Continuously pumped continuous-flow iodine laser

, , , and

©, 1977 American Institute of Physics.
, , Citation Tamara L Andreeva et al 1977 Sov. J. Quantum Electron. 7 1230 DOI 10.1070/QE1977v007n10ABEH012846

0049-1748/7/10/1230

Abstract

Experimental results are presented of an investigation into the operation of a continuous-flow iodine laser. A high-pressure mercury lamp was used as the pump source, and a laser output power of around 1 W obtained. It is shown that a laser of this type, pumped by standard mercury lamps can have an efficiency of ~ 1% in converting electrical energy into light.

Export citation and abstract BibTeX RIS