Arzneimittelforschung 2009; 59(7): 335-344
DOI: 10.1055/s-0031-1296405
Sex Hormones and Inhibitors
Editio Cantor Verlag Aulendorf (Germany)

Cyproterone Acetate Quantification in Human Plasma by High-performance Liquid Chromatography Coupled to Atmospheric Pressure Photoionization Tandem Mass Spectrometry

Application to a comparative pharmacokinetics study
Ney Carter Borges
Synchrophar Assessoria e Desenvolvimento de Projetos Clínicos S/S Ltda., Campinas, SP, Brazil
Department of Internal Medicine, Faculty of Medical Sciences, State University of Campinas (UNICAMP), Campinas, SP, Brazil
,
Ana Mazuqueli
Synchrophar Assessoria e Desenvolvimento de Projetos Clínicos S/S Ltda., Campinas, SP, Brazil
Department of Pharmacology, Faculty of Medical Sciences, State University of Campinas (UNICAMP), Campinas, SP, Brazil
,
Ronilson Agnaldo Moreno
Synchrophar Assessoria e Desenvolvimento de Projetos Clínicos S/S Ltda., Campinas, SP, Brazil
Department of Pharmacology, Faculty of Medical Sciences, State University of Campinas (UNICAMP), Campinas, SP, Brazil
,
Rafael Barrientos Astigarraga
Magabi Pesquisas Clínicas e Farmacêuticas, Jurubatuba, SP, Brazil
,
Carlos Eduardo Sverdloff
Synchrophar Assessoria e Desenvolvimento de Projetos Clínicos S/S Ltda., Campinas, SP, Brazil
Department of Pharmacology, Faculty of Medical Sciences, State University of Campinas (UNICAMP), Campinas, SP, Brazil
,
Paulo Alexandre Rebelo Galvinas
Magabi Pesquisas Clínicas e Farmacêuticas, Jurubatuba, SP, Brazil
,
Mauício Rocha de Magalhães Sampaio
Magabi Pesquisas Clínicas e Farmacêuticas, Jurubatuba, SP, Brazil
,
Washington Moreira da Silva
Magabi Pesquisas Clínicas e Farmacêuticas, Jurubatuba, SP, Brazil
› Author Affiliations
Further Information

Publication History

Publication Date:
13 December 2011 (online)

Abstract

A specific, fast and sensitive high performance liquid chromatography (HPLC) coupled to atmospheric pressure photoionization (APPI) tandem mass spectrometric (LC-MS/MS) assay was developed for the determination of cyproterone (CYP) acetate (CAS 427-51-0) in human plasma. The retention times were 3.26 and 2.90 min for CYP acetate and its internal standard (I. S.) finasteride (FIN), respectively. The overall mean recovery, using liquid/liquid extraction, was found to be 109.0, 107.7 and 100.3%, for low, medium and high concentrations, respectively. Calibration curves were linear in the concentration range of 0.1–50.0 ng/ml, and the lower limit of quantification (LLOQ) was 0.1 ng/ml. The LLOQ, 0.1 ng/ml, was sensitive enough for detecting terminal phase concentrations of the drug. Inter-batch precision of the method ranged from 2.2 to 5.55%, while Inter-batch accuracy ranged from 95.5 to 100.0%. Intra-batch precision ranged from 1.8 to 5.6%, while Intra-batch accuracy ranged from 92.0 to 99.4% at concentrations of 0.3 ng/ml, 20.0 and 40.0 ng/ml. The developed method was applied to a bioequivalenc study of CYP acetate in a group of 44 female volunteers at a single oral dose of a 2 mg tablet, in a combination of ethinylestradiol/CYP acetate (0.25/2 mg). The plasma concentration of CYP acetate did not differ significantly after administration of both formulations (test formulation and the reference one). The geometric mean and respective 90% CI of CYP acetate test/reference percent ratios were 90.66% (84.39–97.40%) for Cmax and 96.20% (90.45-102.33%) for AUC0–t.

