurface into detectors/camera permits the construction of a complex point spread function that is necessary for multidimensional light field imaging [21]. The complex information in the light field can then be used in many applications such as autonomous driving for depth sensing, target recognition and material composition identification for spectral imaging, image contrast enhancement, stress detection for polarimetric imaging, and more recently on implementing neural networks [23, 24] and brain-computer interface [25]. In quantum optics, the manipulation of individual photons, in terms of quantum interference and entanglement, has been a primary interest in the field [26]. The use of metasurfaces in constructing quantum optical sources allows for generating complex entangled states [27–29], while on the detection side metasurfaces offer applications like one-shot state tomography [30]. Among these applications, two-photon interference is an important effect involving two-photon states. In this case, two indistinguishable photons can have two different quantum processes undergoing either destructive or constructive interference to trigger a two-photon coincidence count at two detectors. The resulting interference in coincidence events among two output ports has been observed for spatial and polarization modes, conventionally with a beam splitter, now with metasurfaces in more general scenarios [31–34].
For the application of quantum imaging, coincidence events are measured in a ghost-imaging setting between the signal (imaging) photons and the heralding photons in deciding whether the detected photons on the image should be recorded or not. For example, two independent images can be superimposed through quantum entanglement and obtained respectively by projecting heralding photons onto different states, with applications on quantum edge detection and imaging with entangled photons [35, 36]. In the latest development, it has been shown that two-photon interference and the resulting bunched photon pairs can be used directly for quantum imaging, which either serves as an input light source to enhance the sensitivity of the imaging setup [37] or as a mechanism to sense the change in reflection/transmission amplitude [38] and phase delay [39, 40] at different locations of the object to be imaged. Note that in these imaging schemes, detection of second-order coherence g2 (coincidence count at photon level) directly reveals the effect of two-photon interference. The effect shows up in the form of intensity correlations rather than intensity in classical interference. It can be used to enhance the signal-to-noise ratio in imaging when an entangle-photon source is used [41].
For an object with arbitrary polarization properties, its behavior can be completely described by a complex 2 × 2 Jones matrix that contains 8 unknown real parameters. Conventionally, to generate a system of equations that can be inverted to determine the parameters of the Jones matrix, a series of intensity measurements are required by choosing different combinations of the incident and analyzing polarization states. Excluding the global phase of the Jones matrix, the minimal required number of intensity measurements is 10 with one measurement for each amplitude and two measurements for each relative phase difference [42–44]. Normally, to reduce the error in the retrieved phase difference, over-complete measurements are desired with more measurements than the minimal requirement. As the quantitative measurement of the Jones matrix elements is crucial for the study of light polarization in many applications, significant efforts have been made to simplify the classical approach in Jones matrix characterization with examples including vectorial Fourier ptychography [45, 46] and the method of Fourier space sharing [47, 48]. For the former example, the required number of combinations of the incident and analyzing polarization states is reduced by scanning the incident angle for each configuration. While in the latter example, the contribution from different Jones matrix elements can be isolated and retrieved independently using the concept of Fourier space sharing. In either case, the characterization of the Jones matrix is simplified through post-processing and parallelization of the experimental configurations.
