Abstract
Unbalanced radial force is a serious adversity that restricts the working pressure and reduces service life of the single-action vane pump. For revealing and predicting the distribution of radial force on the rotor, a numerical simulation about its transient flow field was performed by using dynamic mesh method with RNG κ ε-turbulent model. The details of transient flow characteristic and pressure fluctuation were obtained, and the radial force and periodic variation can be calculated based on the details. The results show: the radial force has a close relationship with the pressure pulsation; the radial force can be reduced drastically by optimizing the angle of port plate and installing the V-shaped cavity; if the odd number vanes are chosen, it will help reduce the radial force of rotor and optimize the pressure fluctuation effectively.
Export citation and abstract BibTeX RIS
Content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI.