Abstract
The paper discusses the results of experimental studies of pulsed generators based on a drift diode with a sharp recovery (DSRD) and inductive energy storage of standard and polygonal structures. For the first time the generator of a polygonal design is presented. It is shown that when the generators are working on an active-capacitive load, the rate of voltage rise on it at the generator of a standard construction is lower. The generator of a polygonal design has high characteristics for the rate of increase of voltage and its amplitude. This article will discuss the effect of capacitive load on the rate of voltage rise and the way to increase it.
Export citation and abstract BibTeX RIS
Content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI.