Paper The following article is Open access

Identification of defective Pt structure after neutron and ion irradiation

Published under licence by IOP Publishing Ltd
, , Citation V A Ivchenko 2021 J. Phys.: Conf. Ser. 1799 012012 DOI 10.1088/1742-6596/1799/1/012012

1742-6596/1799/1/012012

Abstract

The adequacy of the effect of radiation exposure of different types on the same material (Pt) has been established. For this purpose, radiation defects of one type were studied using field ion microscopy (FIM). The structure of defects was studied on an atomically clean surface and in the near-surface volume of platinum after bombardment with neutrons and ion beams (E > 0.1 MeV and E = 30 keV, respectively). It is shown that the interaction of fast neutrons (E > 0, 1 MeV, F = 6.7 • 1021 m−2, F = 3.5 • 1022 m−2) with platinum leads to certain radiation damage in the volume. The same defects are observed when irradiated with Ar+ ion beams (E = 30 keV, F = 6.7 • 1020 m−2). The latter were found at a depth of about 1.5-2 nm from the irradiated surface. Thus, analog modeling of neutron and ion irradiation with a substance was performed.

Export citation and abstract BibTeX RIS

Content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI.

Please wait… references are loading.
10.1088/1742-6596/1799/1/012012