Skip to main content

Development of chromatographic methods to determine multivitamins formulation depending on their solubility and polarity: comparative study using three greenness assessment tools

Abstract

High performance liquid chromatography is one of the techniques of choice for the separation and quantitative determination of drugs in mixture form. Ipriflavone, ascorbic acid, pyridoxine, vitamin D3, and lysine are formulated together as an adjuvant combination in osteoporosis. In this work, we developed and validated two complementary high performance liquid chromatographic methods to determine the five compounds in their pharmaceutical dosage form. The first method (method A) was capable of determining ipriflavone, ascorbic acid, pyridoxine, and vitamin D3 in their bulk and combined pharmaceutical formulation. The method is based on Liquid Chromatographic separation with UV detection at 254 nm using Agilent Eclipse XDB-C18 column with a mobile phase consisting of 25 mM ammonium acetate buffer (pH 4.2): methanol in gradient mode. Due to the high polarity of lysine, it was difficult to achieve satisfactory retention on reversed phase columns. So, we separated it on a strong cation exchange column (Exsil 100 SCX) without derivatization with a mobile phase consisting of 10 mM sodium dihydrogen phosphate and 200 mM sodium chloride (pH 6) with UV detection at 210 nm (method B). Validation of the proposed methods was performed according to ICH guidelines Q2(R1). The proposed methods proved to be valid for selective analysis of the stated drugs in their bulk and combined pharmaceutical formulation. Greenness assessment of the developed methods was evaluated using three assessment tools: ESA, GAPI and the most recently developed tool AGREE, showing a satisfactory comprehensive guide of the greenness of the developed methods.

Peer Review reports

Introduction

Ascorbic acid (vitamin C) (Asc) (Fig. 1A) plays a chief role as a redox cofactor and catalyst in a broad range of biochemical reactions and processes [1]. Pyridoxine hydrochloride (Py) (Fig. 1B) is 4,5-bis(hydroxymethyl)-2-methylpyridin-3-ol hydrochloride. Among the B vitamins, pyridoxine hydrochloride (vitamin B6) has unique role in the metabolism of lipids, proteins, and carbohydrates. Vitamin D3(Vit D3), (Fig. 1C) is (5Z,7E) -(3S)-9,10-seco-5,7,10(19)-cholestatrien-3-ol, it acts to maintain calcium and phosphorus homeostasis which is required for many biological processes. Ipriflavone (Ip) (Fig. 1D) is 7-isopropoxy-3-phenyl-4H-chromen-4-one [2], it is used for the prevention and treatment of postmenopausal osteoporosis. Ipriflavone is effective in the reduction of bone turnover by inhibiting bone resorption and stimulating bone formation [3]. Lysine hydrochloride (Lys) (Fig. 1E) is an essential amino acid used as building unit for proteins in the body.

Fig. 1
figure 1

Chemical structures of active drug substances

The studied active drug substances are formulated together in a capsule form that is used as an adjuvant therapy in case of loss of bone density.

Several methods including HPLC with UV, FLD and/or mass detection [4,5,6,7,8,9,10,11,12,13,14,15,16,17,18,19,20], micellar electrokinetic chromatographic (MEKC) [21], spectrofluorimetric [22] were reported for the determination of these compounds in different multivitamins combinations in different matrices.

Ipriflavone was also determined by several techniques, in tablets by square-wave adsorptive cathodic stripping (SW-AdCS) voltammetry and LC- UV methods [23], in plasma by Liquid chromatography with mass detection [24, 25], with its synthetic impurities by HPLC–PDA [26], HPLC -UV study of its pharmacokinetics and distribution in rabbits and human beings [27,28,29,30] and also in rat plasma, urine and tissue homogenate [31].

Lysine was analysed by several HPLC methods either singly or in presence of other amino acids using an aqueous mobile phase pumped at low flow rate to achieve satisfactory retention on reversed phase column [32] or by derivatization with ortho-phtaldehyde and 9-Fluorenylmethyl chloroformate [33], 4-dinitro-fluorobenzene (FDNB) [34, 35], or by HILIC column [36].

The concept of green analytical chemistry (GAC) has been emerging recently as a part of the global consideration and concern towards minimizing the hazardous impacts on the environment and health. It aims mainly at developing eco-friendly, less occupationally hazardous analytical methods based on the 12 principles of GAC proposed by Anastas and Warner [37, 38]. Since the evolvement of the GAC principles, many assessment tools and metrics were proposed to evaluate the greenness of the developed analytical methods. These greenness evaluation metric systems vary in the degree of embodiment of more or less of the GAC principles.

