The impurity transport in HT-6B Tokamak

, , , , , , , and

Published under licence by IOP Publishing Ltd
, , Citation Huang Rong et al 1993 Acta Phys. Sin. (Overseas Edn) 2 22 DOI 10.1088/1004-423X/2/1/004

1004-423X/2/1/22

Abstract

The quasi-stationary profiles of the impurity ionization stages in HT-6B Tokamak were absolutely determined by monitoring the VUV and visible line emissions. An impurity transport code was set up. The impurity transport coefficients and other parameters about impurities were determined. From the changes of impurity emission profiles, it was concluded that the impurity confinement was improved and the impurity recycling was reduced by the slow magnetic compression along the minor radius. Some characteristics about the impurity transport in this small device are discussed.