Skip to main content

Assessment of pulmonary vascular anatomy: comparing augmented reality by holograms versus standard CT images/reconstructions using surgical findings as reference standard

Abstract

Background

We compared computed tomography (CT) images and holograms (HG) to assess the number of arteries of the lung lobes undergoing lobectomy and assessed easiness in interpretation by radiologists and thoracic surgeons with both techniques.

Methods

Patients scheduled for lobectomy for lung cancer were prospectively included and underwent CT for staging. A patient-specific three-dimensional model was generated and visualized in an augmented reality setting. One radiologist and one thoracic surgeon evaluated CT images and holograms to count lobar arteries, having as reference standard the number of arteries recorded at surgery. The easiness of vessel identification was graded according to a Likert scale. Wilcoxon signed-rank test and κ statistics were used.

Results

Fifty-two patients were prospectively included. The two doctors detected the same number of arteries in 44/52 images (85%) and in 51/52 holograms (98%). The mean difference between the number of artery branches detected by surgery and CT images was 0.31 ± 0.98, whereas it was 0.09 ± 0.37 between surgery and HGs (p = 0.433). In particular, the mean difference in the number of arteries detected in the upper lobes was 0.67 ± 1.08 between surgery and CT images and 0.17 ± 0.46 between surgery and holograms (p = 0.029). Both radiologist and surgeon showed a higher agreement for holograms (κ = 0.99) than for CT (κ = 0.81) and found holograms easier to evaluate than CTs (p < 0.001).

Conclusions

Augmented reality by holograms is an effective tool for preoperative vascular anatomy assessment of lungs, especially when evaluating the upper lobes, more prone to anatomical variations.

Trial registration

ClinicalTrials.gov, NCT04227444

Relevance statement

Preoperative evaluation of the lung lobe arteries through augmented reality may help the thoracic surgeons to carefully plan a lobectomy, thus contributing to optimize patients’ outcomes.

Key points

• Preoperative assessment of the lung arteries may help surgical planning.

• Lung artery detection by augmented reality was more accurate than that by CT images, particularly for the upper lobes.

• The assessment of the lung arterial vessels was easier by using holograms than CT images.

Graphical Abstract

Background

In thoracic surgery, careful preoperative planning, focusing on the pulmonary vascular anatomy of the lobe candidate to lobectomy, is essential in order to reduce the risk of vascular injury, to increase the self-confidence of the operator, to reduce the duration of the procedure, and to optimize the outcome of the procedure [1]. In fact, a 20–30% variation rate from standard vascular anatomy has been reported, thus making lobar resection difficult [2, 3]. This can be even more important when anatomical resection is performed by minimally invasive techniques (video-assisted or robotic-assisted) which currently represent the most common approaches to early-stage lung cancer resections and require careful knowledge of pulmonary vascular anatomy [4]. A proper preoperative assessment of pulmonary artery branch number, location, take-off, and relation with closer anatomical structures results in safer, faster, and overall better vascular dissection during the procedure [5]. Although lobar vein dissection and closure is also an essential step of lung lobectomy, its relevant lower variation rate in number and course usually makes this step of the operation less demanding and more comfortable for the operator [6].

Computed tomography (CT) is a standard of care in the preoperative assessment of lung cancer, not only in terms of oncologic staging but also for pulmonary anatomy evaluation before planning resection [7]. In recent years, augmented reality, including holography, has emerged as a possible further tool for medical imaging with potentially excellent applications in thoracic surgical procedures. The development of holograms (HG) in the 1960s is due to the research of Gabor et al. [8] and was then helped in its growth by many others when light sources became available with the invention of the laser [9, 10]. The enhancement of the real world by using computer-generated data is currently defined as augmented reality (AR) [11]. Thanks to constant advancements obtained by head-mounted displays, the use of holograms (HGs) and AR in clinical medicine and in medical education has become more easily accessible, frequent, and successful.

The primary objective of this prospective study was to compare the performance of standard preoperative CT images and HGs to assess the number of arteries of a lung lobe undergoing resection for curative resection of primary lung cancer. The secondary objective was to compare the perceived easiness in data interpretation by radiologists and thoracic surgeons by using standard CT images and HG.

