Skip to main content
Advertisement
Browse Subject Areas
?

Click through the PLOS taxonomy to find articles in your field.

For more information about PLOS Subject Areas, click here.

  • Loading metrics

Effect of repeated-sprints on the reliability of short-term parasympathetic reactivation

  • Matteo Bonato,

    Roles Conceptualization, Data curation, Formal analysis, Investigation, Methodology, Software, Validation, Visualization, Writing – original draft, Writing – review & editing

    Affiliation Department of Biomedical Sciences for Health, Università degli Studi di Milano, Milan, Italy

  • Andrea Meloni,

    Roles Data curation, Formal analysis, Investigation, Methodology, Software, Validation, Visualization, Writing – original draft, Writing – review & editing

    Affiliation Department of Biomedical Sciences for Health, Università degli Studi di Milano, Milan, Italy

  • Giampiero Merati,

    Roles Formal analysis, Funding acquisition, Software, Validation, Visualization, Writing – original draft, Writing – review & editing

    Affiliations Department of Biomedical Sciences for Health, Università degli Studi di Milano, Milan, Italy, IRCCS Fondazione Don Carlo Gnocchi, Milan, Italy

  • Antonio La Torre,

    Roles Funding acquisition, Validation, Visualization, Writing – original draft, Writing – review & editing

    Affiliations Department of Biomedical Sciences for Health, Università degli Studi di Milano, Milan, Italy, IRCCS Istituto Ortopedico Galeazzi, Milan, Italy

  • Luca Agnello,

    Roles Conceptualization, Data curation, Formal analysis, Funding acquisition, Investigation, Methodology, Software, Validation, Visualization, Writing – original draft, Writing – review & editing

    Affiliation Department of Biomedical Sciences for Health, Università degli Studi di Milano, Milan, Italy

  • Gianluca Vernillo

    Roles Conceptualization, Data curation, Formal analysis, Funding acquisition, Investigation, Methodology, Project administration, Resources, Software, Supervision, Validation, Visualization, Writing – original draft, Writing – review & editing

    gianluca.vernillo@unimi.it

    Affiliations Department of Biomedical Sciences for Health, Università degli Studi di Milano, Milan, Italy, Human Performance Laboratory, Faculty of Kinesiology, University of Calgary, Calgary, Canada

Abstract

This study determined the reliability of post-exercise heart rate recovery (HRR) and vagal-related HR variability (HRV) after repeated-sprints (RSs), and contrasted it with the smallest worthwhile change (SWC) of these indices. Fourteen healthy male participants performed on four occasions, separated by 7 days, five 30-m sprints interspersed by 25-s of recovery. Post-exercise HR during 10 min of seated rest was measured. HRR during the first 60-s of recovery was computed (HRR60s). HRV indices were calculated in time and frequency domains during the last 5-min of the recovery. Absolute and relative reliability were assessed by typical error of measurement expressed as coefficient of variation (CV) and intraclass correlation coefficients (ICCs), respectively. Sensitivity was assessed comparing SWC to the typical error of measurement. CV ranged from 3.6% to 13.5% and from 6.3% to 109.2% for the HRR and HRV indices, respectively. ICCs were from 0.78 to 0.96 and from 0.76 to 0.92, respectively. HRR and HRV indices showed large discrepancies reliability. HRR60s and the square root of the mean sum of the squared differences between R-R intervals presented the highest levels of both absolute and relative reliability. However, SWC was lower than the typical error of measurement, indicating insufficient sensitivity to confidently detect small, but meaningful, changes in HRR and HRV indices.

Introduction

Repeated-sprints exercise (RSE) is characterized by short-duration sprints at supramaximal intensities interspersed with brief recoveries [1,2]. Through the years, RSE has piqued the interest of the scientific community because it may offer a viable alternative to classically prescribed aerobic training protocols and it is therefore considered a reliable way to induce metabolic adaptations in human skeletal muscle [1,2]. Despite the time course of postexercise heart rate (HR) recovery (HRR) and variability (HRV) is acutely impaired after RSE [35], our group recently observed that 8-weeks of RS training might have a significant and positive effect on the short-term post exercise parasympathetic reactivation [6]. Indeed, in nine healthy participants who performed 18 maximal all-out 15-m sprints interspersed with 17 s of passive recovery, 3 times a week for 8 weeks, postexercise HRR and HRV indices improved when compared to a control group that performed normal, daily physical activities [6].

