Abstract

This study investigates an off-line solid phase extraction (SPE) for improving the sensitivity in the capillary electrophoretic (CE) analysis of four cephalosporins. Two sorbents—LiChrolut-C18 and Oasis HLB—were used in a SPE process to detect cephalosporins in natural waters (tap, river and hospital sewage) and their performances were compared. By using Oasis HLB sorbent higher recoveries for river water were obtained (94–107% when 500 mL of sample were analyzed). The off-line SPE–CZE method was validated for river water with good detection limits (3 μg L−1) and the linearity ranged between 5 and 200 μg L−1.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1

Similar content being viewed by others

References

  1. Petrovic M, Hernando MD, Díaz-Cruz MS, Barceló D (2005) J Chromatogr A 1067:1–14

    Article  CAS  Google Scholar 

  2. Turiel E, Bordin G, Rodríguez AR (2005) J Sep Sci 28:257–267

    Article  CAS  Google Scholar 

  3. Lindberg R, Wennberg P, Johansson M, Tysklind M, Andersson B (2005) Environ Sci Technol 39:3421–3429

    Article  CAS  Google Scholar 

  4. Benito-Peña E, Partal-Rodera AI, León-González ME, Moreno-Bondi MC (2006) Anal Chim Acta 556:415–422

    Article  Google Scholar 

  5. Lindberg R, Jarnheimer PA, Olsen B, Johansson M, Tysklind M (2004) Chemosphere 57:1479–1488

    Article  CAS  Google Scholar 

  6. Cha JM, Yang S, Carlson KH (2006) J Chromatogr A 1115:46–57

    Article  CAS  Google Scholar 

  7. Hirsch R, Ternes T, Haberer K, Kratz KL (1999) Sci Total Environ 225:109–118

    Article  CAS  Google Scholar 

  8. Pajchel G, Tyski S (2000) J Chromatogr A 895:27–31

    Article  CAS  Google Scholar 

  9. Li YM, Zhu Y, Vanderghinste D, Schepdael AV, Roets E, Hoogmartens J (1999) Electrophoresis 20:127–131

    Article  Google Scholar 

  10. Mrestani Y, Janich M, Rüttinger HH, Neubert RHH (2000) J Chromatogr A 873:237–246

    Article  CAS  Google Scholar 

  11. Mrestani Y, El-Mokdad N, Rüttinger HH, Neubert R (1998) Electrophoresis 19:2895–2899

    Article  CAS  Google Scholar 

  12. García-Ruiz C, Marina ML (2006) Electrophoresis 27:266–282

    Article  Google Scholar 

  13. Lin CE, Chen HW, Lin EC, Lin KS, Huang HC (2000) J Chromatogr A 879:197–210

    Article  CAS  Google Scholar 

  14. Puig P, Borrull F, Calull M, Aguilar C (2005) Chromatographia 62:603–610

    Article  CAS  Google Scholar 

  15. Suzuki H, Nagata M, Ohzono S, Fujimoto C (2005) Chromatographia 61:333–337

    Article  CAS  Google Scholar 

  16. Reverte S, Borrull F, Pocurull E, Marce RM (2003) J Chromatogr A 1010:225–232

    Article  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to M. Calull.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Puig, P., Borrull, F., Aguilar, C. et al. CE Analysis of Cephalosporins in Environmental Waters. Chroma 65, 501–504 (2007). https://doi.org/10.1365/s10337-007-0181-2

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1365/s10337-007-0181-2

Keywords

Navigation