Methods

This single-center prospective cohort study was conducted at the European Institute of Oncology (Milan, IT). The local Institutional Review Board approved this study (IRB R1033/19-IEO1088). Written informed consent was obtained from each patient. This trial was registered at ClinicalTrials.gov—Identifier: NCT04227444. Enrollment started on March 1, 2020, and continued to reach the number of patients suggested by the sample size calculation.

Patient selection

The inclusion criteria were planned anatomical lobar resection for lung cancer, signed and dated informed consent indicating that the patient has been informed of all pertinent aspects of the study, and willingness and ability to comply with study procedures. The exclusion criteria were age younger than 18 years, intraoperative findings leading the surgeon not to perform standard lobectomy, patients unable to provide informed consent, and CT scan performed without administration of iodinated contrast medium.

CT protocol

The CT examinations were performed either on a 64-slice Siemens Somatom go.Top (Siemens Healthineers, Forchheim, Germany) or on a 64-slice GE MSTC Optima 660 (General Electric Healthcare, Milwaukee, WI, USA), with the following main acquisition parameters, respectively for the two machines: kV 80–120 and 100–140; mA according to automatic exposure control; pitch of 0.8 and 0.516; tube rotation time 0.33 s and 0.5 s; slice thickness 1–3 mm and 1.25–2.5 mm; and collimation 64 × 0.6 and 64 × 0.625.

All scans extended in a cranio-caudal direction in the portal venous phase, 70–90 s after the intravenous administration of Ultravist 370 (Bayer Healthcare, Berlin, Germany) or Visipaque 320 (GE Healthcare, Milan, IT). Quantity and injection rate were adapted to the weight of the patient and to the CT protocol clinically indicated, respectively. All the CT images were archived in digital format and comprised multiplanar reconstructions (in the sagittal and coronal view), as well as maximum intensity projections.

Augmented reality (HGs) generation

A prototypal software developed by Artiness srl (Milan, Italy) was used to visualize and process the CT scans, generate patient-specific three-dimensional (3D) models (from acquisitions reconstructed with slice thickness 1.25 mm [kernel lung] or 2.5 mm [kernel standard]), and visualize them in a mixed reality (MxR) setting. The CT images were processed using a non-local means filtering [12] to remove noise.

The desktop component of the prototypal software allowed the generation of the 3D models of the lungs, airways, pulmonary arteries, pulmonary veins, and tumor. The lung models were generated using a semiautomated algorithm based on the computation of their isosurface using a marching cubes algorithm and a set of morphological operations. The isovalue was computed automatically, while a set of points on the large airways needs to be manually selected in order to remove them from the model. The airways, pulmonary arteries, and veins were segmented by selecting a series of points along their axes, setting the minimum and maximum HU thresholds to restrict segmentation and generating a deformable model using a level-set formulation. The number of iterations and a set of parameters controlling the level-set propagation were optimized for tubular and branching structures. The tumor isosurface was identified using a marching cubes algorithm.

The MxR component allowed the visualization and analysis of the 3D models and the CT images from which they were generated, alongside a set of tools to interact with them. The 3D models can be translated, rotated, scaled, and selectively shown or hidden. An interactive plane could be used to temporarily hide portions of the 3D models and allow an unencumbered visualization of the features of interest. The MxR component runs on a Microsoft HoloLens 2.0 device (Microsoft Corp., Redmond, WA, USA) (Fig. 1; Additional file 1: Video S1)

Fig. 1
figure 1

Example of holographic reconstruction of the vascular and bronchial structures of the lungs and of a lung tumor (light blue: bronchial tree; red: arteries; blue: veins; yellow: tumor)

Surgery

Patients underwent the planned surgical resection. The operating team reported the exact number of artery branches of the resected lobe. The surgeons who performed the operating procedure were never involved in the evaluation of CT images and HGs, to prevent any source of potential bias.

Image analysis

One radiologist with 20 years of experience in thoracic CT reading (S.R.) and one thoracic surgeon with 22 years of experience in thoracic surgery (F.P.) analyzed the pseudonymized CT images in one or more of the available planes and reconstructions, until a satisfying evaluation was reached and reported the number of arteries for the lobe resected. In a separate reading session, they analyzed the coded HG by using Microsoft Hololens and reported the number of arteries for the lobe resected. The two reading sessions were performed with a time-lapse of at least 7 days, to ensure a sufficient washout time avoiding comparator review bias. The easiness in artery branch identification on CT images and on HGs was graded by the radiologist and by the thoracic surgeon according to a Likert scale, where identification of the lobar arteries could be “very difficult,” “difficult,” “neutral,” “easy,” or “very easy.”