The evaluation of the time course of postexercise HRR and HRV is considered an accurate non-invasive method to monitor training status. This assessment reflects the general hemodynamic adjustments in relation to body position, blood pressure regulation and meta-baroflex activity, which partly drives sympathetic withdrawal and parasympathetic reactivation and it has extensively been used to predict exercise performance and cardiovascular recovery after training [7,8]. Indeed, the autonomic nervous system may play a role in the training response [9] and it may further provide information regarding the physiological adaptation occurring as a consequence of a given training stimulus [8]. This has been conducted at rest [10], during exercise [11] and throughout the recovery period [4,10,12]. Interestingly, resting cardiac parasympathetic activity is related to cardiorespiratory fitness [9,13,14]. Further, Buchheit [7] argued that measures of HRR and HRV can be used (i) to assess acute fatigue/recovery responses to isolated aerobic-oriented training sessions, and (ii) to inform on both positive and negative adaptations to aerobic oriented training blocks. Accordingly, the reliability (i.e. the degree of change in a particular measure when repeated on different occasions, but in similar conditions [15]) of HRR and HRV measurements as part of sport, physiological and clinical research is very important, in order to allow rigorous evaluation of adaptation to training programs [16] and, therefore, it has been frequently investigated. However, an adequate consensus has not been fully reached since studies on healthy populations have reported low-to-moderate reliability of HRR and HRV indices at rest and after submaximal or maximal exercises [1721]. As such, results of reliability studies are heterogeneous, and dependent on a number of factors such as (i) the experimental intervention, (ii) the signal selection and analysis, and (iii) the statistical analysis used [16,21].

However, the reliability of HRR and HRV indices after an RSE has not been tested yet. We therefore reasoned that without prior knowledge of the between test reliability, interpretation of any information about changes in the cardiac parasympathetic reactivation after an RSE is limited. Indeed, despite we previously showed that changes in HRR and HRV indices could be detected after an RS training [6], and thus the smallest worthwhile change (SWC) could be interpreted as real within acceptable limits of probability [22,23], to assess the usefulness of parasympathetic reactivation measurements after RSE it is important to compare the SWC to the reliability data for the considered indices. This would be of great importance for strength and conditioning coaches, as well as practitioners, in order to avoid bias interpretation when assessing changes in the parasympathetic reactivation indices after RS training protocol and to be able to present a change as meaningful.

Since limited reliability and sensitivity data on parasympathetic reactivation after RSE are available, the main aim of this study was to establish the short-term reliability, as well as the sensitivity, of post-exercise parasympathetic reactivation measures after RSE.

Methods

Participants

Fourteen healthy moderately-trained males (mean ± SD; age: 24 ± 4 yrs, stature: 181 ± 5 cm, body mass: 74 ± 7 kg, BMI: 23 ± 1 kg·m-2, training 8 ± 2 h per week) volunteered to participate in this study. All participants were involved in various intermittent activities (e.g. basketball and soccer) and they were all familiar with exercise testing. None of the participants had any history or clinical signs of cardiovascular or pulmonary diseases. Each participant gave written informed consent prior to the study. The study was approved by the local ethical committee (protocol #58/15, Università degli Studi di Milano, Italy) and it was performed according to the ethical standards laid out inthe Helsinki Declaration for experimentation on human participants.

Procedures

Participants completed on four occasions, separated by 7 days, an RSE. They were asked to refrain from intense physical activity in the 48-h preceding each testing session. In order to minimize circadian effects, all RSEs were conducted at same hour of the day (± 15 min). All participants were allowed to maintain their usual diet throughout the study, but were asked to consume their last meal at least 3 h before each test session and to refrain from consuming drinks containing caffeine for at least 12 h preceding the effort. Smokers were not included in the present study. Further, water consumption was restricted at the start of each RSE since it has been shown that water intake accelerates post-exercise cardiac vagal reactivation [24].

