Abstract
A study of the effect of gas pressure in the position resolution of an interacting X or γ-ray photon in a gas medium is performed. The intrinsic position resolution for pure noble gases (Argon and Xenon) and their mixtures with CO2 and CH4 was calculated for several gas pressures (1–10 bar) and for photon energies between 1 and 60 keV, being possible to establish a linear relation between the intrinsic position resolution and the inverse of the gas pressure in the indicated energy range, as intuitively expected. We show how, at high pressures and low photoelectron energies, this intrinsic 1/P scaling is modified due to the diffusion of the primary ionization in the direction perpendicular to the electric field. In order to evaluate the quality of the method here described, a comparison between the available experimental data and microscopic simulations is presented in this work and discussed. In the majority of cases, a good agreement is observed. The conditions to achieve position resolutions down to 10 μm in a realistic detector are shown and discussed.
Export citation and abstract BibTeX RIS
published under the terms of the Creative Commons Attribution 3.0 License by IOP Publishing Ltd and Sissa Medialab srl. Any further distribution of this work must maintain attribution to the author(s) and the published article's title, journal citation and DOI.