In this work, we have performed Jones matrix imaging for an unknown object based on two-photon interference. Figure 1 shows the schematic of the experiment. The sample is divided into two regions: an object (the “apple”) with unknown transmission polarization responses and a reference metasurface region with nano-structures of known polarization responses. For illustration, Figure 1(a) shows 4 reference panels, labeled as “H”, “D”, “V”, and “A”, passing through different chosen polarizations. When two orthogonal circularly polarized photons are shined onto the whole sample area, a series of raw images can be recorded at individual time frames by a single-photon avalanche diodes (SPAD) camera. By using an SPAD camera, it becomes possible to probe coincidence events between any two locations (pixels) within the image in a high throughput manner. The SPAD camera is now envisioned to be very useful that metasurfaces can process information in parallel and the SPAD camera can record also in parallel in the quantum regime [49]. Each pixel of a raw image has a binary value indicating whether a photon is registered or not. The whole imaging process is then repeated for different time delays between the two photons. From the raw images, a coincidence image with respect to a particular reference panel refers to an array of the number of coincidence events with one photon recorded through any of the object pixels while another is recorded through the reference panel at the same time frame. In such a way, a stack of 4D coincidence images: two spatial degrees of freedom (DOF) plus another two on the choice of the reference polarization and tunable delay is formed, as shown in Figure 1(b). Then, for a particular object pixel, we can plot the second-order coherence g2, as a curve against the tunable time delay for the different reference polarizations. A dip or a peak on such a curve is contributed by the destructive (HOM) or constructive two-photon interference. A series of g2-visibilities (
2 Coincidence imaging scheme
Our imaging scheme starts with two incident pulses having complex coherent state amplitudes αL for the left-handed circular polarization (LCP) and αR for the right-handed circular polarization (RCP) arriving on the sample at the same time. The polarization basis is selected to exploit the Pancharatnam–Berry phase with the reference panels (polarizers) which greatly simplifies the equations in this section. The sample is then imaged by the SPAD camera for different final analyzing polarization selected by a quarter wave plate and a polarizer before the camera. In terms of αL and αR, the output coherent amplitudes arriving at any pixels on the camera can be written as
where an index i (j) is used to iterate pixels that can be traced back to the reference panels (object) while the second index, “L” or “R”, of all the complex transfer amplitudes indicates either LCP or RCP incidence. By selecting all time frames that one photon falls on a specific reference panel while another on any pixels of the object area, a coincidence image is formed with respect to the passing polarization of such reference panel. In terms of the Jones matrix on circular polarization basis, a reference pixel is defined by
ideally as a polarizer where θ
i
is the angle of the passing axis and tref is the overall complex transmission amplitude of the reference pixel. Without losing generality, we consider the final analyzer in probing LCP, we have
Considering the photon statistics directly from the output coherent states α i and α j . Assume all the camera’s detectors have the same detection efficiency η and it does not distinguish photon number (i.e. only differentiate no photon and has photon in the same frame), the coincidence count rate P ij between any pairs of a reference pixel and an object pixel is governed by [34]
where
To evaluate the proposed imaging scheme, an object with enough complexity in the polarization response is required and is assembled here using plasmonic nano-slots in various slot lengths, orientations, and sub-lattice structures. The Jones matrix of an object pixel under consideration here is most generally defined as
where t
j
is the overall complex transmission amplitude of the object pixel j,
with the ballistic single photon count rate for the object pixel written as
Then, the amplitude and the location of interference in the experimental visibility curve in Eq. (6) against θ
i
can be used to extract
where
and
3 Results and discussion
3.1 Sample and setup characterization
Figure 2(a) shows the measured co-linear polarization transmission spectrum of a periodic vertically orientated nano-slot array (inset, θ
i
= 0° for the passing axis) for different slot lengths. The nano-slot array is fabricated on a 50 nm thick silver film on a glass substrate by a focused ion beam (FIB) technique with a periodicity p scaled with the slot length L (p = 1.6L kept fixed). This ratio is selected to avoid overlapping of nano-slots for long slot lengths while maximizing the transmission for short slot lengths. From the measured spectra (solid curves in Figure 2(a)), the nanoslots transmit mostly the polarization component perpendicular to the slot direction [55], with transmittance peaks at 684, 747, and 797 nm for slot lengths 145, 172.62, and 190 nm (solid curves, H-pol), respectively. Note that there is still some small residual transmission (dashed curves) along the slot direction. However, it can be treated as a background as it is much smaller than THH and insensitive to L. Moreover, the L = 145 nm nanoslot array exhibits the largest transmittance ratio (
Figure 2(c) shows the experimental setup for the coincidence measurement. The incident beam from a supercontinuum pulse laser is decomposed by a monochromator to give coherent pulses at 684 nm with a 3 nm bandwidth. It is then split into two beams by a polarization beam splitter with one beam passing through a motorized optical delay line. The two beams then recombine after merging at a second polarization beam splitter. A quarter waveplate (QWP), fast axis at 45° from the vertical, behind the second beam splitter converts the two beams into two orthogonal right-handed and left-handed circular polarization (RCP and LCP) incident light for the metasurface sample. A 100 mm lens then focuses the circularly polarized beams with overlapping spot sizes large enough to cover the whole sample. After passing through the sample, the transmitted beams will be collected by a 10× objective, projected by another QWP and analyzer to LCP, and finally collected by the SPAD camera for coincidence measurement. Here, the required phase randomization needed for the two-photon interference with weak coherent states is realized by the vibrations resulting from the mechanical motion of the optical components along the motorized optical delay line [34]. Figure 2(d) shows the measured second-order coherence g2 plot as a function of optical delay between the reference H and V polarization channels, i.e.