Repeated-sprints exercise

RSE was performed on an indoor synthetic track where the ambient temperature ranged from 18 to 20°C. The RSE consisted of five 30-m linear sprints interspersed by 25 s of active recovery [6]. To avoid any protective pacing strategy, each subject completed a preliminary single sprint that was considered as the criterion score during the RSE. Specifically, if the performance time in the first sprint of the RSE was worse than the criterion score (i.e. > 2.5%), the test was immediately terminated and participants were required to repeat the RSE with a higher effort after a 5-min rest [25]. Five seconds before starting each sprint, the participants were told to assume the ready position, that was standardized for each subject throughout the protocol [26], and to wait for the start signal, which was announced by a countdown given by the experimenter. Strong verbal encouragement was provided to each participant during all sprints. An electronic twin-beam photocell system (Microgate, Bolzano, Italy) was mounted at a fixed height (1.2 m from the floor [27]) to record each RS with a precision of 0.01 s. The sum of times for all sprint repetitions [2] and the percentage sprint decrement [Sdec, 100—(total time/ideal time × 100), ideal time = 5 × best time] were then calculated. Sdec is considered the most valid and reliable method to quantify fatigue in RS testing [28].

Beat-to-beat HR analysis

Materials and data treatment.

A Polar S810 HR monitor (Polar Electro, Kempele, Finland) continuously recorded beat-to-beat HR at a 1-ms time resolution [29] by means of an electrode transmitter belt (T61, Polar Electro) that was fitted to the chest of each subject after application of conductive gel. All R-R series recorded by the HR monitor were extracted on a personal computer with the processing program (Polar precision performance SW 5, Polar Electro). Occasional ectopic beats were visually identified and manually replaced with interpolated adjacent R-R interval values.

Postexercise HRR assessment

Parasympathetic nervous system reactivation was assessed during the 10-min period after the RSE. On completing the RSE, the participants were immediately asked to sit on a chair. Time interval between the end of the RSE and sitting down was < 5 s. Particular attention was paid to this detail because differences in body posture have been shown to result in different absolute HRR values [30]. Peak HR (HRpeak) was considered as the highest RR-interval value reached at the end of the RSE. As previously described [6], HRR was calculated by computing the absolute difference between the peak HR retained at the end of exercise (mean of 5 s—HRpeak) and the HR recorded following 60 s of recovery (HRR60s) and by taking the time constant of the HR decay obtained by fitting the 10-min postexercise HRR into a first-order exponential decay curve (HRRτ).

Short-term resting HRV analysis

HRV analyses of the last 5 min of the 10-min recovery period with the subject in the sitting-resting position were performed to ensure data stability. We did not control the respiratory rate in this study sample to not perturb the natural return of HR to baseline and to enhance the applicability of our results in the field [31]. However, the respiratory rate was always within the HF range (> 0.15–0.40 Hz) and did not differ significantly during the last 5 min of recovery [3]. Further, vagal-related HRV indices during spontaneous and metronome-guided breathing differ little [32] and do not seem to influence the reliability of HRV indices [33], though no unanimous consensus exists [34]. As previously described [6], HRV values were restricted to the natural logarithm of the (i) square root of the mean sum of the squared differences between R-R intervals (Ln rMSSD5-10min); (ii) standard deviation of R-R intervals (Ln SDNN5-10min); (iii) high frequency power (Ln HF5-10min), and (iv) percentage of change in successive normal sinus (NN) intervals with increases lower than 50 ms (pNNx+5-10min) since pNNx with x < 50 ms is more sensitive to characterise cardiac response to exercise and provides useful information about the short-term control of sinus rhythm dynamics [35]. All analyses were performed with Kubios HRV Analysis Software v2.2 (Biosignal analysis and medical imaging group, University of Eastern Finland, Finland) [36], excepted for pNNx+5-10min for which a customized software was used (LabVIEW National Instruments, Version 7.1, Austin, TX).