Statistical analysis

The sample size in this study was calculated based on the endpoint “number of artery branches of the lobe slated for resection.” The study’s null hypothesis (H0) assumed that CTs and HGs would have similar accuracy, meaning both methods would consistently identify the same number of artery branches as observed during surgery. The alternative hypothesis (H1) assumed that the accuracy differs between the two methods. For the purpose of sample size calculation, we specifically hypothesized a scenario where HGs would outperform CT images by detecting an average of 0.5 more actual artery branches. Considering a 5% type I error, a sample size of 50 patients was determined to be necessary to achieve an 80% statistical power in refuting H0, using a one-sample, two-sided Wilcoxon signed-rank test. Power estimations were based on simulations, with the number of actual artery branches assumed to be distributed according to a zero-truncated Poisson distribution with a mean of 3.6 [1].

Continuous data were reported as median and ranges or interquartile ranges (IQR) or as mean and standard deviation (SD) according to non-normal or normal/near-normal distribution, respectively. Categorical data were reported as counts and percentages.

For the primary analysis, we calculated for each patient i:

  1. i.

    The difference between the number of artery branches identified by the operating team (NSURG,i) and the mean number of artery branches identified after a CT scan by the radiologist and the surgeon (NCT,i), as DIFFCT,i = NSURG,i − NCT,i (the greater the difference, the lower the accuracy of the CT)

  2. ii.

    The difference between the number of artery branches identified by the operating team (NSURG,i) and the mean number of artery branches identified after HG by the radiologist and the surgeon (NHG,i), as DIFFHG,i = NSURG,i − NHG,i (the greater the difference, the lower the accuracy of the HG)

  3. iii.

    The difference between the two above-defined differences, as DIFFi = DIFFCT,i − DIFFHG,i = NHG,i − NCT,i

Wilcoxon’s signed-rank test was used to test the primary null hypothesis. It was also used to test if the difference between CT and HG accuracy in detecting the number of artery branches was the same between the two site groups (upper lobes versus middle/lower lobes). If a high agreement was found between the radiologist’s and the surgeon’s evaluation, an average between the two evaluations was considered for further analyses evaluating the accuracy of CTs and HGs in identifying the number of artery branches.

Linear weighted κ statistic was used to evaluate the agreement among the number of artery branches detected by the radiologist and the thoracic surgeon.

To evaluate if reading HGs was easier than reading CT, we performed two Wilcoxon signed-rank sum test, the first comparing “CT by radiologist” with “HG by radiologist” evaluations and the second one comparing “CT by surgeon” with “HG by surgeon” evaluations.

p-values lower than 0.05 were considered statistically significant.

All analyses were performed with the statistical software SAS 9.4 (SAS Institute, Cary, NC, USA).

Results

Enrollment started on March 1, 2020, and ended on March 1, 2022. Sixty-one patients were initially enrolled in this study; six patients were excluded because anatomical lobar resection was not performed because of intraoperative findings; three were excluded because of allergy to iodinated contrast medium, which did not allow generating the HGs. Eventually, 52 patients were included in this study. As shown in Table 1, 28 were females (54%) and 24 were males (46%), with a median age of 67 years (range 38–82); the median number of days between CT scan and surgical procedure was 36 (range 1–113). Right upper lobectomy was performed in 15 of 52 patients (29%), middle lobectomy in 4 patients (8%), right lower lobectomy in 12 patients (23%), left upper lobectomy in 15 patients (29%) (Fig. 2), and left lower lobectomy in 6 patients (12%). Fourteen patients (27%) were operated on by robotic-assisted thoracic surgery, 13 patients (25%) were operated on by video-assisted thoracic surgery, 23 patients (44%) were approached by lateral thoracotomy, and 2 patients (4%) were operated via postero-lateral thoracotomy.

