Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group

Correction method for the influence of environmental factors on laser-induced breakdown spectroscopy

Not Accessible

Your library or personal account may give you access

Abstract

Environmental factors include sample temperature, ambient gas composition, and pressure, which have a significant impact on the accuracy and stability of the analysis results of laser-induced breakdown spectroscopy (LIBS). In this study, a method for simultaneously correcting the influence of several environmental factors is proposed. When the calibration and application environment are different, only one sample is needed to be measured in the application environment to correct the influence of environmental factors, so that the calibration model can obtain good analytical accuracy in this environment. When using one to four samples to correct the influence of environmental factors, the application of the calibration models constructed under solid-state conditions at atmosphere pressure to analyze seven elements in molten alloys in vacuum demonstrated the average root mean square error of prediction (RMSEP) of 0.57%, 0.51%, 0.41%, and 0.30% respectively. The accuracy of using only one sample to correct the influence of environmental factors was much higher than using two samples to establish calibration models in the application environment. This proved the effectiveness of the developed method for reducing the difficulty and cost of calibration in the metallurgical processes.

© 2021 Optical Society of America

Full Article  |  PDF Article
More Like This
Self-absorption correction method for one-point calibration laser-induced breakdown spectroscopy

Zhenlin Hu, Junfei Nie, Zhiyong Ouyang, Deng Zhang, Yuanchao Liu, Yanwu Chu, and Lianbo Guo
Opt. Lett. 48(1) 1-4 (2023)

Accuracy improvement of single-sample calibration laser-induced breakdown spectroscopy with self-absorption correction

Fan Deng, Zhenlin Hu, Deng Zhang, Feng Chen, Xuechen Niu, Junfei Nie, Qingdong Zeng, and Lianbo Guo
Opt. Express 30(6) 9256-9268 (2022)

Homogeneous-material-based calibration method for correcting laser-induced breakdown spectroscopy measurement-error bias in the case of dust pollution

Yang Zhao, Lei Zhang, Wangbao Yin, Jiajia Hou, Zhe Wang, Zongyu Hou, Weiguang Ma, Lei Dong, Guangye Yang, Liantuan Xiao, and Suotang Jia
Appl. Opt. 56(35) 9644-9648 (2017)

Data Availability

Data underlying the results presented in this Letter are not publicly available at this time but may be obtained from the authors upon reasonable request.

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Figures (2)

You do not have subscription access to this journal. Figure files are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Tables (5)

You do not have subscription access to this journal. Article tables are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Equations (10)

You do not have subscription access to this journal. Equations are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All Rights Reserved