Statistical analysis

Data are presented as mean ± standard deviation, 90% confidence interval, and range. To examine the reliability of RSE over the 4 consecutive trials, systematic changes in the mean across the RSE sessions (i.e. RS 1, RS 2, RS 3, and RS 4) were primarily assessed using a repeated-measures ANOVA, with the Bonferroni post-hoc test procedures and the level of significance sat at P < 0.05. Sphericity was checked by Mauchly’s test and P values were modified with Greenhouse-Geisser or Huyn-Feldt corrections if necessary. The analysis was carried out with IBMTM SPSSTM Statistics (version 22.0.0, IBM Corp., Somers, New York, USA). Then, relative and absolute reliability was assessed using the Intraclass Correlation Coefficient (ICC) and the typical error of measurement as the coefficient of variance (CV), respectively [37]. Relative reliability represents the degree to which individuals maintain their position in a sample with repeated measurements. Absolute reliability is the degree to which repeated measurements vary for individuals [38]. We used a specifically designed spreadsheet (http://sportssci.org) that provides reliability statistics for consecutive pairs of trials for each participant when there are at least 2 trials. In this spreadsheet, all analyses were performed on log-transformed data to reduce bias arising from non-uniformity of error [11]. The sensitivity (i.e. signal to noise ratio) was established comparing the smallest worthwhile change (0.2 × between participant’ standard deviation) with typical error of measurement [22] associated with RS 1, RS 2, RS 3, and RS 4.

Results

RSE

Sdec scores were 4.3 ± 2.2% (range: 1.7–10.4%), 4.3 ± 1.8% (2.4–8.7%), 4.2 ± 2.2% (2.0–10.0%) and 4.5 ± 2.4% (1.4–9.5%) (Fig 1A); whereas total sprints time were 23.1 ± 0.7 s (21.8–24.0 s), 23.1 ± 0.8 s (21.9–24.0 s), 23.0 ± 1.0 s (21.3–23.8 s) and 23.3 ± 21.2 s (21.4–24.8 s) for the RS 1, RS 2, RS 3 and RS 4 conditions, respectively (Fig 1B). There was no significant session effect for any of the measures (P > 0.05).

thumbnail
Fig 1. Performance in the repeated-sprint exercise.

Performance is expressed as percentage sprint decrement (Sdec, Panel A) and total sprints time (Panel B) for the 14 participants on four RS sessions separated by one week (i.e. RS 1, RS 2, RS 3, and RS 4). Mean and individual values are also presented.

https://doi.org/10.1371/journal.pone.0192231.g001

Reliability of postexercise HRR and short-term resting HRV indices

HRR and HRV values over the 4 consecutive RSEs, as well as the sensitivity data, are reported in Table 1. There was no significant session effect for any of the measures (P > 0.05). The typical error exceeded the SWC for both the HRR and HRV indices.

thumbnail
Table 1. Mean ± SD of the heart rate recovery and variability indices on four RS sessions separated by one week (i.e. RS 1, RS 2, RS 3, and RS 4).

https://doi.org/10.1371/journal.pone.0192231.t001

Reliability of HRR and HRV indices following RSEs is presented in Table 2. Mean ICC values range from 0.78 to 0.96 and from 0.76 to 0.92 for the HRR and HRV indices, respectively. Mean CV values from 3.6% to 13.5% and from 6.3% to 109.2%, respectively.

thumbnail
Table 2. Measures of relative [Intraclass Correlation Coefficient (ICC), (90% confidence interval)] and absolute [typical error of measurement as the coefficient of variance (CV), (90% confidence interval)] reliability of the heart rate recovery and variability indices on four RS sessions separated by one week (i.e. RS 1, RS 2, RS 3, and RS 4).

https://doi.org/10.1371/journal.pone.0192231.t002

Discussion

This study compared the relative and absolute reliability as well as the sensitivity of parasympathetic-mediated HR-derived indices after RSE. The results provide evidence that short-term reliability of post-exercise parasympathetic reactivation indices (i.e. HRR and HRV) showed large discrepancies in markers of reliability, in line with previous studies on HRR and HRV indices both at rest and after (sub)maximal exercises [1721]. Further, based on the analysis of the sensitivity, TE consistently exceeded the SWC for both the HRR and HRV indices. Therefore, RSE does not provide sufficient sensitivity to assess training-induced changes in HRR and HRV indices after RSE.