Table 1 Patient characteristics (n = 52)
Fig. 2
figure 2

Coronal maximum intensity projection reconstruction of the contrast-enhanced computed tomography scan (a), containing a white box indicating where the pulmonary vessels were specifically evaluated, and HG of the pulmonary vascular anatomy (b) in a patient candidate to right upper lobe lobectomy for lung cancer (green lesion). The radiologist and surgeon evaluation where concordant with the reference standard (surgery) in indicating a single artery for the upper lobe (white arrow in a and b)

The radiologist and the thoracic surgeon detected the same number of artery branches of the resected lobe in 44 cases (85%) for CT scans and 51 cases (98%) for HGs. A high agreement was observed for both CT scans (weighted κ = 0.81, 95% confidence interval 0.68–0.93), and HGs (weighted κ = 0.99, 95% confidence interval 0.96–1.00) (Table 2).

Table 2 Agreement between radiologist and surgeon evaluations, using computed tomography (panel a) and holograms (panel b)

A high agreement was found between the radiologist’s and the surgeon’s evaluation (Additional file 2: Figs. S1 and S2, Tables S1 and S2).

The mean difference between the number of artery branches detected by surgery (reference standard) and on CT images was 0.31 ± 0.98, whereas it was 0.09 ± 0.37 between surgery and HGs. The p-value for the statistical test comparing these two mean differences was 0.433 (Additional file 2: Fig. S3). The mean difference between the number of artery branches detected by surgery and HG was 0.17 ± 0.46 for the upper lobes and -0.02 ± 0.11 for the middle and lower lobes, whereas the mean difference between surgery and CT images was 0.67 ± 1.08 for the upper lobes and -0.18 ± 0.55 for the middle and lower lobes (Additional file 2: Fig. S4).

As shown in Table 3, the difference between CT image and HG accuracy in detecting the number of artery branches in the upper lobes (difference 0.50 ± 1.06) was significantly different from the difference between CT and HG accuracy in the middle and lower lobes (-0.16 ± 0.52) (p = 0.024).

Table 3 Differences between the number of artery branches detected with surgery (reference standard) and with computed tomography and holograms, divided by site (upper versus middle/lower lobes)

Perceived easiness in data interpretation by radiologist and thoracic surgeon using CT images and HGs is reported in Fig. 3, showing that both the radiologist and the thoracic surgeon found it easier to evaluate cases with HG than with CT images. Furthermore, the CT evaluation was sometimes very difficult to read for both clinicians (no very easy cases), whereas the HG evaluation was never very difficult for either clinician, and in some cases, it was very easy. Tables 4 and 5 show data on difficulty in identifying arteries by the radiologist and the surgeon. Figure 4 presents a comparison of the ease with which HGs and CT scans are interpreted by the surgeon (panel a) and the radiologist (panel b), demonstrating a significant advantage (p < 0.001) in the simplicity of interpreting HGs over CT scans for both clinicians.

Fig. 3
figure 3

Difficulty/easiness in identifying the arteries: computed tomography (CT) versus holograms (HG) (n = 52)

Table 4 Difficulty/easiness in identifying the lung arteries by the radiologist: computed tomography (CT) versus holograms (n = 52)
Table 5 Difficulty/easiness in identifying the lung arteries by the thoracic surgeon: computed tomography (CT) versus holograms (n = 52)
Fig. 4
figure 4

Difficulty in identifying the arteries by radiologist (a) and by surgeon (b): computed tomography (CT) versus holograms (HG) (n = 52). Each line represents the paired evaluation of difficulty in identifying the artery branches in a single patient by using CT images or HG. Lines that appear darker and thicker indicate a higher frequency of patients receiving that specific combined evaluation by the radiologist or by the surgeon

Discussion

In our prospective cohort, the evaluation of the lung arteries in patients undergoing pulmonary lobectomy was well performed by CT scans and HGs, but HGs outperformed the CT evaluation for upper lobes, where a higher number of vascular variability is present. Furthermore, evaluation of HG is judged to be easier than that of CT, especially for the evaluation done by the surgeon, who is the final user of this data.