Our literature survey revealed that no method was reported to resolve the mixture of the five components or to determine them in their combined dosage form. So, the aim of this work was to develop and validate a HPLC method that can separate Ipriflavone, ascorbic acid, pyridoxine HCl, vitamin D3 and lysine HCl in a reasonable run time to be used for the quality control of their bulk powders and pharmaceutical dosage form. We also aimed to investigate the compliance of the developed methods with the GAC principles using three greenness assessment tools to give a comprehensive overview of the greenness of the proposed methods.

Experimental

Materials


a) Pure samples


Ipriflavone (99.64%), ascorbic acid (100.17%), pyridoxine hydrochloride (99.8%), vitamin D3 oil 40,000,000 IU/gm and lysine hydrochloride (99.66%) were kindly obtained from Eldebeiky Pharma (DBK), Egypt.


b) Market samples


Ultracalce® capsules labeled to contain ipriflavone 25 mg, ascorbic acid 30 mg, pyridoxine hydrochloride 1 mg, vitamin D3 0.005 mg and lysine hydrochloride 25 mg per capsule manufactured by AL-Debeiky Pharma Co. were purchased from the local market.


c) Chemicals and reagents


HPLC grade methanol (Scharlau, Spain), ammonium acetate (Qualikems, India), glacial acetic acid (Merck, Germany), sodium dihydrogen phosphate, sodium chloride and phosphoric acid (Merck, Germany) and Merck Milli Q Ultrapure Water were used in chromatographic analyses. Twenty-five millimole ammonium acetate buffer was prepared by dissolving 1.93 g of ammonium acetate in one litre of water (pH was adjusted to 4.2 with glacial acetic acid). The mobile phase for lysine hydrochloride elution was prepared by dissolving 1.56 gm sodium dihydrogen phosphate and 11.9 gm sodium chloride in one litre water (pH was adjusted to 6 with orthophosphoric acid).

Instrumentation

Dionex ultimate 3000 Standard LC System equipped with a quaternary pump, standard manual injector with a 20 µL loop, multiple wavelength detector with Data acquisition performed on chromeleon 7.2 software was used as chromatographic system.

Sartorius electric balance (Germany). Hamilton microsyringe 100 µL capacity, Sonicator (R. Espinar S.L,Spain) and Digital PH meter (HANNA, USA) were also used.

Chromatographic conditions

Method A

For Ipriflavone, ascorbic acid, pyridoxine hydrochloride, vitamin D3, separation was performed on a reversed phase column, Agilent Zorbax Eclipse XDB-C18 (250 X 4.6 mm i.d, 5 µm particle size), with a mobile phase consisting of solution A (acetate buffer) and solution B methanol for elution of ipriflavone, ascorbic acid, pyridoxine hydrochloride and vitamin D3 in gradient mode with as follows, initially 97% of Solution A (0–3 min), (97–0%) solution A (3–5 min), 0% solution A (5–9 min) then (0–97%) solution A (9–11 min) with three minutes equilibration at the initial conditions between runs. UV detection was performed at 254 nm. The flow rate was 1 mL/min.

Method B

For lysine hydrochloride, separation was performed on Dr.Maisch Exsil 100 SCX (150 X 4.6 mm i.d, 5 µm particle size) column using a mobile phase consisting of 10 mM sodium dihydrogen phosphate and 200 mM sodium chloride (pH 6) pumped at flow rate 1 mL/min and detection was performed at 210 nm.

In both chromatographic methods the system was operated at ambient temperature. All samples were filtered through a 0.45 µm syringe filter, and  L were injected by the aid of Hamilton microsyringe. The columns used were conditioned for at least 30 min or until stable baseline before injection.

Preparation of standard stock and working solutions

Standard stock solutions were prepared in water for Asc, Py and Lys and in methanol for Ip and Vit D3 by accurately weighing 50 mg of each into five 50 mL volumetric flasks (final concentration 1000 µg/mL for all). Further dilutions of standard stock solutions were done into five 100 mL volumetric flasks with the same solvents to prepare working standard solutions of 100 µg/mL for Asc, Py, Ip, Vit D3, and 200 µg/mL for Lys.