The CV values of HRR60s and HRV indices found in the present study showed good relative and absolute reliability. However, they were lower compared to what reported by Al Haddad et al. following supramaximal exercise [18]. This difference might be related to the different nature of the exercise protocols used. Indeed, Al Haddad et al. [18] used a Wingate test as supramaximal exercise that probably elicited a greater anaerobic contribution compared to our RSE model, resulting in a greater autonomic perturbation and, thus, in a worse reliability of the HRV indices.

Further, we assessed ICC as estimation of the percentage of the observed score variance that is attributable to the true score variance [37]. The higher the ICC, the higher the relative reliability, and the lower the influence of measurement error. The ICCs of HRR and HRV indices in the present study was in the range of the ICCs reported in other studies [1721]. An interesting result was the high relative reliability of HRR60s and Ln rMSSD5-10min (Table 2), the main HRR index to monitor positive changes in high intensity exercises performance [39] and the more appropriate HRV index to monitor athletes in the field [7], respectively. However, the ICC does not provide an index of the expected trial-to-trial noise in the data; rather it reflects the ability of a measure to be differentiated between individuals [37]. Therefore, it was argued that the CV (i.e. the typical error of measurement as the coefficient of variance) seems to be the most appropriate measure of reliability, because it represents the noise occurring from trial-to-trial [15]. A more salient fact was the poor absolute reliability of both pNN20+5-10min and pNN10+5-10min, though they are more sensitive indices to characterize cardiac response to exercise, providing useful information about the short-term control of sinus rhythm dynamics [35]. The fact that the pNNx family reflects the vagal modulation [35], that is highly impaired after RSE [35,40], probably contributes to the observed values.

However, CV as measure of absolute reliability does not give any information on whether the reliability is acceptable or not [23]. Indeed, the usefulness of a measurement is its ability to detect systematic changes at individual and group level [15]. This measurement characteristic can be evaluated comparing random changes (i.e. typical error of measurement representing the noise) with the smallest worthwhile change expected from a training intervention [22]. The difference between signal and noise defines the sensitivity in detecting systematic variation in training interventions [22]. In this study, the smallest worthwhile change of post-exercise HR measures showed to be not close enough to the typical error of measurement (Table 1). This indicates an unacceptable ability of the post-exercise HR measures to detect small but worthwhile variations at the individual level, likely due to the extremely high intensity of the RSE that is related to the persistent elevation of adrenergic factors and local metabolites during recovery (e.g. H+, lactate, Pi) [41], which impairs the parasympathetic activity [3].

Conclusions

Though RSE seems to be an effective method to improve post-exercise parasympathetic function [6], it seems to be not associated with acceptable levels of signal stability during the recovery period, as already observed for submaximal exercises [18]. This is due to the noise in the measurement, suggesting caution when attempting to assess meaningful changes or differences in the post-exercise HR indices after longitudinal RSE interventions. Indeed, only when alterations in HRR and HRV exceed the typical error can practitioners confidently interpret a meaningful change in parasympathetic function after RSE.

Acknowledgments

The authors wish to thank the participants involved in the present study. We would also like to express our gratitude to Lupo Guiati for his logistical support during the investigation. This study was partly funded by an intramural grant of the Università degli Studi di Milano for the support of research. The funder had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.

