- Split View
-
Views
-
Cite
Cite
JoEtta M. Juenke, Paul I. Brown, Francis M. Urry, Gwendolyn A. McMillin, Drug Monitoring and Toxicology: A Procedure for the Monitoring of Levetiracetam and Zonisamide by HPLC-UV, Journal of Analytical Toxicology, Volume 30, Issue 1, January-February 2006, Pages 27–30, https://doi.org/10.1093/jat/30.1.27
- Share Icon Share
Abstract
This article describes a rapid isocratic high-performance liquid chromatographic (HPLC) method for the simultaneous measurement of the anticonvulsants levetiracetam and zonisamide. Monitoring these drugs is important for detecting potentially toxic concentrations, particularly in patients with renal impairment, but no commercial assays are currently available. Following a liquid-liquid extraction, levetiracetam (5–150 µg/mL) and zonisamide (5–80 µg/mL) are quantitated by HPLC-UV. The assay's limit of quantitation, linearity, imprecision, and accuracy adequately cover the therapeutic range of these drugs. The assay should be attractive to clinical laboratories because the run time for quantification of both drugs is approximately 5 min per sample, and no interferences are currently known.