Procedures

Construction of calibration curve

Dilutions for calibration curves' construction were prepared by transferring aliquots of Asc, Py, Lys, Ip and Vit D3 working standard solutions equivalent to 25–800 µg, 75–900 µg, 400–2000 µg, 100–1000 µg, 10–600 µg, respectively into series of 10 mL volumetric flasks. The volume was completed to the mark with water in case of Asc, Py and Lys and with methanol in case of Ip and Vit D3 to reach final concentration ranges of 2.5–80 µg/mL for Asc, 7.5–90 µg/mL for Py, 40–200 µg /mL for Lys, 10–100 µg/mL for Ip, and 1–60 µg/mL for Vit D3. Each solution was injected in triplicates and chromatographed under the previously mentioned chromatographic conditions. The chromatograms were recorded, the peak areas were determined and the calibration curve relating peak areas to the corresponding concentrations for each compound was constructed.

Application to pharmaceutical formulations

The content of ten capsules were mixed well, the average content weight of one single capsule was weighed and transferred into two 25 mL volumetric flasks. The content of the first flask was dissolved in 15 mL water while the content of the second flask was dissolved in 15 mL methanol by sonication in ultrasonic water bath for 10 min. The volume was completed to the mark with the same solvents in each flask. From the stock solution in water, 1.25 mL was diluted into 75 mL volumetric flask (Asc preparation), 1.25 mL into 5 mL volumetric flask (Py preparation), and 0.4 mL into 10 mL volumetric flask (Lys preparation). In all the three preparations the volume was completed to the mark with water to get final nominal concentrations 20 µg/mL, 10 µg/mL, 40 µg/mL for Asc, Py, Lys, respectively.

From the stock solution in methanol, for Ip sample solution 0.5 mL was diluted into 25 mL volumetric flask and the volume was completed to the mark with methanol (final nominal concentration for Ip 20 µg/mL). Vit D3 was determined by weighing one capsule fill weight into 5 mL volumetric flask, dissolving in methanol with sonication in ultrasonic water bath for 5 min (final nominal concentration 1 µg/mL). Standard addition technique [40] was done to confirm results due to the very low concentration of Vit D3 in capsule (5 µg/capsule).

Results and discussion

Method optimization

Optimization of mobile phase

We made many attempts to separate the five analytes together in one single run using many different mobile phases' compositions like water and acetonitrile in different proportions, buffers including TEAC (triethyl amine: acetic acid mixture), phosphate buffer with changing pH values and compositions with different organic modifiers but in most cases lysine was not observed and no complete satisfactory separation and resolution between the other four compounds (Asc, Py, IP, and Vit D3) were achieved. Finally, acetate buffer with methanol combination was tried in gradient mode due to the good solubility of ammonium acetate in methanol where we achieved good separation and resolution between the four compounds in reasonable run time but still lysine was not detected. Two injections were done one for the two analytes dissolved in water (Asc, Py) and second run for the two analytes dissolved in methanol (IP and Vit D3) (Fig. 2).

Fig. 2
figure 2

a HPLC chromatogram for separation of Asc and Py. b HPLC chromatogram for separation of IP and Vit D3

In all trials on different reversed phase columns (C8, C18), it was difficult to achieve satisfactory retention for lysine due to its high polarity. In an attempt to comply with GAC principles, we avoided its determination by the tedious derivatization approach to reduce the use of reagents, so we considered another mode of HPLC separation depending on lysine polarity and its basic nature on a strong cation exchange column. Strong cation exchange columns with aliphatic sulfonic acid groups carry negative charges in all pH ranges, therefore can bind basic analytes and this mode is widely used in the separation of a range of molecules from amino acids to large biomolecules where elution is achieved by increasing ionic strength of the mobile phase with high salt concentration. Under these conditions, we obtained good retention and separation for Lys (Fig. 3). Figures 4 and 5 show blank injections.

Fig. 3
figure 3

HPLC chromatogram for separation of Lys using the cation exchange column

Fig. 4
figure 4

Blank injection chromatogram for method A

Fig. 5
figure 5

Blank injection chromatogram for method B

Optimization of gradient mode

Due to the polar nature of Asc and Py, they were separated under high aqueous conditions especially for Asc to achieve satisfactory retention on reversed phase column then the organic modifier was linearly increased to elute the highly hydrophobic Vit D3 and IP with good resolution.

Selection of buffer pH

For method A, buffer pH is critical for Asc and Py peak shape and elution. Both have two pka values; Asc is a diprotic acid while Py is a basic compound so optimizing the pH to 4.2 after trials of many buffers with many different pH values provided slightly acidic medium for Asc and Py to achieve good retention and resolution. Upon increasing pH value, elution of three peaks was observed probably representing two ionization states of Py. Decreasing pH < 4 caused peak distortion of Py (appearance of peak shoulder). Buffer pH has no effect on the elution of IP and Vit D3 as they have to be eluted under high organic conditions due to their hydrophobic nature and retention on reversed phase columns.