References

  1. 1. Bishop D, Girard O, Mendez-Villanueva A. Repeated-sprint ability—part II: recommendations for training. Sports Med. 2011; 41(9):741–56. pmid:21846163
  2. 2. Girard O, Mendez-Villanueva A, Bishop D. Repeated-sprint ability—part I: factors contributing to fatigue. Sports Med. 2011; 41(8):673–94. pmid:21780851
  3. 3. Buchheit M, Laursen PB, Ahmaidi S. Parasympathetic reactivation after repeated sprint exercise. Am J Physiol Heart Circ Physiol. 2007; 293(1):H133–41. pmid:17337589
  4. 4. Nakamura FY, Soares-Caldeira LF, Laursen PB, Polito MD, Leme LC, Buchheit M. Cardiac autonomic responses to repeated shuttle sprints. Int J Sports Med. 2009; 30(11):808–13. pmid:19685413
  5. 5. Niewiadomski W, Gasiorowska A, Krauss B, Mroz A, Cybulski G. Suppression of heart rate variability after supramaximal exertion. Clin Physiol Funct Imaging. 2007; 27(5):309–19. pmid:17697028
  6. 6. Vernillo G, Agnello L, Barbuti A, Di Meco S, Lombardi G, Merati G, et al. Postexercise autonomic function after repeated-sprints training. Eur J App Physiol. 2015; 115(11):2445–55.
  7. 7. Buchheit M. Monitoring training status with HR measures: do all roads lead to Rome? Front Physiol. 2014; 27(5):73.
  8. 8. Lamberts RP, Swart J, Capostagno B, Noakes TD, Lambert MI. Heart rate recovery as a guide to monitor fatigue and predict changes in performance parameters. Scand J Med Sci Sports. 2010; 20(3):449–57. pmid:19558377
  9. 9. Aubert AE, Seps B, Beckers F. Heart rate variability in athletes. Sports Med. 2003; 33(12):889–919. pmid:12974657
  10. 10. Bonato M, Agnello L, Galasso L, Montaruli A, Roveda E, Merati G, et al. Acute modification of cardiac autonomic function of high-intensity interval training in collegiate male soccer players with different chronotype: a cross-over study. J Sports Sci Med. 2017; 16(2):286–94. pmid:28630583
  11. 11. Le Meur Y, Pichon A, Schaal K, Schmitt L, Louis J, Gueneron J, et al. Evidence of parasympathetic hyperactivity in functionally overreached athletes. Med Sci Sports Exerc. 2013; 45(11):2061–71. pmid:24136138
  12. 12. Buchheit M, Papelier Y, Laursen PB, Ahmaidi S. Noninvasive assessment of cardiac parasympathetic function: postexercise heart rate recovery or heart rate variability? Am J Physiol Heart Circ Physiol. 2007; 293(1):H8–10. pmid:17384128
  13. 13. Buchheit M, Gindre C. Cardiac parasympathetic regulation: respective associations with cardiorespiratory fitness and training load. Am J Physiol Heart Circ Physiol. 2006; 291(1):H451–8. pmid:16501030
  14. 14. Millar PJ, Rakobowchuk M, McCartney N, MacDonald MJ. Heart rate variability and nonlinear analysis of heart rate dynamics following single and multiple Wingate bouts. Appl Physiol Nutr Metab. 2009; 34(5):875–83. pmid:19935849
  15. 15. Hopkins WG. Measures of reliability in sports medicine and science. Sports Med. 2000; 30(1):1–15. pmid:10907753
  16. 16. Sandercock G. Normative values, reliability and sample size estimates in heart rate variability. Clin Sci. 2007; 113(3):129–30. pmid:17451377
  17. 17. Bosquet L, Gamelin FX, Berthoin S. Reliability of postexercise heart rate recovery. Int J Sports Med. 2008; 29(3):238–43. pmid:17614018
  18. 18. Al Haddad H, Laursen PB, Chollet D, Ahmaidi S, Buchheit M. Reliability of resting and postexercise heart rate measures. Int J Sports Med. 2011; 32(8):598–605. pmid:21574126
  19. 19. Dupuy O, Mekary S, Berryman N, Bherer L, Audiffren M, Bosquet L. Reliability of heart rate measures used to assess post-exercise parasympathetic reactivation. Clin Physiol Funct Imaging. 2012; 32(4):296–304. pmid:22681607
  20. 20. Arduini A, Gomez-Cabrera MC, Romagnoli M. Reliability of different models to assess heart rate recovery after submaximal bicycle exercise. J Sci Med Sport. 2011; 14(4):352–7. pmid:21450521