3.2 Polarization-response imaging on metasurfaces
Figure 3 shows the first example of coincidence imaging on one DOF: argument of the off-diagonal element of the Jones matrix
Figure 3(b) shows the two measured differential visibilities plotted against each other for all the object pixels, roughly falling on a circle of radius smaller than unity when higher order correction (Eq. (8)) of
Next, we perform a 2 DOF coincidence imaging example including the sub-lattice structures. Each slot array of the object (red square) now consists of two sets of slot orientations, θ1 and θ2 in a checkerboard pattern, as shown in the SEM image in Figure 4(a). Each slot array gives rise to Jones matrix elements in Eq. (4) where
As a final example, Figure 5 shows the 3 DOF coincidence imaging example with additional control on the transmission amplitude
As mentioned before, conventionally a series of intensity measurements (minimal 10) with different incident polarizations and different polarization analyzers are required to completely determine an unknown 2 × 2 Jones matrix with 7 real number DOF without the global phase [42–44]. For our method, as we have already parallelized different input polarizations using the reference panels, we will only need 3 different cases of final analyzers that reduce the 10 configurations to 3. We expect that by further introducing linear phase gradients (e.g. cascading to a second metasurface) to split the light from the object into different directions for different output polarizations, the number of required experiments can be further suppressed [7, 30]. The freedom in using different designs of meta-atom as the reference panels also allows further generalization of parallelization to other DOF like orbital angular momentum. Compared to Stokes cameras [5–7] which measure the polarization state of scattered light from an object, our approach will be able to measure the response matrix due to the parallelization of input polarizations.
4 Conclusions
In conclusion, we have applied two-photon interference to image the Jones matrix profile of an unknown object using metasurface panels with known polarizations as references in parallel. By using two orthogonal circularly polarized phase-randomized weak coherent pulses with tunable delay as inputs, pair-wise coincidence measurements are performed using images taken by a single-photon avalanche diodes (SPAD) camera. The coincidence between each sub-region in the reference channel and all pixels in the object channel are obtained as a series of coincidence images as a function of reference polarization and optical delay. The change in the coincidence visibility at each object’s location/pixel as a function of reference polarization can then be used to retrieve its polarization properties. Conventionally, determining the Jones matrix of the material requires multiple configurational measurements in switching between the different combinations of incidence and analyzing polarizations. On the contrary, for our work, the post-selection of coincidence images with specific reference polarization in our approach eliminates the need in switching the incident polarization. Thus, the characterization of the Jones matrix is efficient through the parallelization of the incident configuration and image analysis, offering great potential in biological and medical imaging applications. Such a coincidence imaging scheme has the potential in simplifying the Jones matrix imaging process. For the future extension, the switching of analyzing polarization in the current work can be further considered if more complicated Jones matrix imaging than the current work is to be performed.
Funding source: Research Grants Council, University Grants Committee
Award Identifier / Grant number: 16304020, 16306521, C6013-18G, AoE/P-502/20, C6012-20G
Funding source: Croucher Foundation
Award Identifier / Grant number: CAS20SC01
-
Author contributions: J.L. conceived the idea and initiated the project. T.K.Y. designed the samples. J.X. fabricated the samples. T.K.Y., and H.L. performed the measurements. T.K.Y., W.Y.T., and J.L. analyzed the data. T.K.Y., H.L., and J.L. developed the analytic models. All authors discussed the results and commented on the manuscript.
-
Research funding: The authors are grateful for financial support from the Hong Kong RGC (16304020, 16306521, C6013-18G, AoEP-502/20, C6012-20G) and from Croucher Foundation (CAS20SC01).
-
Conflict of interest statement: The authors declare no conflicts of interest regarding this article.