For method B, pH has no effect on the SCX stationary phase as it carries negative charge over the whole pH range, but the pH is critical for the analyte to be bound to the stationary phase. pH 6 was found to be optimum for the elution of Lys. At this pH value Lys is positively charged achieving good retention to the negatively charged stationary phase. Then elution with replacement by salts from the stationary phase gave good peak shape and satisfactory retention relative to the standard reversed phase mode of separation.

Selection of detection wavelength

For method A, the maximum wavelengths were 265 nm for Asc, 220 nm for Py, 250 nm for IP, 212 and 265 nm for Vit D3, so we chose 254 nm as a center point to allow the determination of the four analytes at single wavelength with reasonable sensitivity for the four compounds.

For method B, Lys lacks chromophores, so it should be determined at short wavelengths to achieve good sensitivity so 210 nm was found to be optimum for its determination with good sensitivity.

Selection of type of solvents

We chose water to dissolve Asc, Py and Lys as they are all freely soluble in it. Also, methanol could not be used under almost 100% aqueous mobile phase at the start of the run to avoid peak shape deforming due to solvent elution strength exceeding that of the mobile phase. Methanol was chosen to dissolve IP and Vit D3 as both are freely soluble in it. Selection of solvent is especially crucial for Vit D3 as it is present in very low dose in capsule (5 µg/cap) so solvent in which it is freely soluble is mandatory to extract Vit D3 completely from capsule for accurate determination.

Method validation

The proposed method was validated according to the ICH guidelines [39, 40].

System suitability

The system suitability parameters are presented in (Table 1) including capacity factor which is a measure of the location of the peak of interest with respect to the void volume and column efficiency expressed as number of theoretical plates (N) which represents the number of peaks that can be eluted per unit run-time of the chromatogram [40]. All parameters were satisfactory and met the recommended acceptance criteria.

Table 1 System suitability testing parameters for the developed HPLC methods

Linearity

The linearity of the developed method was investigated, and the linear regression data for the calibration curves showed good linearity with correlation coefficient (r) > 0.999.

Range

The specified ranges derived from linearity studies were over the following concentrations: 2.5–80 µg/mL, 7.5–90 µg/mL, 10–100 µg/mL, 1–60 µg/mL, 20–200 µg/mL for Asc, Py, Ip, Vit D3, Lys, respectively with respect to peak area (Table 2).

Table 2 Validation parameters of the proposed HPLC methods for the determination of Ipriflavone, Ascorbic acid, Pyridoxine, Vitamin D3 and Lysine

Accuracy

Accuracy of the proposed methods was studied by standard addition technique on true solution and on pharmaceutical formulation and evaluating recovery results. Results presented in Tables 2, 6, 7, 8, 9, 10 indicate good accuracy of the proposed methods (Recovery at each level ± RSD: 100.00% ± 2).

Precision

We analysed homogenous samples of capsules over different days to obtain inter-days (intermediate precision, n = 3 for each concentration) and within the same day to obtain intra-day precision (repeatability, n = 3 for each concentration), then the RSDs % values were calculated. The developed method was proved to be precise as the RSD% was < 2% (Table 2).

Robustness

Robustness of the method was checked by investigating the effect of small deliberate changes in the experimental conditions on the system suitability parameters. We evaluated the change in system suitability parameters upon elution of analytes with mobile phase of minor change in pH value (4.2 ± 0.2) and different column brands. The RT values of the four analytes and resolution between them using the mentioned pH range did not change, while changing the column brand was accompanied by slight decrease or increase of RT of the eluted peaks also minor increase and decrease in resolution between them. For method B for separation of Lys, robustness was evaluated upon change in mobile phase pH and flow rate with satisfactory corresponding change in system suitability parameters (Tables 3, 4, 5).

Table 3 Robustness study for the developed HPLC method for the determination of Ipriflavone, Ascorbic acid, Pyridoxine and Vitamin D3 upon change in pH
Table 4 Robustness study for the developed HPLC method for the determination of Ipriflavone, Ascorbic acid, Pyridoxine and Vitamin D3 upon change in column brand
Table 5 Robustness study for the developed HPLC method for the determination Lysine upon change in pH value and flow rate of the mobile phase

Specificity

The specificity of the proposed methods was examined for the presence of interference from excipients or sample matrix by applying the standard addition on the dosage form to which known amounts of each analyte have been added to give good recovery results confirming no interference from other excipients or analytes in capsule matrix [40] (Tables 6, 7, 8, 9, 10).

Table 6 Evaluation of the accuracy of the proposed HPLC method (method A) for the determination of Ascorbic acid by standard addition on Ultracalce®capsules
Table 7 Evaluation of the accuracy of the proposed HPLC method (method A) for the determination of Pyridoxine hydrochloride by standard addition on Ultracalce®capsules
Table 8 Evaluation of the accuracy of the proposed HPLC method (method A) for the determination of Ipriflavone by standard addition on Ultracalce®capsules
Table 9 Evaluation of the accuracy of the proposed HPLC method (method A) for the determination of Vitamin D3 by standard addition on Ultracalce®capsules
Table 10 Evaluation of the accuracy of the proposed HPLC method (method B) for the determination of Lysine hydrochloride by standard addition on Ultracalce®capsules

Analysis of marketed formulation (Ultrcacalce®capsules)

The proposed HPLC methods were successfully applied for the quantitative assay of the five compounds in its pharmaceutical formulation with good percentage recoveries (Tables 2, 6, 7, 8, 9, 10). Chromatograms for pharmaceutical formulation preparations are shown in Fig. 6

Fig. 6
figure 6

chromatograms of different preparations of Ultracalce® capsule

Greenness assessment

In our attempt to stick to the global commitment to imply greenness in any developed procedures, we assessed the greenness of the proposed methods before proceeding for method validation and application. Three metrics were used for greenness assessment namely Analytical Eco-Scale Assessment (ESA) [41, 42], Green Analytical Procedure Index (GAPI) [43], and the last and the newest one: AGREE—Analytical GREEnness metric [44]. Investigation of the methods' greenness by Eco-scale metric shows that both methods have excellent greenness profiles.

GAPI also can give more thorough coverage of the whole analytical procedure starting from sample collection to waste treatment. From the pictograms of the developed methods A and B, it can be observed that the red segments are due to the macroextration scale of pharmaceutical products and the use of methanol representing non-green solvent in the case of method A and the associated health and safety hazards also the slightly large waste generated from HPLC methods. The same data can be reflected in another way in the twelve sections of AGREE pictogram with additional details about sample amount, process automation, and analysis throughput and operator safety. Red parts of the pictograms in the developed methods are due to the manual processing, methanol as a non-green solvent in method A but generally, the two methods can be considered eco-accepted. Results in Tables 11, 12 prove that the proposed methods are eco-friendly.

Table 11 Penalty points for greenness assessment of the proposed methods by Eco scale tool
Table 12 AGREE/GAPI assessment of the green profile of the evaluated procedures for determination of Ipriflavone, Ascorbic acid, Pyridoxine,Vitamin D3 and Lysine

Conclusion

The proposed HPLC methods provide simple, accurate and reproducible quantitative analysis for the determination of Asc, Py, Ip, Vit D3 and Lys in their pure form and pharmaceutical formulation, without any interference from the excipients so they can be used in routine quality control analysis. Greenness assessment using different assessment tools gives a satisfactory indication of the environmental impact of the developed methods.

Availability of data and materials

The datasets used and/or analysed during the current study are available from the corresponding author on reasonable request.

References

  1. Shad Z, Arsalan A, Bano R, Khan MF, Ahmed I. Physicochemical, biochemical and antioxidant properties of ascorbic acid. J Baqai Med Univ. 2011;14:33–40.

    Google Scholar 

  2. Chemical Entities of Biological Interest (ChEBI) https://www.ebi.ac.uk/chebi/searchId.do?chebiId=CHEBI:31719. Accessed 25 June 2023

  3. Kitatani K, Morii H. [Ipriflavone]. Nihon rinsho. Japan J Clin Med. 1998;56(6):1537–43.

    CAS  Google Scholar 

  4. Giorgi MG, Howland K, Martin C, Bonner AB. A novel HPLC method for the concurrent analysis and quantitation of seven water-soluble vitamins in biological fluids (plasma and urine): a validation study and application. Sci World J. 2012;2012:1–8. https://doi.org/10.1100/2012/359721.

    Article  CAS  Google Scholar 

  5. Vidović S, Stojanović B, Veljković J, Prazić-Arsić L, Roglić G, Manojlović D. Simultaneous determination of some water-soluble vitamins and preservatives in multivitamin syrup by validated stability-indicating high-performance liquid chromatography method. J Chromatogr A. 2008;1202(2):155–62. https://doi.org/10.1016/j.chroma.2008.06.039.