 
  • References

  • 1 Baumann A, Kulmann H, Gorkov V, Mahler M, Kuhnz W. Radioimmunological analysis of cyproterone acetate in human serum. Comparison with a gas chromatographic/mass spectrometric method and influence of each method on the outcome of a bioequivalence trial. Arzneimittelforschung. 1996; 46: 412-418
  • 2 Speck U, Wendt H, Schulze PE, Jentsch D. Bio-availability and pharmacokinetics of cyproterone acetate–14 C and ethinyloestradiol-3H after oral administration as a coated tablet (SH B 209 AB). Contraception. 1976; 14: 151-163
  • 3 Dusterberg B. Plasma levels of levonorgestrel, gestodene, norethisterone and cyproterone acetate on single-dose subcutaneous administration in oily solution in the rat, beagle and rhesus monkey. Steroids. 1984; 43: 43-56
  • 4 Fiet J, Giton F, Boudi A, Boudou P, Vexiau P, Galons H et al Highly sensitive and specific time-resolved fluoroimmu-noassay (TR-FIA) of cyproterone acetate and free cyproterone. J Steroid Biochem Mol Biol. 2000; 75: 315-322
  • 5 Kuhnz W, Kulmann Ft, Fuhrmeister A. Investigation into the age-dependence of the pharmacokinetics of cyproterone acetate in healthy male volunteers. Eur J Clin Pharmacol. 1997; 53: 75-80
  • 6 Nieuweboer B, Lubke K. Radioimmunological determination of cyproterone acetate. Horm Res. 1977; 8: 210-218
  • 7 Bebawy LI, Mostafa AA, Refaat HH. Different methods for the determination of gestodene, and cyproterone acetate in raw material and dosage forms. J Pharm Biomed Anal. 2001; 25: 425-436
  • 8 Cannell GR, Mortimer RH, Thomas MJ. High-performance liquid chromatographic estimation of cyproterone acetate in human plasma. J Chromatogr. 1981; 226: 492-497
  • 9 Christiaens B, Fillet M, Chiap P, Rbeida O, Ceccato A, Streel B et al Fully automated method for the liquid chromatographic-tandem mass spectrometric determination of cyproterone acetate in human plasma using restricted access material for on-line sample clean-up. J Chromatogr A. 2004; 1056: 105-110
  • 10 Dikkeschei LD, Wolthers BG, de Ruyter-Buitenhuis AW, Nagel GT, Sleijfer DT, Willemse PH et al Determination of megestrol acetate and cyproterone acetate in serum of patients with advanced breast cancer by high-performance liquid chromatography. J Chromatogr. 1990; 529: 145-154
  • 11 Frith RG, Phillipou G. 15-Hydroxycyproterone acetate and cyproterone acetate levels in plasma and urine. J Chromatogr. 1985; 338: 179-186
  • 12 Yodo K, Saisho S, Shimozawa K, Yata J. A reversed-phase high-performance liquid chromatographic method for the simultaneous determination of serum concentrations of cyproterone acetate and 15 beta-hydroxycyproterone acetate. Endocrinol Jpn. 1988; 35: 143-148
  • 13 Matejicek D, Kuban V. High performance liquid chromatography/ion-trap mass spectrometry for separation and simultaneous determination of ethynylestradiol, gestodene, levonorgestrel, cyproterone acetate and desogestrel. Anal Chim Acta. 2007; 588: 304-315
  • 14 Viswanathan CT, Bansal S, Booth B, DeStefano AJ, Rose MJ, Sailstad J et al Quantitative bioanalytical methods validation and implementation: best practices for chromatographic and ligand binding assays. Pharm Res. 2007; 24: 1962-1973
  • 15 Pereira AS, Mendes GD, Oliveira LS, Valle HF, De Nucci G. Atmospheric pressure photoionization applied to quantitation of cyproterone acetate in human plasma. J Chromatogr Sci. 2005; 43: 513-517
  • 16 Robb DB, Covey TR, Bruins AP. Atmospheric pressure photoionization: an ionization method for liquid chromatography-mass spectrometry. Anal Chem. 2000; 72: 3653-3659
  • 17 Leinonen A, Kuuranne T, Kostiainen R. Liquid chromatography/mass spectrometry in anabolic steroid analysis-optimization and comparison of three ionization techniques: electrospray ionization, atmospheric pressure chemical ionization and atmospheric pressure photoionization. J Mass Spectrom. 2002; 37: 693-698
  • 18 Cai Y, Kingery D, McConnell O, Bach 2nd AC. Advantages of atmospheric pressure photoionization mass spectrometry in support of drug discovery. Rapid Commun Mass Spectrom. 2005; 19: 1717-1724