CC BY-NC-ND 4.0 · Endoscopy 2023; 55(S 01): E153-E154
DOI: 10.1055/a-1956-0511
E-Videos

Endoscopic ultrasound-guided antegrade stenting using a novel flower-type fully covered self-expandable metal stent

Yoshitaro Yamamoto
2nd Department of Internal Medicine, Osaka Medical and Pharmaceutical University, Osaka, Japan
,
Takeshi Ogura
2nd Department of Internal Medicine, Osaka Medical and Pharmaceutical University, Osaka, Japan
,
Jyunichi Kawai
2nd Department of Internal Medicine, Osaka Medical and Pharmaceutical University, Osaka, Japan
,
Masahiro Yamamura
2nd Department of Internal Medicine, Osaka Medical and Pharmaceutical University, Osaka, Japan
,
Kazuya Ueshima
2nd Department of Internal Medicine, Osaka Medical and Pharmaceutical University, Osaka, Japan
,
Hiroki Nishikawa
2nd Department of Internal Medicine, Osaka Medical and Pharmaceutical University, Osaka, Japan
› Author Affiliations

Endoscopic ultrasound-guided biliary drainage is usually indicated for patients for whom endoscopic retrograde cholangiopancreatography (ERCP) fails [1]. With recent improvements in chemotherapeutic regimens, longer stent patency is also required. To obtain longer stent patency, EUS-guided antegrade stenting (EUS-AGS) combined with EUS-guided hepaticojejunostomy has recently been attempted [2]. Compared with an uncovered self-expandable metal stent (UCSEMS), stent patency might be longer with a fully covered self-expandable metal stent (FCSEMS) [3] [4]. On the other hand, a FCSEMS shows higher axial force compared to a UCSEMS and carries a higher risk of cystic duct obstruction despite longer stent patency [5].

To overcome these issues, a novel FCSEMS (flower-type; S&G Biotech, Gyeonggi, South Korea) is now available in Japan ([Fig. 1]). This stent is a FCSEMS with an 8-Fr stent delivery system covered by expanded polytetrafluoroethylene. In addition, this stent has a five-petal shape with grooves on the sides, parallel to the long axis. The low axial force reduces the chances of stent kinking, and the unique form prevents acute cholecystitis. Herein, we describe technical tips for EUS-AGS using this stent.

Zoom Image
Fig. 1 The novel fully covered self-expandable metal stent is covered by expanded polytetrafluoroethylene (left) and has a five-petal shape with grooves on the sides (right), parallel to the long axis.

After puncturing the intrahepatic bile duct using a 22-G needle (Sono Tip Pro Control; Medi-Globe, Achenmuhle, Germany), a 0.018-inch guidewire (Fielder 18; Asahi Intecc, Aichi, Japan) was then inserted into the biliary tract, followed by the ERCP catheter ([Fig. 2]).

Zoom Image
Fig. 2 Endoscopic ultrasound-guided cholangiography demonstrates obstruction of the lower common bile duct.

Cholangiography showed lower common bile duct (CBD) obstruction. The guidewire was then successfully inserted into the lower CBD across the stricture site ([Fig. 3]). Next, the stent delivery system of the novel FCSEMS was inserted and successfully deployed from the lower CBD to the upper CBD ([Fig. 4]). Finally, EUS-guided hepaticojejunostomy using a partially covered SEMS (BileRush Advance; Piolax, Yokohama, Japan) was performed without any adverse events ([Fig. 5], [Video 1]).

Zoom Image
Fig. 3 The guidewire is advanced into the lower common bile duct across the stricture site.
Zoom Image
Fig. 4 An endoscopic ultrasound-guided antegrade covered metal stent is placed across the bile duct stenosis above the ampulla of Vater.
Zoom Image
Fig. 5 A partially covered self-expandable metal stent is deployed from the intrahepatic bile duct to the stomach.

Video 1 Cholangiography shows lower bile duct obstruction. Endoscopic ultrasound-guided antegrade stenting using a novel flower-type fully covered self-expandable metal stent is successfully deployed from the lower common bile duct to the upper common bile duct. Finally, endoscopic ultrasound-guided hepaticojejunostomy using a partially covered self-expandable metal stent is performed.


Quality:

In conclusion, EUS-AGS using a novel flower-type FCSEMS may be useful to prevent acute cholecystitis.

Endoscopy_UCTN_Code_TTT_1AR_2AZ

Endoscopy E-Videos
https://eref.thieme.de/e-videos

Endoscopy E-Videos is an open access online section, reporting on interesting cases and new techniques in gastroenterological endoscopy. All papers include a high quality video and all contributions are freely accessible online. Processing charges apply (currently EUR 375), discounts and wavers acc. to HINARI are available.

This section has its own submission website at https://mc.manuscriptcentral.com/e-videos



Publication History

Article published online:
28 October 2022

© 2022. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/)

Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany

 
  • References

  • 1 Khashab MA, Levy ML, Itoi T. et al. EUS-guided biliary drainage. Gastrointest Endosc 2015; 82: 993-1001
  • 2 Ogura T, Kitano M, Takenaka M. et al. Multicenter prospective evaluation study of endoscopic ultrasound-guided hepaticogastrostomy combined with antegrade stenting (with video). Dig Endosc 2018; 30: 252-259
  • 3 Kitano M, Yamashita Y, Tanaka K. et al. Covered self-expandable metal stents with an anti-migration system improve patency duration without increased complications compared with uncovered stents for distal biliary obstruction caused by pancreatic carcinoma: A randomized multicenter trial. Am J Gatroenterol 2013; 108: 1713-1722
  • 4 Saleem A, Leggett CL, Murad HM. et al. Meta-analysis of randomized trials comparing the patency of covered and uncovered self-expandable metal stents for palliation of distal malignant bile duct obstruction. Gastrointest Endosc 2011; 74: 321-327
  • 5 Nakai Y, Isayama H, Kawakubo K. et al. Metallic stent with high axial force as a risk factor for cholecystitis in distal malignant biliary obstruction. J Gastroenterol Hepatol 2014; 29: 1557-1562