    Article  PubMed  CAS  Google Scholar 

  6. Glinko A, Bozym MJ, Owens ML, Usher KM, Majors RE. Reversed phase HPLC separation of water-soluble vitamins on Agilent ZORBAX Eclipse Plus columns. Agilent application note. Printed in the USA. 2008. Publication number 5989-9313EN.

  7. Joseph S. Analysis of water-soluble vitamins from multivitamin tablets for nutrition labelling. Agilent application note. 2011. Publication number 5990 - 7950EN.

  8. Cho CM, Ko JH, Cheong WJ. Simultaneous determination of water-soluble vitamins excreted in human urine after eating an overdose of vitamin pills by a HPLC method coupled with a solid phase extraction. Talanta. 2000;51:799–806. https://doi.org/10.1016/S0039-9140(00)00283-6.

    Article  PubMed  CAS  Google Scholar 

  9. de Assis R, de Lima Gomes Soares R, Siqueira A, de Rosso V, de Sousa P, Mendes A, de Alencar Costa E, de Góes Carneiro A, Maia C. Determination of water-soluble vitamins and carotenoids in brazilian tropical fruits by high performance liquid chromatography. Heliyon. 2020;6(10):e05307. https://doi.org/10.1016/j.heliyon.2020.e05307.

    Article  PubMed  PubMed Central  CAS  Google Scholar 

  10. Li HB, Chen F. Simultaneous determination of twelve water- and fat-soluble vitamins by high-performance liquid chromatography with diode array detection. Chromatographia. 2001;54:270–3. https://doi.org/10.1007/BF02492256.

    Article  CAS  Google Scholar 

  11. Albala´-Hurtado S, Veciana-Nogue´s MT, Izquierdo-Pulido M, Marine´-Font A. Determination of water-soluble vitamins in infant milk by high-performance liquid chromatography. J Chromatogr A. 1997;778(1–2):247–53. https://doi.org/10.1016/S0021-9673(97)00387-7.

    Article  PubMed  Google Scholar 

  12. Thermo Fisher Scientific, Determination of water- and fat-soluble vitamins by HPLC. Technical note. 72488, 2017. https://assets.thermofisher.com/TFS-Assets/CMD/Technical-Notes/tn-72488-hplc-water-fat-soluble-vitamins-tn72488-en.pdf

  13. Blanco D, Sánchez L, Gutiérrez M. Determination of water-soluble vitamins by liquid chromatography with ordinary and narrow-bore columns. J Liq Chromatogr. 1994;17:1525–39. https://doi.org/10.1080/10826079408013176.

    Article  CAS  Google Scholar 

  14. Rudenko AO, Kartsova LA. Determination of water-soluble vitamin B and vitamin C in combined feed, premixes, and biologically active supplements by reversed phase HPLC. J Anal Chem. 2010;65:71–6. https://doi.org/10.1134/S1061934810010132.

    Article  CAS  Google Scholar 

  15. Gentili A, Caretti F, D’Ascenzo G, Marchese S, Perret D, Di Corcia D, Rocca L. Simultaneous determination of water-soluble vitamins in selected food matrices by liquid chromatography/electrospray ionization tandem mass spectrometry. Rapid Commun Mass Spectrom. 2008;22:2029–43. https://doi.org/10.1002/rcm.3583.

    Article  PubMed  CAS  Google Scholar 

  16. Zafra-Gómez A, Garballo A, Morales J, García-Ayuso L. Simultaneous determination of eight water-soluble vitamins in supplemented foods by liquid chromatography. J Agric Food Chem. 2006;54:4531–6. https://doi.org/10.1021/jf060346e.

    Article  PubMed  CAS  Google Scholar 

  17. Goldschmidt RJ, Wolf WR. Simultaneous determination of water-soluble vitamins in SRM 1849 infant/adult nutritional formula powder by liquid chromatography–isotope dilution mass spectrometry. Anal Bioanal Chem. 2010;397:471–81. https://doi.org/10.1007/s00216-009-3373-9.

    Article  PubMed  CAS  Google Scholar 

  18. Kucukkolbasi S, Bilber O, Ayyildiz H, Kara H. Simultaneous and accurate determination of water- and fat-soluble vitamins in multivitamin tablets by using an RP-HPLC method. Química Nova. 2013;36:1044–51. https://doi.org/10.1590/S0100-40422013000700020.

    Article  CAS  Google Scholar 

  19. Temova Rakuša Ž, Grobin A, Roškar R. A comprehensive approach for the simultaneous analysis of all main water-soluble vitamins in multivitamin preparations by a stability-indicating HPLC-DAD method. Food Chem. 2021;337:127768. https://doi.org/10.1016/j.foodchem.2020.127768.