Intraoperative dissection, isolation, and closure of artery branches of a lung lobe to be resected represent one of the most challenging steps during standard pulmonary lobectomy. This is mainly due to a high variability rate of vascular pulmonary anatomy and to some anatomical conditions, such as incomplete fissures, bulky tumors, and lymph node distortion of vascular structures which may result in difficult vascular management [2]. In this scenario, a thorough knowledge of the anatomical distribution of pulmonary vessels may help the less expert surgeon to plan the single steps of the surgery well before entering the operating room, and the more expert surgeon to better plan the duration of the surgery. This is even more true in minimally invasive approaches like video-assisted and robot-assisted thoracic surgery, where tactile feedback and manual palpation is not available, although better intraoperative vision might balance this limit [4, 5]. An accurate vascular anatomy knowledge before embarking on pulmonary resection results in a safer, faster, and more confident dissection, reducing potential vascular injuries and optimizing procedure duration and results.

Multidetector CT is the standard imaging technique for preoperative anatomy evaluation, as it allows the evaluation of standard anatomy as well as prognostication in many different settings [13, 14]. In fact, thanks to the progress of the technique in terms of x-ray tubes, detectors, and reconstruction methods, it allows a detailed vision of the anatomy with a short examination time (within a few seconds) and with progressively lower doses of radiation to the patient [15]. The rapidity of the acquisition allows significant motion artifact reduction, while the use of a contrast medium enhances imaging features and resolution [16]. However, the standard axial CT images may be difficult to be translated into a 3D visualization of the surgical field by the operating surgeon. For this reason, postprocessing methods have been developed to create anatomical models closer to the surgical anatomy view. For example, maximum intensity projection is a reconstruction technique increasing the contrast of high attenuation structures, such as lung vessels, maximizing their definition on a two-dimensional plane, while volume rendering is an automatic reconstruction tool based on CT attenuation values of color, brightness, and opacity, generating a three-dimensional image of anatomical structures presenting different densities [17, 18]. In this series, the evaluation of CT images comprised the standard axial acquisitions, the multiplanar reconstructions, and the maximum intensity projections, with no distinction of the contribution given by each one, in order to reproduce a real-world evaluation, where all the series available can be checked and visualized to reach the scope of seeing the arterial branches.

In the last few years, augmented reality has emerged as a promising alternative to standard imaging techniques for preoperative planning in several different districts [18,19,20,21,22,23]. Spatial recognition, eye tracking, and hand tracking are the most intriguing and encouraging properties of augmented reality. Spatial recognition relies on the ability of full recognition of the world around the operator; eye tracking consists of the capacity to recognize what the operator is seeing, projecting HGs in the visual field of the operator by light rays; hand tracking allows the operator to move, rotate, stretch, touch, and globally interact with the HG by using his/her hands and fingers. Therefore, HGs enhance the clinical scenario by using immersive cinematic photo-real projections, thus providing the operator with a digital overlay of clinical reality [24].

In this study, the use of HGs offered the possibility to interact with a 3D reconstruction of the lungs, where the different anatomical structures could be included or removed according to preference. This allowed us to have a complete and exhaustive view of the lungs and their vessels in one view, which could also be stretched, enlarged, or rotated to look for more precise details. Our findings disclosed that the lobe in which the tumor is located influences HG assessment of the pulmonary arteries to a lesser extent, whereas CT images are less effective than HGs in the assessment of the lung arteries of the upper lobes. According to this result, from a surgical point of view, HGs can significantly contribute to preoperative vascular anatomy assessment, particularly in the case of upper lobectomies that are the most difficult procedures in terms of vascular isolation and dissection.

When the augmented reality technology is available and affordable in the future, we would advise its use in all cases. However, this is still not the case, with costs and time required being the current main disadvantages of the use of this technology. For this reason, given the success in the evaluation of the vessels of the upper lobes, where anatomical variants are more frequent and surgical resection is more challenging, we would advise a thorough evaluation of vascular anatomy of the lung upper lobes before a planned lobectomy by using HGs. This technology may also be of help for teaching less experienced thoracic surgeons before a planned surgery, thus offering a new opportunity for a didactic innovation towards personalized surgery.

Moreover, perceived easiness in data interpretation was higher with HGs for both the radiologist and the thoracic surgeon. In fact, in order to look for vascular details and to follow the individual vascular branches on CT images, it is necessary to scroll up and down the axial images many times, with the intrinsic risk of losing the vessel under evaluation and the need to start again. In this study, HGs proved to be a tool easy to manage, because the offered 3D image is immediate, clear, and easy to interpret, as demonstrated by the evaluation by both the surgeon and the radiologist.

