Skip to main content

Correction to: Comparison of automatic and manual chamber methods for measuring soil respiration in a temperate broad-leaved forest

The Original Article was published on 07 December 2018

Correction to: Journal of Ecology and Environment (2018) 42:32

https://doi.org/10.1186/s41610-018-0093-0

Following publication of the original article (Lee, 2018), it was reported that a mismatch occurred between the online HTML article and the PDF version. In the PDF version of the article, text was missing on page 3 between “Rs was calculated from the rate of increase in CO2 concentration measured per unit of time (Eq. (1)):” and the equation “Rs (mg CO2 m-2 h-1) = a · ρ · V · S-1” (2)

The text from the beginning of page 3 should read as follows:

… AOCC system. Also, AOCC can minimize the artificial disturbance caused by the measurement because there is little access of the measurer around the measuring point. A detailed description of this type of system can be found in Suh et al. (2006) and Eom et al. (2018). Rs was calculated from the rate of increase in CO2 concentration measured per unit of time (Eq. (1)):

$$ \mathrm{Rs}\ \left(\mathrm{mg}\ {\mathrm{CO}}_2\ {\mathrm{m}}^{-2}\ {\mathrm{h}}^{-1}\right)=a\cdotp \rho \cdotp L\cdotp {A}^{-1} $$
(1)

where a is the increasing rate of the CO2 (ppm min− 1) in the closed chamber system, ρ is the density of CO2, L is the total volume of the closed chamber system (m3) included in chamber, tube, IRGA, pump etc., and A is the surface area in the chamber.

In the MCM, the CO2 concentration was measured using a closed chamber cap of approximately 15 cm high that was installed with a CO2 sensor (GMP343, Vaisala, Finland) at the top inner section. When the chamber cap was installed on the collar top, the CO2 concentration in the closed space between the ground and the chamber cap increased with time (Lee, 2018). In the MCM, the Rs was calculated using the following Eq. (2):

$$ \mathrm{Rs}\ \left(\mathrm{mg}\ {\mathrm{CO}}_2\ {\mathrm{m}}^{-2}\ {\mathrm{h}}^{-1}\right)=a\cdotp \rho \cdotp V\cdotp {S}^{-1} $$
(2)

The original article (Lee, 2018) has been updated.

Reference

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Jae-Seok Lee.

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Lee, JS. Correction to: Comparison of automatic and manual chamber methods for measuring soil respiration in a temperate broad-leaved forest. j ecology environ 43, 1 (2019). https://doi.org/10.1186/s41610-018-0100-5

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s41610-018-0100-5