Thermal Analysis of Spirally Wound Li/BCX and Li / SOCl2 Cells

and

© 1993 ECS - The Electrochemical Society
, , Citation E. E. Kalu and R. E. White 1993 J. Electrochem. Soc. 140 23 DOI 10.1149/1.2056095

1945-7111/140/1/23

Abstract

A thermal analysis of Li/BCX and high rate cells is presented. The thermal model developed was used to study the effect of ambient temperature of discharge (0–40°C) on Li/BCX cells discharged at the same rate. The model predictions show that ambient temperature of discharge was critical in thermal management of the cell. For forced convection cooled cells, the model predicted that ambient temperature near room temperature (25°C) was required to achieve the lowest maximum temperature rise in the cell. Inclusion of the effects of reaction products to the model predictions showed that a constant composition assumption may be misleading. Heat transfer through the spiral constituted a smaller fraction of the total heat dissipation from the cell. In a comparison of the thermal performance of high rate cell with Li/BCX cell, the model predicted a higher temperature rise in the cell (assuming the temperature rise behaves linearly with discharge current) if both cells were discharged at the same rate.

Export citation and abstract BibTeX RIS