References
[1] H. T. Chen, A. J. Taylor, and N. Yu, “A review of metasurfaces: physics and applications,” Rep. Prog. Phys., vol. 79, no. 7, p. 076401, 2016. https://doi.org/10.1088/0034-4885/79/7/076401.Search in Google Scholar PubMed
[2] F. Ding, A. Pors, and S. I. Bozhevolnyi, “Gradient metasurfaces: a review of fundamentals and applications,” Rep. Prog. Phys., vol. 81, no. 2, p. 026401, 2017. https://doi.org/10.1088/1361-6633/aa8732.Search in Google Scholar PubMed
[3] D. Lee, S. So, G. Hu, et al.., “Hyperbolic metamaterials: fusing artificial structures to natural 2D materials,” eLight, vol. 2, no. 1, pp. 1–23, 2022. https://doi.org/10.1186/s43593-021-00008-6.Search in Google Scholar
[4] M. Khorasaninejad, W. T. Chen, A. Y. Zhu, et al.., “Multispectral chiral imaging with a metalens,” Nano Lett., vol. 16, no. 7, pp. 4595–4600, 2016. https://doi.org/10.1021/acs.nanolett.6b01897.Search in Google Scholar PubMed
[5] E. Arbabi, S. M. Kamali, A. Arbabi, and A. Faraon, “Full-Stokes imaging polarimetry using dielectric metasurfaces,” ACS Photonics, vol. 5, no. 8, pp. 3132–3140, 2018. https://doi.org/10.1021/acsphotonics.8b00362.Search in Google Scholar
[6] Z. Yang, Z. Wang, Y. Wang, et al.., “Generalized Hartmann-Shack array of dielectric metalens sub-arrays for polarimetric beam profiling,” Nat. Commun., vol. 9, no. 1, pp. 1–7, 2018. https://doi.org/10.1038/s41467-018-07056-6.Search in Google Scholar PubMed PubMed Central
[7] N. A. Rubin, G. D’Aversa, P. Chevalier, Z. Shi, W. T. Chen, and F. Capasso, “Matrix Fourier optics enables a compact full-Stokes polarization camera,” Science, vol. 365, no. 6448, p. eaax1839, 2019. https://doi.org/10.1126/science.aax1839.Search in Google Scholar PubMed
[8] N. A. Rubin, P. Chevalier, M. Juhl, M. Tamagnone, R. Chipman, and F. Capasso, “Imaging polarimetry through metasurface polarization gratings,” Opt. Express, vol. 30, no. 6, pp. 9389–9412, 2022. https://doi.org/10.1364/oe.450941.Search in Google Scholar
[9] L. Li, J. Wang, L. Kang, et al.., “Monolithic full-Stokes near-infrared polarimetry with chiral plasmonic metasurface integrated graphene–silicon photodetector,” ACS Nano, vol. 14, no. 12, pp. 16634–16642, 2020. https://doi.org/10.1021/acsnano.0c00724.Search in Google Scholar PubMed
[10] H. Kwon, E. Arbabi, S. M. Kamali, M. Faraji-Dana, and A. Faraon, “Single-shot quantitative phase gradient microscopy using a system of multifunctional metasurfaces,” Nat. Photonics, vol. 14, no. 2, pp. 109–114, 2020. https://doi.org/10.1038/s41566-019-0536-x.Search in Google Scholar
[11] E. Engay, D. Huo, R. Malureanu, A. I. Bunea, and A. Lavrinenko, “Polarization-dependent all-dielectric metasurface for single-shot quantitative phase imaging,” Nano Lett., vol. 21, no. 9, pp. 3820–3826, 2021. https://doi.org/10.1021/acs.nanolett.1c00190.Search in Google Scholar PubMed
[12] E. Balaur, G. A. Cadenazzi, N. Anthony, et al.., “Plasmon-induced enhancement of ptychographic phase microscopy via sub-surface nanoaperture arrays,” Nat. Photonics, vol. 15, no. 3, pp. 222–229, 2021. https://doi.org/10.1038/s41566-020-00752-0.Search in Google Scholar
[13] L. Wesemann, J. Rickett, T. J. Davis, and A. Roberts, “Real-time phase imaging with an asymmetric transfer function metasurface,” ACS Photonics, vol. 9, no. 5, pp. 1803–1807, 2022. https://doi.org/10.1021/acsphotonics.2c00346.Search in Google Scholar