    Article  PubMed  CAS  Google Scholar 

  20. Chen P, Atkinson R, Wolf WR. Single-laboratory validation of a high-performance liquid chromatographic-diode array detector-fluorescence detector/mass spectrometric method for simultaneous determination of water-soluble vitamins in multivitamin dietary tablets. J AOAC Int. 2009;92:680–7. https://doi.org/10.1093/jaoac/92.2.680.

    Article  PubMed  CAS  Google Scholar 

  21. Olędzka I, Kowalski P, Bączek T, Muszyńska-Furas B, Paradziej-Łukowicz J, Taciak M, Pastuszewska B. Determination of water-soluble vitamins in laboratory animal feeds by micellar electrokinetic chromatography. Anal Lett. 2012;45:689–701. https://doi.org/10.1080/00032719.2011.653903.

    Article  CAS  Google Scholar 

  22. Mohamed A, Mohamed H, Abdel-Latif N, Mohamed M. Spectrofluorimetric determination of some water-soluble vitamins. J AOAC Int. 2011;94:1758–69. https://doi.org/10.5740/jaoacint.9-493.

    Article  PubMed  CAS  Google Scholar 

  23. El-Desoky HS, Beltagi AM, Ghoneim MM. Determination of the anti-osteoporosis drug ipriflavone in pharmaceutical formulation by stripping voltammetric and chromatographic methods. J AOAC Int. 2009;92(3):806–12. https://doi.org/10.1093/jaoac/92.3.806.

    Article  PubMed  CAS  Google Scholar 

  24. Yun C, Ding L, Leng Y, Zhu H, Wen A, Yang L. Determination of ipriflavone in human plasma by LC-MS and its application in a pharmacokinetic study. Biomed Chromatogr. 2011;26:123–8. https://doi.org/10.1002/bmc.1641.

    Article  PubMed  CAS  Google Scholar 

  25. Ji H, Lee H, Kim H, Paek I, Moon Y, Lee H, Kim S, Lee M. Simultaneous determination of ipriflavone and its main metabolites M1 And M5 In human plasma by liquid chromatography with tandem mass spectrometry. Anal Lett. 2005;38:99–110. https://doi.org/10.1081/AL-200043463.

    Article  CAS  Google Scholar 

  26. Sustacha K, Chacón M, Lucero M, Orjales A. Determination of ipriflavone and its synthetic impurities by high-performance liquid chromatography using diode-array detection. J Chromatogr A. 1996;719:245–50. https://doi.org/10.1016/0021-9673(95)00310-X.

    Article  PubMed  CAS  Google Scholar 

  27. Kim SH, Lee JS, Lee MG. Pharmacokinetics and tissue distribution of ipriflavone, an isoflavone derivative, after intravenous administration to rabbits. Biopharm Drug Dispos. 2000;21(4):147–56. https://doi.org/10.1002/1099-081X(200005)21:4.

    Article  PubMed  CAS  Google Scholar 

  28. Xinjun X, Dan Z. Determination of distribution of ipriflavone in rabbits by RP-HPLC. Chin J Pharm Anal. 1997;17:380–1.

    Google Scholar 

  29. Yuqian Z, Chongshu C, Xiaodong S. RP-HPLC simultaneous assay for plasma concentration of ipriflavone and Its metabolite and evaluation for their pharmacokinetics in human being. Chin J Pharm Anal. 1997;17:150–2.

    Google Scholar 

  30. Lévai F, Szatmári I. HPLC method for the concentration determination of ipriflavone and its seven metabolites in human plasma. Toxicol Lett. 1996;88:14. https://doi.org/10.1016/S0378-4274(96)80049-X.

    Article  Google Scholar 

  31. Kim SH, Lee JS, Lee MG. Determination of a isoflavone derivative, ipriflavone, and its metabolites, M1 and M5, in rat plasma, urine, and tissue homogenate by high-performance liquid chromatography. Res Commun Mol Pathol Pharmacol. 1997;98(3):313–24.

    PubMed  CAS  Google Scholar 

  32. Qadir MA, Ahmed M, Hussain WA, Tahir MS. Development and validation of new HPLC method for simultaneous estimation of L-Lysine hydrochloride and L-Carnitine-L-Tartrate in pharmaceutical dosage form. Indian J Pharm Sci. 2015;77:434–8. https://doi.org/10.4103/0250-474x.164772.

