Abstract
The glassy carbon electrode (GCE) was modified with multiwalled carbon nanotube (MWCNT) and graphene (MWCNT/GCE), (graphene/GCE) to study the electrochemical behaviour of paracetamol using cyclic voltammetric technique at different paracetamol particles size (186μm, 4-9μm, 45nm) in a 10 ml solution of (1M) KCl and (0.1mM) paracetamol at scan rate (0.1 V/s). The results of cyclic voltammogram showed the anodic current peaks of paracetamol increases with decrease particle size. Also, the solubility is enhancement with decreasing particle size. MWCNT/GCE is a good biosensor with high electrochemical sensitivity for paracetamol than graphene/GCE.
Export citation and abstract BibTeX RIS
Content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI.