A Simple Calculation for Obtaining Shunt Fractions of Portosystemic Shunts
Makoto WASHIZUShido TORISUYogo KONDONashiku SHIMIZUTsukimi WASHIZUNaoyuki TAKEMURAGen KINOSHITA
Author information
JOURNAL FREE ACCESS

2004 Volume 66 Issue 4 Pages 449-451

Details
Abstract

Since the isotopes can not be utilized for veterinary patients in Japan, the authors developed a simple calculation formula of shunt fraction of portosystemic shunt based on the hepatic circulation model. The shunt fraction can be calculated utilizing only 2 portal pressure measurements of pre-shunt ligation and temporary or permanent shunt ligation. The calculated shunt fraction can obtained pre-ligation and post-ligation either temporally or permanent complete shunt ligation: complete ligation group of PSS (n=59) had 48.2 ± 16.9% of shunt fractions, whereas the partial ligation group (n=48) had 71.6 ± 10.7% of shunt fractions.

Content from these authors
© 2004 by the Japanese Society of Veterinary Science

この記事はクリエイティブ・コモンズ [表示 - 非営利 - 改変禁止 4.0 国際]ライセンスの下に提供されています。
https://creativecommons.org/licenses/by-nc-nd/4.0/deed.ja