  21. 21. Pinna GD, Maestri R, Torunski A, Danilowicz-Szymanowicz L, Szwoch M, La Rovere MT, et al. Heart rate variability measures: a fresh look at reliability. Clin Sci. 2007; 113(3):131–40. pmid:17381425
  22. 22. Hopkins WG, Marshall SW, Batterham AM, Hanin J. Progressive statistics for studies in sports medicine and exercise science. Med Sci Sports Exerc. 2009; 41(1):3–13. pmid:19092709
  23. 23. Impellizzeri FM, Marcora SM. Test validation in sport physiology: lessons learned from clinimetrics. Int J Sports Physiol Perform. 2009; 4(2):269–77. pmid:19567929
  24. 24. Vianna LC, Oliveira RB, Silva BM, Ricardo DR, Araujo CG. Water intake accelerates post-exercise cardiac vagal reactivation in humans. Eur J App Physiol. 2008; 102(3):283–8.
  25. 25. Ferrari Bravo D, Impellizzeri FM, Rampinini E, Castagna C, Bishop D, Wisloff U. Sprint vs. interval training in football. Int J Sports Med. 2008; 29(8):668–74. pmid:18080951
  26. 26. Haugen T, Buchheit M. Sprint running performance monitoring: methodological and practical considerations. Sports Med. 2016; 46(5):641–56. pmid:26660758
  27. 27. Cronin JB, Templeton RL. Timing light height affects sprint times. J Strength Cond Res. 2008; 22(1):318–20. pmid:18296992
  28. 28. Glaister M, Howatson G, Pattison JR, McInnes G. The reliability and validity of fatigue measures during multiple-sprint work: an issue revisited. J Strength Cond Res. 2008; 22(5):1597–601. pmid:18714226
  29. 29. Gamelin FX, Berthoin S, Bosquet L. Validity of the polar S810 heart rate monitor to measure R-R intervals at rest. Med Sci Sports Exerc. 2006; 38(5):887–93. pmid:16672842
  30. 30. Takahashi T, Okada A, Saitoh T, Hayano J, Miyamoto Y. Difference in human cardiovascular response between upright and supine recovery from upright cycle exercise. Eur J App Physiol. 2000; 81(3):233–9.
  31. 31. Kiviniemi AM, Hautala AJ, Kinnunen H, Tulppo MP. Endurance training guided individually by daily heart rate variability measurements. Eur J App Physiol. 2007; 101(6):743–51.
  32. 32. Bloomfield DM, Magnano A, Bigger JT Jr., Rivadeneira H, Parides M, Steinman RC. Comparison of spontaneous vs. metronome-guided breathing on assessment of vagal modulation using RR variability. Am J Physiol Heart Circ Physiol. 2001; 280(3):H1145–50. pmid:11179058
  33. 33. Kobayashi H. Does paced breathing improve the reproducibility of heart rate variability measurements? J Physiol Anthropol. 2009; 28(5):225–30. pmid:19823004
  34. 34. Sandercock GR, Bromley PD, Brodie DA. The reliability of short-term measurements of heart rate variability. Int J Cardiol. 2005; 103(3):238–47. pmid:16098384
  35. 35. Mietus JE, Peng CK, Henry I, Goldsmith RL, Goldberger AL. The pNNx files: re-examining a widely used heart rate variability measure. Heart. 2002; 88(4):378–80. pmid:12231596
  36. 36. Tarvainen MP, Niskanen JP, Lipponen JA, Ranta-Aho PO, Karjalainen PA. Kubios HRV—heart rate variability analysis software. Comput Methods Programs Biomed. 2014; 113(1):210–20. pmid:24054542
  37. 37. Weir JP. Quantifying test-retest reliability using the intraclass correlation coefficient and the SEM. J Strength Cond Res. 2005; 19(1):231–40. pmid:15705040
  38. 38. Atkinson G, Nevill AM. Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine. Sports Med. 1998; 26(4):217–38. pmid:9820922
  39. 39. Buchheit M, Simpson MB, Al Haddad H, Bourdon PC, Mendez-Villanueva A. Monitoring changes in physical performance with heart rate measures in young soccer players. Eur J Appl Physiol. 2012; 112(2):711–23. pmid:21656232
  40. 40. Stuckey MI, Tordi N, Mourot L, Gurr LJ, Rakobowchuk M, Millar PJ, et al. Autonomic recovery following sprint interval exercise. Scand J Med Sci Sports. 2012; 22(6):756–63. pmid:21535187
  41. 41. Glaister M. Multiple sprint work: physiological responses, mechanisms of fatigue and the influence of aerobic fitness. Sports Med. 2005; 35(9):757–77. pmid:16138786