Of note, the HG processing from the standard preoperative CT scan does not need additional radiation dose, different contrast media administration, or redundant procedures for the patients.

This study has some limitations. First, the final sample size (n = 52) was relatively small for definite conclusions to be drawn; nonetheless, our preliminary analysis to define the sample size according to the primary endpoint indicated that this would have been a proper sample. Our results are encouraging towards a wider evaluation of the impact of the use of HGs in preoperative planning for candidates for lung resections. Second, the CT acquisitions were performed in the venous phase, as for usual staging at our institution, although we are aware that a CT acquisition in the arterial phase would have resulted in better visualization of the arterial branches in CT images. However, CT for staging of lung cancer usually also includes the abdomen, and in this clinical situation, a single delayed acquisition for thoracic and abdominal contrast-enhanced CT is associated with low contrast-related perivenous artifact and affords better visualization of the lymph nodes, while acceptable vascular and hepatic contrast enhancement is maintained [25]. Since at our institution, the standard CT protocol for lung cancer staging includes only a venous phase of the thorax, we decided to do this first study with possibly nonoptimal images, then given interesting results, we might plan a subsequent study with the use of a modified CT protocol including a single arterial pass on the thorax.

In conclusion, our study suggests that HGs are an effective tool for lung vascular anatomy assessment, showing higher diagnostic consistency across different lobes, when compared to standard preoperative staging CT scans. Its major contribution was observed in the detection of branch arteries of upper lobes, where greater anatomical variability maximizes its benefit. Additionally, the HGs were perceived to be easier to interpret than CT images.

Availability of data and materials

The datasets used and/or analyzed during the current study are available from the corresponding author upon reasonable request.

Abbreviations

3D:

Three-dimensional

AR:

Augmented reality

HG:

Hologram

IQR:

Interquartile range

MxR:

Mixed reality

References

  1. Smelt JLC, Suri T, Valencia O et al (2019) Operative planning in thoracic surgery: a pilot study comparing imaging techniques and three-dimensional printing. Ann Thorac Surg 107:401–406. https://doi.org/10.1016/j.athoracsur.2018.08.052

    Article  PubMed  Google Scholar 

  2. Fourdrain A, De Dominicis F, Blanchard C et al (2018) Three-dimensional CT angiography of anatomic variations in the pulmonary arterial tree. Surg Radiol Anat 40:45–53. https://doi.org/10.1007/s00276-017-1914-z

    Article  PubMed  Google Scholar 

  3. Cory R, Valentine E (1959) Varying patterns of the lobar branches of the pulmonary artery a study of 524 lungs and lobes seen at operation on 426 patients. Thorax 14:267–280. https://doi.org/10.1136/thx.14.4.267

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  4. Salfity H, Tong BC (2020) VATS and minimally invasive resection in early-stage NSCLC. Semin Respir Crit Care Med 41:335–345. https://doi.org/10.1055/s-0039-3401991

    Article  PubMed  Google Scholar 

  5. Hagiwara M, Shimada Y, Kato Y et al (2014) High-quality 3-dimensional image simulation for pulmonary lobectomy and segmentectomy: results of preoperative assessment of pulmonary vessels and short-term surgical outcomes in consecutive patients undergoing video-assisted thoracic surgery. Eur J Cardiothorac Surg 46:e120-6. https://doi.org/10.1093/ejcts/ezu375

    Article  PubMed  Google Scholar 

  6. Fukuhara K, Akashi A, Nakane S, Tomita E (2008) Preoperative assessment of the pulmonary artery by three-dimensional computed tomography before video-assisted thoracic surgery lobectomy. Eur J Cardiothorac Surg 34:875–877. https://doi.org/10.1016/j.ejcts.2008.07.014

    Article  PubMed  Google Scholar 

  7. Zheng W, Zhang M, Wu W, Zhang H, Zhang X (2022) Three-dimensional CT angiography facilitates uniportal thoracoscopic anatomic lung resection for pulmonary sequestration: a retrospective cohort study. J Cardiothorac Surg 17:218. https://doi.org/10.1186/s13019-022-01975-8