    Article  PubMed  PubMed Central  CAS  Google Scholar 

  33. Varzaru I, Untea AE, Martura T, Olteanu M, Panaite TD, Schitea M. Development and validation of an RP-HPLC method for methionine, cystine and lysine separation and determination in corn samples. Revista De Chimie -Bucharest. 2013;64:673–9.

    CAS  Google Scholar 

  34. Castillo G, Sanz M, Serrano M, Hernandez T, Hernandez A. An isocratic high-performance liquid chromatographic method for determining the available lysine in foods. J Chromatogr Sci. 1997;35:423–9. https://doi.org/10.1093/chromsci/35.9.423.

    Article  CAS  Google Scholar 

  35. Yubo L, Huizhu M, Yan′e L, Xiaohong G. HPLC determination of lysine hydrochloride in compound lysine granules. Chin J Pharm Anal. 1999;19:410–2.

    Google Scholar 

  36. Bhandare P, Madhavan P, Rao BM, Someswar rao N. Determination of arginine, lysine and histidine in drug substance and drug product without derivatisation by using HILIC column LC technique. J Chem Pharm Res. 2010;2:580–6.

    CAS  Google Scholar 

  37. Anastas PT, Warner JC. Green chemistry: theory and practice. New York, USA: Oxford University Press; 1998.

    Google Scholar 

  38. Gałuszka A, Migaszewski Z, Namie ́snik J. The 12 principles of green analytical chemistry and the SIGNIFICANCE mnemonic of green analytical practices. TrAC Trends Anal Chem. 2013;50:78–84. https://doi.org/10.1016/j.trac.2013.04.010.

    Article  CAS  Google Scholar 

  39. ICH validation of analytical procedures: methodology, ICH Q2| (R1), in international conference on harmonization (ICH) of technical requirements for the registration of pharmaceuticals for human use.2005. https://database.ich.org/sites/default/files/Q2%28R1%29%20Guideline.pdf. Accessed 26/6/2023

  40. Centre for drug evaluation and research (CDER) reviewer guidance, validation of chromatographic methods. The Analytical Methods Technical Committee of the Chemistry Manufacturing Controls Coordinating Committee (November 1994). https://www.fda.gov/media/75643/download. Accessed 26/6/2023

  41. Aken KV, Strekowski L, Patiny L. Eco scale, semi-quantitative tool to select an organic preparation based on economical and ecological parameters. Beilstein J Org Chem. 2006;2(1):3. https://doi.org/10.1186/1860-5397-2-3.

    Article  PubMed  PubMed Central  CAS  Google Scholar 

  42. Gałuszka A, Migaszewski ZM, Konieczka P, Namieśnik J. Analytical eco-scale for assessing the greenness of analytical procedures. TrAC Trends Anal Chem. 2012;37:61–72. https://doi.org/10.1016/j.trac.2012.03.013.

    Article  CAS  Google Scholar 

  43. Płotka-Wasylka J. A new tool for the evaluation of the analytical procedure: green analytical procedure index. Talanta. 2018;181:204–9. https://doi.org/10.1016/j.talanta.2018.01.013.

    Article  PubMed  CAS  Google Scholar 

  44. Pena-Pereira F, Wojnowski W, Tobiszewski M. Agree—analytical greenness metric approach and software. Anal Chem. 2020;92(14):10076–82. https://doi.org/10.1021/acs.analchem.0c01887.

    Article  PubMed  PubMed Central  CAS  Google Scholar 

Download references

Funding

Open access funding provided by The Science, Technology & Innovation Funding Authority (STDF) in cooperation with The Egyptian Knowledge Bank (EKB).

Author information

Authors and Affiliations

Authors

Contributions

SAG: Raising the idea, Study design, performing practical experiments& data analysis, Writing the first Draft of the manuscript. ESE: Project administration, supervision, Data curation, review and editing the manuscript. EMH and EAA: revising the manuscript, supervision. HEZ: Project administration, Data curation, supervision, review and editing the manuscript and manuscript submission. All authors read and approved the manuscript for publication.

Corresponding author

Correspondence to Hala Elsayed Zaazaa.

Ethics declarations

Ethics approval and consent to participate

The research doesn’t provide any human or animal studies.

Consent for publication

Not applicable.

Competing interests

The authors declare no competing interests.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Galal, S.A.B., Elzanfaly, E.S., Hussien, E.M. et al. Development of chromatographic methods to determine multivitamins formulation depending on their solubility and polarity: comparative study using three greenness assessment tools. BMC Chemistry 18, 20 (2024). https://doi.org/10.1186/s13065-024-01118-1

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13065-024-01118-1

Keywords