Paper The following article is Open access

Precision AC Power Measurement Based on Differential Sampling System Using ACPJVS

, , , and

Published under licence by IOP Publishing Ltd
, , Citation Lei Wang et al 2018 J. Phys.: Conf. Ser. 1065 052023 DOI 10.1088/1742-6596/1065/5/052023

1742-6596/1065/5/052023

Abstract

This paper introduced an AC power measurement method based on differential sampling system using programmable Josephson voltage standards. The amplitude and phase measurement performance were evaluated in comparing with lock-in amplifier from angle accuracy. The results show that the accuracy is less than 0.1 μrad in measuring phase. Then, we compared the differential sampling system with harmonic power standard device by measuring Fluke 6105A in different angle phases. The results prove that the differential sampling system has good performance in measuring phase and amplitude.

Export citation and abstract BibTeX RIS

Content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI.

Please wait… references are loading.
10.1088/1742-6596/1065/5/052023