An advanced neutral particle analyzer (ANPA) capable of simultaneously measuring hydrogen and deuterium ions of energies up to 45 keV has recently been developed for use on the Madison Symmetric Torus. The charge-to-mass separation allows for separate analysis of bulk deuterium ions and hydrogen ions injected with a 1 MW, 25 keV neutral beam. Orientation of the ANPA allows sampling of different regions of ion velocity space; a radial viewport favors collection of ions with high v⊥/|v| while a recently installed tangential viewport favors ions with high v||/|v|, such as those from the core-localized fast ion population created by the neutral beam. Signals are observed in the ANPA's highest energy channels during periodic magnetic reconnection events, which are drivers of anisotropic, non-Maxwellian ion energization in the reversed-field pinch. ANPA signal strength is dependent on the background neutral density, which also increases during magnetic reconnection events, so careful analysis must be performed to identify the true change in the ion distribution. A Monte Carlo neutral particle tracing code (NENE) is used to reconstruct neutral density profiles based on Dα line emission, which is measured using a 16-chord filtered photodiode array.
Skip Nav Destination
Article navigation
October 2012
Research Article|
June 08 2012
Time-resolved ion energy distribution measurements using an advanced neutral particle analyzer on the MST reversed-field pincha)
S. Eilerman;
S. Eilerman
b)
1
University of Wisconsin–Madison
, Madison, Wisconsin 53706, USA
Search for other works by this author on:
J. K. Anderson;
J. K. Anderson
1
University of Wisconsin–Madison
, Madison, Wisconsin 53706, USA
Search for other works by this author on:
J. A. Reusch;
J. A. Reusch
1
University of Wisconsin–Madison
, Madison, Wisconsin 53706, USA
Search for other works by this author on:
D. Liu;
D. Liu
2
University of California–Irvine
, Irvine, California 92697, USA
Search for other works by this author on:
G. Fiksel;
G. Fiksel
3
University of Rochester
, Rochester, New York 14623, USA
Search for other works by this author on:
S. Polosatkin;
S. Polosatkin
4
Budker Institute of Nuclear Physics SB RAS
, Novosibirsk, Russia
Search for other works by this author on:
V. Belykh
V. Belykh
4
Budker Institute of Nuclear Physics SB RAS
, Novosibirsk, Russia
Search for other works by this author on:
a)
Contributed paper, published as part of the Proceedings of the 19th Topical Conference on High-Temperature Plasma Diagnostics, Monterey, California, May 2012.
Rev. Sci. Instrum. 83, 10D302 (2012)
Article history
Received:
May 07 2012
Accepted:
May 24 2012
Citation
S. Eilerman, J. K. Anderson, J. A. Reusch, D. Liu, G. Fiksel, S. Polosatkin, V. Belykh; Time-resolved ion energy distribution measurements using an advanced neutral particle analyzer on the MST reversed-field pinch. Rev. Sci. Instrum. 1 October 2012; 83 (10): 10D302. https://doi.org/10.1063/1.4728312
Download citation file:
Sign in
Don't already have an account? Register
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Sign in via your Institution
Sign in via your InstitutionPay-Per-View Access
$40.00
Citing articles via
Method of kinetic energy reconstruction from time-of-flight mass spectra
A. Ngai, K. Dulitz, et al.
An ultracompact scanning tunneling microscope within a Φ 10 piezo tube in a 20 T superconducting magnet