    Article  PubMed  PubMed Central  Google Scholar 

  8. Gabor D, Kock WE, Stroke GW (1971) Holography. Science 173:11–23. https://doi.org/10.1126/science.173.3991.11

    Article  CAS  PubMed  Google Scholar 

  9. Jung C, Wolff G, Wernly B et al (2022) Virtual and augmented reality in cardiovascular care: state-of-the-art and future perspectives. JACC Cardiovasc Imaging 15:519–532. https://doi.org/10.1016/j.jcmg.2021.08.017

    Article  PubMed  Google Scholar 

  10. Kumar RP, Pelanis E, Bugge R et al (2020) Use of mixed reality for surgery planning: assessment and development workflow. J Biomed Inform 112S:100077. https://doi.org/10.1016/j.yjbinx.2020.100077

    Article  PubMed  Google Scholar 

  11. Dolega-Dolegowski D, Proniewska K, Dolega-Dolegowska M et al (2022) Application of holography and augmented reality based technology to visualize the internal structure of the dental root - a proof of concept. Head Face Med 18:12. https://doi.org/10.1186/s13005-022-00307-4

    Article  PubMed  PubMed Central  Google Scholar 

  12. Cuomo S, De Michele P, Piccialli F (2014) 3D data denoising via nonlocal means filter by using parallel GPU strategies. Comput Math Methods Med 2014:52386. https://doi.org/10.1155/2014/523862

    Article  Google Scholar 

  13. Botta F, Raimondi S, Rinaldi L et al (2020) Association of a CT-based clinical and radiomics score of non-small cell lung cancer (NSCLC) with lymph node status and overall survival. Cancers 12:1432. https://doi.org/10.3390/cancers12061432

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  14. Rizzo SM, Kalra MK, Schmidt B et al (2005) CT images of abdomen and pelvis: effect of nonlinear three-dimensional optimized reconstruction algorithm on image quality and lesion characteristics. Radiology 237:309–315. https://doi.org/10.1148/radiol.2371041879

    Article  PubMed  Google Scholar 

  15. Kalra MK, Rizzo S, Maher MM et al (2005) Chest CT performed with z-axis modulation: scanning protocol and radiation dose. Radiology 237:303–308. https://doi.org/10.1148/radiol.2371041227

    Article  PubMed  Google Scholar 

  16. Hernandez AM, Abbey CK, Ghazi P, Burkett G, Boone JM (2020) Effects of kV, filtration, dose, and object size on soft tissue and iodine contrast in dedicated breast CT. Med Phys 47:2869–2880. https://doi.org/10.1002/mp.14159

    Article  CAS  PubMed  Google Scholar 

  17. Jung J, Kim K, Ahn M et al (2011) Detection of pulmonary embolism using 64-slice multidetector-row computed tomography: accuracy and reproducibility on different image reconstruction parameters. Acta Radiol 52:417–421. https://doi.org/10.1258/ar.2011.100217

    Article  PubMed  Google Scholar 

  18. Boiselle P, Reynolds K, Ernst A (2002) Multiplanar and three-dimensional imaging of the central airways with multidetector CT. AJR Am J Roentgenol 179:301–308. https://doi.org/10.2214/ajr.179.2.1790301

    Article  PubMed  Google Scholar 

  19. Ong CW, Tan MCJ, Lam M, Koh VTC (2021) Applications of extended reality in ophthalmology: systematic review. J Med Internet Res 23:e24152. https://doi.org/10.2196/24152

    Article  PubMed  PubMed Central  Google Scholar 

  20. Mangano FG, Admakin O, Lerner H, Mangano C (2023) Artificial intelligence and augmented reality for guided implant surgery planning: a proof of concept. J Dent 133:104485. https://doi.org/10.1016/j.jdent.2023.104485

    Article  PubMed  Google Scholar 

  21. Ryu S, Kitagawa T, Goto K, et al. (2022) Intraoperative holographic guidance using virtual reality and mixed reality technology during laparoscopic colorectal cancer surgery. Anticancer Res. 42:4849-4856. https://doi.org/10.21873/anticanres.15990

  22. Tokunaga T, Sugimoto M, Saito Y et al (2022) Intraoperative holographic image-guided surgery in a transanal approach for rectal cancer. Langenbecks Arch Surg 407:2579–2584. https://doi.org/10.1007/s00423-022-02607-4

