Experimental evaluation of models for predicting Cherenkov light intensities from short-cooled nuclear fuel assemblies

, , and

Published 20 February 2018 © 2018 IOP Publishing Ltd and Sissa Medialab
, , Citation E. Branger et al 2018 JINST 13 P02022 DOI 10.1088/1748-0221/13/02/P02022

1748-0221/13/02/P02022

Abstract

The Digital Cherenkov Viewing Device (DCVD) is a tool used by nuclear safeguards inspectors to verify irradiated nuclear fuel assemblies in wet storage based on the recording of Cherenkov light produced by the assemblies. One type of verification involves comparing the measured light intensity from an assembly with a predicted intensity, based on assembly declarations. Crucial for such analyses is the performance of the prediction model used, and recently new modelling methods have been introduced to allow for enhanced prediction capabilities by taking the irradiation history into account, and by including the cross-talk radiation from neighbouring assemblies in the predictions. In this work, the performance of three models for Cherenkov-light intensity prediction is evaluated by applying them to a set of short-cooled PWR 17x17 assemblies for which experimental DCVD measurements and operator-declared irradiation data was available; (1) a two-parameter model, based on total burnup and cooling time, previously used by the safeguards inspectors, (2) a newly introduced gamma-spectrum-based model, which incorporates cycle-wise burnup histories, and (3) the latter gamma-spectrum-based model with the addition to account for contributions from neighbouring assemblies. The results show that the two gamma-spectrum-based models provide significantly higher precision for the measured inventory compared to the two-parameter model, lowering the standard deviation between relative measured and predicted intensities from 15.2 % to 8.1 % respectively 7.8 %. The results show some systematic differences between assemblies of different designs (produced by different manufacturers) in spite of their similar PWR 17x17 geometries, and possible ways are discussed to address such differences, which may allow for even higher prediction capabilities. Still, it is concluded that the gamma-spectrum-based models enable confident verification of the fuel assembly inventory at the currently used detection limit for partial defects, being a 30 % discrepancy between measured and predicted intensities, while some false detection occurs with the two-parameter model. The results also indicate that the gamma-spectrum-based prediction methods are accurate enough that the 30 % discrepancy limit could potentially be lowered.

Export citation and abstract BibTeX RIS

10.1088/1748-0221/13/02/P02022