Paper The following article is Open access

Methods for efficiency improvement of the semi-closed oxy-fuel combustion combined cycle

, , , and

Published under licence by IOP Publishing Ltd
, , Citation A N Rogalev et al 2018 J. Phys.: Conf. Ser. 1111 012003 DOI 10.1088/1742-6596/1111/1/012003

1742-6596/1111/1/012003

Abstract

The paper presents thermal schemes of the semi-closed oxy-fuel combustion combined cycle with preliminary cooling of the coolant flow. The first scheme involves the coolant flow preliminary cooling in a surface heat exchanger. The heated agent is a part of condensate taken from the steam turbine circuit. The net efficiency improvement against the base cycle is 3.2% for the working fluid initial temperature of 1700°C. The coolant flow temperature is reduced down to 150°C. The second scheme involves injection of the water taken from the cooler-separator. In this case the power facility net efficiency improvement may be up to 1.5%.

Export citation and abstract BibTeX RIS

Content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI.

Please wait… references are loading.
10.1088/1742-6596/1111/1/012003