Abstract
The results of experimental study on the formation of high-current electron beams using three-electrode system are presented. This system enables to create a diffusive obstructed glow discharge in a pulsed regime with an amplitude of applied voltage up to 25 kV. The influence of such experimental parameters as the pressure of plasma forming gas and the amplitude of applied voltage on the obstructed glow discharge duration was investigated. Both the transverse and the longitudinal structure of formed electron beam was determined.
Export citation and abstract BibTeX RIS