[14] P. Bouchal, L. Štrbková, Z. Dostál, R. Chmelík, and Z. Bouchal, “Geometric-phase microscopy for quantitative phase imaging of isotropic, birefringent and space-variant polarization samples,” Sci. Rep., vol. 9, no. 1, pp. 1–11, 2019. https://doi.org/10.1038/s41598-019-40441-9.Search in Google Scholar PubMed PubMed Central
[15] M. Faraji-Dana, E. Arbabi, A. Arbabi, S. M. Kamali, H. Kwon, and A. Faraon, “Compact folded metasurface spectrometer,” Nat. Commun., vol. 9, no. 1, pp. 1–8, 2018. https://doi.org/10.1038/s41467-018-06495-5.Search in Google Scholar PubMed PubMed Central
[16] M. Faraji-Dana, E. Arbabi, H. Kwon, et al.., “Hyperspectral imager with folded metasurface optics,” ACS Photonics, vol. 6, no. 8, pp. 2161–2167, 2019. https://doi.org/10.1021/acsphotonics.9b00744.Search in Google Scholar
[17] F. Yesilkoy, E. R. Arvelo, Y. Jahani, et al.., “Ultrasensitive hyperspectral imaging and biodetection enabled by dielectric metasurfaces,” Nat. Photonics, vol. 13, no. 6, pp. 390–396, 2019. https://doi.org/10.1038/s41566-019-0394-6.Search in Google Scholar
[18] T. Xie, F. Zhang, M. Pu, Y. Guo, and X. Luo, “Integrated multispectral real-time imaging system based on metasurfaces,” Opt. Express, vol. 28, no. 24, pp. 36445–36454, 2020. https://doi.org/10.1364/oe.411353.Search in Google Scholar PubMed
[19] A. McClung, S. Samudrala, M. Torfeh, M. Mansouree, and A. Arbabi, “Snapshot spectral imaging with parallel metasystems,” Sci. Adv., vol. 6, no. 38, p. eabc7646, 2020. https://doi.org/10.1126/sciadv.abc7646.Search in Google Scholar PubMed PubMed Central
[20] C. Jin, M. Afsharnia, R. Berlich, et al.., “Dielectric metasurfaces for distance measurements and three-dimensional imaging,” Adv. Photonics, vol. 1, no. 3, p. 036001, 2019. https://doi.org/10.1117/1.ap.1.3.036001.Search in Google Scholar
[21] R. J. Lin, V. C. Su, S. Wang, et al.., “Achromatic metalens array for full-colour light-field imaging,” Nat. Nanotechnol., vol. 14, no. 3, pp. 227–231, 2019. https://doi.org/10.1038/s41565-018-0347-0.Search in Google Scholar PubMed
[22] F. Zhao, R. Lu, X. Chen, et al.., “Metalens‐assisted system for underwater imaging,” Laser Photon. Rev., vol. 15, no. 8, p. 2100097, 2021. https://doi.org/10.1002/lpor.202100097.Search in Google Scholar
[23] X. Lin, Y. Rivenson, N. T. Yardimci, et al.., “All-optical machine learning using diffractive deep neural networks,” Science, vol. 361, no. 6406, pp. 1004–1008, 2018. https://doi.org/10.1126/science.aat8084.Search in Google Scholar PubMed
[24] L. Li, H. Zhao, C. Liu, L. Li, and T. J. Cui, “Intelligent metasurfaces: control, communication and computing,” eLight, vol. 2, p. 7, 2022. https://doi.org/10.1186/s43593-022-00013-3.Search in Google Scholar
[25] Q. Ma, W. Gao, Q. Xiao, et al.., “Directly wireless communication of human minds via non-invasive brain-computer-metasurface platform,” eLight, vol. 2, p. 11, 2022. https://doi.org/10.1186/s43593-022-00019-x.Search in Google Scholar
[26] A. S. Solntsev, G. S. Agarwal, and Y. S. Kivshar, “Metasurfaces for quantum photonics,” Nat. Photonics, vol. 15, no. 5, pp. 327–336, 2021. https://doi.org/10.1038/s41566-021-00793-z.Search in Google Scholar
[27] L. Li, Z. Liu, X. Ren, et al.., “Metalens-array–based high-dimensional and multiphoton quantum source,” Science, vol. 368, no. 6498, pp. 1487–1490, 2020. https://doi.org/10.1126/science.aba9779.Search in Google Scholar PubMed
[28] Y. Ming, W. Zhang, J. Tang, et al.., “Photonic entanglement based on nonlinear metamaterials,” Laser Photon. Rev., vol. 14, no. 5, p. 1900146, 2020. https://doi.org/10.1002/lpor.202070028.Search in Google Scholar
