Dtsch Med Wochenschr 2016; 141(18): e166-e172
DOI: 10.1055/s-0042-112345
Fachwissen
Originalarbeit
© Georg Thieme Verlag KG Stuttgart · New York

WeanNet: Das Netzwerk von Weaning-Einheiten der Deutschen Gesellschaft für Pneumologie und Beatmungsmedizin (DGP)

Epidemiologie und Outcome bei Patienten im prolongierten WeaningWeanNet: The network of weaning units of the DGP (Deutsche Gesellschaft für Pneumologie und Beatmungsmedizin) – results to epidemiology an outcome in patients with prolonged weaning
WeanNet Study Group
Further Information

Publication History

Publication Date:
06 September 2016 (online)

Zusammenfassung

Hintergrund | Bei 40 % aller beatmungspflichtigen Patienten gibt es Probleme bei der Respiratorentwöhnung (Weaning). Ein prolongiertes Weaning geht mit einer erhöhten Mortalität einher.

Methodik | In dieser Studie werden erstmals Daten zur Epidemiologie und zum Outcome von 6899 Patienten mit prolongiertem Weaning aus dem Register der Weaningzentren (WZ) im WeanNet veröffentlicht.

Ergebnisse | Die Mehrzahl der Patienten (62,2 %) konnte erfolgreich vom Respirator entwöhnt werden und verließ das Weaningzentrum ohne invasive Beatmung nach median 33 Tagen. Die Patienten mit prolongiertem Weaning litten an einer ausgeprägten Komorbidität (im Median 5 relevante Begleiterkrankungen). Nach prolongiertem Weaning war bei 19,4 % der Patienten eine nicht-invasive Beatmung (NIV), verursacht durch eine chronisch ventilatorische Insuffizienz, erforderlich. Die Patienten, die mit NIV entlassen wurden, waren signifikant jünger als der Durchschnitt (68 vs. 71 Jahre). Bei 22,9 % war das Weaning nicht erfolgreich mit nachfolgender, dauerhafter invasiver Beatmung. Patienten mit chronisch obstruktiver Lungenerkrankung (COPD) als führender Ursache für die mechanische Beatmung wurden im Vergleich zu anderen Ursachen seltener vollständig vom Respirator entwöhnt und häufiger mit NIV zur außerklinischen Beatmung versorgt. Insgesamt 1027 der 6899 Patienten verstarben während der Behandlung im Weaningzentrum (14,9 %).

Schlussfolgerungen | WeanNet kommt in der Versorgung von Patienten mit prolongiertem Weaning ein hoher Stellenwert zu.

Abstract

Background: In 40 % of all ventilated patients weaning is problematic. Prolonged weaning is associated with an increased mortality.

Methods: For the first time, data on epidemiology and outcomes of 6899 patients with prolonged weaning from the WeanNet register are published in this study.

Results: Patients with prolonged weaning suffer from profound comorbidities (median 5 relevant comorbidities). The majority of patients (62.2 %) were successfully weaned from the ventilator and dischared from the weaning unit without invasive ventialtion after a median of 33 days. Caused by chronic ventilatory insufficiency after prolonged weaning, non-invasive ventilation (NIV) was initiated in 19.4% of patients. The patients who were discharged with NIV were significantly younger than the average (68 vs. 71 years).In 22.9 % of the patients weaning definitively failed and continuous invasive ventilation was needed. Compared to other main reasons for mechanical ventilation patients with chronic obstructive pulmonary disease (COPD) were rarely completely weaned from the respirator and more often needed NIV for home mechanical ventilation. In total 14,9 % of the 6899 patients died during the treatment in the weaning unit.

Conclusion: WeanNet is very important in the care of patients with prolonged weaning.

Supporting Information

 
  • Literatur

  • 1 Boles JM, Bion J, Connors A et al. Weaning from mechanical ventilation. Eur Respir J 2007; 29: 1033-1056
  • 2 Cohen IL, Booth FV. Cost containment and mechanical ventilation in the United States. New Horiz 1994; 2: 283-290
  • 3 Funk GC, Anders S, Breyer MK et al. Incidence and outcome of weaning from mechanical ventilation according to new categories. Eur Respir J 2010; 35: 88-94
  • 4 Pilcher DV, Bailey MJ, Treacher DF et al. Outcomes, cost and long term survival of patients referred to a regional weaning centre. Thorax 2005; 60: 187-192
  • 5 Polverino E, Nava S, Ferrer M et al. Patients’ characterization, hospital course and clinical outcomes in five Italian respiratory intensive care units. Intensive Care Med 2010; 36: 137-142
  • 6 Randerath W, Lorenz J, Windisch W et al. Betreuung von Patienten mit maschineller Beatmung unter häuslichen und heimpflegerischen Bedingungen. Positionspapier der Deutsche Gesellschaft für Pneumologie und Beatmungsmedizin and Arbeitsgemeinschaft für Heimbeatmung und Respiratorentwöhnung. Pneumologie 2008; 62: 305-308
  • 7 Scheinhorn DJ, Hassenpflug MS, Votto JJ et al. Ventilator-dependent survivors of catastrophic illness transferred to 23 long-term care hospitals for weaning from prolonged mechanical ventilation. Chest 2007; 131: 76-84
  • 8 Schönhofer B. Das pneumologische Beatmungszentrum – Alles unter einem Dach. Pneumologie 2008; 62: 340-349
  • 9 Schönhofer B. WeanNet: Strukturierte Entwöhnung vom Respirator. Deutsches Arzteblatt 2011; 108: 51-52
  • 10 Windisch W, Brambring J, Budweiser S et al. S2-Leitlinie: Nichtinvasive und invasive Beatmung als Therapie der chronischen respiratorischen Insuffizienz. Pneumologie 2010; 64: 207-240