    Article  PubMed  Google Scholar 

  23. Chessa M, Van De Bruaene A, Farooqi K et al (2022) A three-dimensional printing, holograms, computational modelling, and artificial intelligence for adult congenital heart disease care: an exciting future. Eur Heart J 43:2672–2684. https://doi.org/10.1093/eurheartj/ehac266

    Article  PubMed  Google Scholar 

  24. Ramesh PV, Joshua T, Ray P et al (2022) Holographic elysium of a 4D ophthalmic anatomical and pathological metaverse with extended reality/mixed reality. Indian J Ophthalmol 70:3116–3121. https://doi.org/10.4103/ijo.IJO_120_22

    Article  PubMed  PubMed Central  Google Scholar 

  25. García-Garrigós E, Arenas-Jiménez JJ, Sánchez-Payá J (2018) Best protocol for combined contrast-enhanced thoracic and abdominal CT for lung cancer: a single-institution randomized crossover clinical trial. AJR Am J Roentgenol 210:1226–1234. https://doi.org/10.2214/AJR.17.19185

    Article  PubMed  Google Scholar 

Download references

Acknowledgements

The English text was revised by Susan West. No large language models (LLMs) were used in this manuscript. The authors acknowledge the support of the APC central fund of the University of Milan.

Funding

This study has received funding from the Grant “Progetto di Eccellenza” from MIUR (Ministero dell’ Istruzione, Università e Ricerca) won by the Department of Oncology and Hemato-oncology of the University of Milan, Italy.

Author information

Authors and Affiliations

Authors

Contributions

FP and SMR wrote the paper. CR, MC, GP, and LS contributed to the interpretation of the imaging examinations and performed the surgery. VB and SF performed the statistical analysis. SP and OP provided their expertise in creating the holograms and performing the augmented reality setting. All authors read and approved the final manuscript.

Corresponding author

Correspondence to Stefania Maria Rita Rizzo.

Ethics declarations

Ethics approval and consent to participate

The local Institutional Review Board approved this study (IRB R1033/19-IEO1088). Written informed consent was obtained from each patient. This trial was registered at ClinicalTrials.gov—Identifier: NCT04227444.

Consent for publication

Not applicable

Competing interests

SMRR is a member of the Scientific Editorial Board for European Radiology Experimental (Section: Imaging biomarkers, radiomics, radiogenomics, and imaging biobanks). They have not participated in the selection or review processes for this article. The authors of this manuscript also declare relationships with the following companies: SP and OP work for Artiness SRL, Viale Cassala 57, 20143, Milan, Italy. The other authors declare that they have no competing interests.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Supplementary Information

Additional file 1: Video S1. Supplementary video.

Additional file 2:

 Fig. S1. Differences between the number of artery branches detected with surgery (gold standard) and with both computed tomography and holograms by radiologist (Panel A) and by surgeon (Panel B) (N = 52). Fig. S2. Differences between the number of artery branches detected with surgery (gold standard) and with both computed tomography and holograms by radiologist (Panel A and B) and by surgeon (Panel C and D), among patients with “Upper” (Panel A and C) and “Middle/Lower” (Panel B and D) site. Fig. S3. Differences between the number of artery branches detected by surgery (reference standard) and by computed tomography and holograms (N = 52). Fig. S4. Differences between the number of artery branches detected by surgery (reference standard) and by computed tomography and holograms, between patients with “Upper” (Panel A) and“Middle/Lower” (Panel B) site. Table S1. Differences between the number of artery branches detected with surgery (gold standard) and with both computed tomography and holograms by radiologist and by surgeon, divided by site (Upper versus Middle/Lower). Table S2. Supplementary Table 2. Differences between the number of artery branches detected with surgery (reference standard) and with CT and holograms (HG), by radiologist and by surgeon.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Petrella, F., Rizzo, S.M.R., Rampinelli, C. et al. Assessment of pulmonary vascular anatomy: comparing augmented reality by holograms versus standard CT images/reconstructions using surgical findings as reference standard. Eur Radiol Exp 8, 57 (2024). https://doi.org/10.1186/s41747-024-00458-w

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s41747-024-00458-w

Keywords