Lifetimes in Mg I and Mg II; Beam-Foil Measurements and Numerical Coulomb-Approximation Calculations

, , , and

Published under licence by IOP Publishing Ltd
, , Citation L Liljeby et al 1980 Phys. Scr. 21 805 DOI 10.1088/0031-8949/21/6/005

1402-4896/21/6/805

Abstract

Lifetime measurements using the beam-foil technique have been made for 10 levels in Mg I and for 11 levels in Mg II. Lifetimes have been calculated for the same levels using the numerical Coulomb-approximation (NCA) method, and the results are compared with the experimental data. Whereas good agreement exists between theory and experiment for Mg II levels and for some of the low lying Mg I levels, there are large disagreements for some higher lying levels in Mg I. Results from NCA calculations on ionized elements in the Mg I sequence are compared with experimental data. In some but not every case the NCA results agree with experimental data, as for Mg I.

Export citation and abstract BibTeX RIS

Please wait… references are loading.