Paper The following article is Open access

Experimental Study on the Influences of Air Flow in an Integral Hydrocarbon Display Cabinet to its Temperature and Energy Performances

, and

Published under licence by IOP Publishing Ltd
, , Citation I N Suamir et al 2019 IOP Conf. Ser.: Mater. Sci. Eng. 494 012017 DOI 10.1088/1757-899X/494/1/012017

1757-899X/494/1/012017

Abstract

This paper presents results on temperature energy performance tests of an integral refrigerated hydrocarbon (HC) display cabinet for retail food applications. Heat from the condensing unit of the cabinet is rejected to both ambient air and water/glycol mixture flowing in a closed water circuit. Air flow in the cabinet loaded with M-packages as test products was studied in order to analyze effects of air flow rate in the cabinet to its temperature and energy performances. The product and air temperatures as well as energy consumption of the cabinet were measured. The tests were conducted in a test chamber at climate class 3. It was found that the HC display cabinet with integral condensing unit was found to provide excellent energy performance with an Energy Efficiency Index below the requirement to qualify for enhanced capital allowances. The refrigeration system of the cabinet could also achieve a COP of 3.15. The study also found that higher air flow rate in the cabinet could make the product temperatures a little bit better, but the energy consumption increased approximately 7% when air flow rate was increased from 1200 m3 h−1 to 1800 m3 h−1. Air flow distribution in the cabinet was necessary to be optimized in order to comply with M0 classification cabinet.

Export citation and abstract BibTeX RIS

Content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI.

Please wait… references are loading.
10.1088/1757-899X/494/1/012017