[29] J. Perczel, J. Borregaard, D. E. Chang, S. F. Yelin, and M. D. Lukin, “Topological quantum optics using atomlike emitter arrays coupled to photonic crystals,” Phys. Rev. Lett., vol. 124, no. 8, p. 083603, 2020. https://doi.org/10.1103/physrevlett.124.083603.Search in Google Scholar
[30] K. Wang, J. G. Titchener, S. S. Kruk, et al.., “Quantum metasurface for multiphoton interference and state reconstruction,” Science, vol. 361, no. 6407, pp. 1104–1108, 2018. https://doi.org/10.1126/science.aat8196.Search in Google Scholar PubMed
[31] N. M. Estakhri and T. B. Norris, “Tunable quantum two-photon interference with reconfigurable metasurfaces using phase-change materials,” Opt. Express, vol. 29, no. 10, pp. 14245–14259, 2021. https://doi.org/10.1364/oe.419892.Search in Google Scholar PubMed
[32] Q. Li, W. Bao, Z. Nie, et al.., “A non-unitary metasurface enables continuous control of quantum photon–photon interactions from bosonic to fermionic,” Nat. Photonics, vol. 15, no. 4, pp. 267–271, 2021. https://doi.org/10.1038/s41566-021-00762-6.Search in Google Scholar
[33] P. Georgi, M. Massaro, K. H. Luo, et al.., “Metasurface interferometry toward quantum sensors,” Light: Sci. Appl., vol. 8, no. 1, pp. 1–7, 2019. https://doi.org/10.1038/s41377-019-0182-6.Search in Google Scholar PubMed PubMed Central
[34] T. K. Yung, J. Xi, H. Liang, et al.., “Polarization coincidence images from metasurfaces with HOM-type interference,” Iscience, vol. 25, no. 4, p. 104155, 2022. https://doi.org/10.1016/j.isci.2022.104155.Search in Google Scholar PubMed PubMed Central
[35] J. Zhou, S. Liu, H. Qian, et al.., “Metasurface enabled quantum edge detection,” Sci. Adv., vol. 6, no. 51, p. eabc4385, 2020. https://doi.org/10.1126/sciadv.abc4385.Search in Google Scholar PubMed PubMed Central
[36] C. Altuzarra, A. Lyons, G. Yuan, et al.., “Imaging of polarization-sensitive metasurfaces with quantum entanglement,” Phys. Rev. A, vol. 99, no. 2, p. 020101, 2019. https://doi.org/10.1103/physreva.99.020101.Search in Google Scholar
[37] T. Ono, R. Okamoto, and S. Takeuchi, “An entanglement-enhanced microscope,” Nat. Commun., vol. 4, no. 1, pp. 1–7, 2013. https://doi.org/10.1038/ncomms3426.Search in Google Scholar PubMed
[38] Z. Ibarra-Borja, C. Sevilla-Gutiérrez, R. Ramírez-Alarcón, H. Cruz-Ramírez, and A. B. U’Ren, “Experimental demonstration of full-field quantum optical coherence tomography,” Photon. Res., vol. 8, no. 1, pp. 51–56, 2020. https://doi.org/10.1364/prj.8.000051.Search in Google Scholar
[39] B. Ndagano, H. Defienne, D. Branford, et al.., “Quantum microscopy based on Hong–Ou–Mandel interference,” Nat. Photonics, vol. 16, pp. 1–6, 2022. https://doi.org/10.1038/s41566-022-00980-6.Search in Google Scholar
[40] R. Murray and A. Lyons, “Two-photon interference LiDAR imaging,” Opt. Express, vol. 30, no. 15, pp. 27164–27170, 2022. https://doi.org/10.1364/oe.461248.Search in Google Scholar PubMed
[41] G. Brida, M. Genovese, and I. R. Berchera, “Experimental realization of sub-shot-noise quantum imaging,” Nat. Photonics, vol. 4, no. 4, pp. 227–230, 2010. https://doi.org/10.1038/nphoton.2010.29.Search in Google Scholar
[42] J. del Hoyo, L. M. Sanchez-Brea, and A. Soria-Garcia, “Calibration method to determine the complete Jones matrix of SLMs,” Opt Laser. Eng., vol. 151, p. 106914, 2022. https://doi.org/10.1016/j.optlaseng.2021.106914.Search in Google Scholar
[43] J. Park, H. Yu, J. H. Park, and Y. Park, “LCD panel characterization by measuring full Jones matrix of individual pixels using polarization-sensitive digital holographic microscopy,” Opt. Express, vol. 22, no. 20, pp. 24304–24311, 2014. https://doi.org/10.1364/oe.22.024304.Search in Google Scholar
[44] V. Tiwari, S. K. Gautam, D. N. Naik, R. K. Singh, and N. S. Bisht, “Characterization of a spatial light modulator using polarization-sensitive digital holography,” Appl. Opt., vol. 59, no. 7, pp. 2024–2030, 2020. https://doi.org/10.1364/ao.380572.Search in Google Scholar
[45] X. Dai, S. Xu, X. Yang, et al.., “Quantitative Jones matrix imaging using vectorial Fourier ptychography,” Biomed. Opt Express, vol. 13, no. 3, pp. 1457–1470, 2022. https://doi.org/10.1364/boe.448804.Search in Google Scholar PubMed PubMed Central
[46] K. Park, T. D. Yang, D. Seo, et al.., “Jones matrix microscopy for living eukaryotic cells,” ACS Photonics, vol. 8, no. 10, pp. 3042–3050, 2021. https://doi.org/10.1021/acsphotonics.1c01064.Search in Google Scholar
[47] M. M. Sreelal, R. V. Vinu, and R. K. Singh, “Jones matrix microscopy from a single-shot intensity measurement,” Opt. Lett., vol. 42, no. 24, pp. 5194–5197, 2017. https://doi.org/10.1364/ol.42.005194.Search in Google Scholar PubMed
[48] G. X. Chen, Y. Y. Zhang, Y. Yang, H. Y. Huang, Q. Y. Yue, and C. S. Guo, “Compact common-path polarisation holographic microscope for measuring spatially-resolved Jones matrix parameters of dynamic samples in microfluidics,” Opt. Commun., vol. 503, p. 127460, 2022. https://doi.org/10.1016/j.optcom.2021.127460.Search in Google Scholar
[49] K. Wang, M. Chekhova, and Y. Kivshar, “Metasurfaces,” Phys. Today, vol. 75, pp. 8–38, 2022. https://doi.org/10.1063/pt.3.5062.Search in Google Scholar
[50] H. Kim, O. Kwon, and H. S. Moon, “Two-photon interferences of weak coherent lights,” Sci. Rep., vol. 11, no. 1, pp. 1–11, 2021. https://doi.org/10.1038/s41598-021-99804-w.Search in Google Scholar PubMed PubMed Central
[51] A. Aragoneses, N. T. Islam, M. Eggleston, A. Lezama, J. Kim, and D. J. Gauthier, “Bounding the outcome of a two-photon interference measurement using weak coherent states,” Opt. Lett., vol. 43, no. 16, pp. 3806–3809, 2018. https://doi.org/10.1364/ol.43.003806.Search in Google Scholar
[52] Y. Z. Zhang, K. Wei, and F. Xu, “Generalized Hong-Ou-Mandel quantum interference with phase-randomized weak coherent states,” Phys. Rev. A, vol. 101, no. 3, p. 033823, 2020. https://doi.org/10.1103/physreva.101.033823.Search in Google Scholar
[53] F. Grosshans, G. Van Assche, J. Wenger, R. Brouri, N. J. Cerf, and P. Grangier, “Quantum key distribution using Gaussian-modulated coherent states,” Nature, vol. 421, no. 6920, pp. 238–241, 2003. https://doi.org/10.1038/nature01289.Search in Google Scholar PubMed
[54] B. Qi, L. L. Huang, L. Qian, and H. K. Lo, “Experimental study on the Gaussian-modulated coherent-state quantum key distribution over standard telecommunication fibers,” Phys. Rev. A, vol. 76, no. 5, p. 052323, 2007. https://doi.org/10.1103/physreva.76.052323.Search in Google Scholar
[55] L. Lin, L. B. Hande, and A. Roberts, “Resonant nanometric cross-shaped apertures: single apertures versus periodic arrays,” Appl. Phys. Lett., vol. 95, no. 20, p. 201116, 2009. https://doi.org/10.1063/1.3267080.Search in Google Scholar
Supplementary Material
The online version of this article offers supplementary material (https://doi.org/10.1515/nanoph-2022-0499).
© 2022 the author(s), published by De Gruyter, Berlin/Boston
This work is licensed under the Creative Commons Attribution 4.0 International License.