Endoscopy 2009; 41(5): 468-471
DOI: 10.1055/s-0029-1214603
Case report

© Georg Thieme Verlag KG Stuttgart · New York

Double-balloon enteroscopy-assisted virtual chromoendoscopy for small-bowel disorders – a case series

H.  Neumann1 , L.  C.  Fry1 , M.  Bellutti1 , P.  Malfertheiner1 , K.  Mönkemüller1
  • 1Department of Gastroenterology, Hepatology and Infectious Diseases, Otto-von-Guericke University, Magdeburg, Germany
Further Information

Publication History

submitted 16 October 2008

accepted after revision 9 February 2009

Publication Date:
05 May 2009 (online)

The Fujinon intelligent color enhancement (FICE) system is a new, virtual chromoendoscopy technique that enhances mucosal visibility. The aim of this study was to assess the utility of double-balloon enteroscopy (DBE) with FICE technology (EPX-4400 processor, Japan) for the characterization of various small-bowel diseases. Overall, a total of 574 endoscopic pictures were obtained and analyzed. FICE was found to be a helpful method for the evaluation of adenomatous small-bowel polyps and angiodysplasias. Its use for the characterization of celiac and Crohn’s disease appears to be limited. Overall, FICE may become a useful method that aids in characterization and provides new insights to small-bowel pathologies.

References

  • 1 Kiesslich R, Neurath M F. Chromoendoscopy with indigocarmine improves the detection of adenomatous and nonadenomatous lesions in the colon.  Endoscopy. 2001;  33 1001-1006
  • 2 Brooker J C, Saunders B P, Shah S G. et al . Total colonic dye-spray increases the detection of diminutive adenomas during routine colonoscopy: a randomized controlled trial.  Gastrointest Endosc. 2002;  56 333-338
  • 3 Hurlstone D P, Cross S S, Slater R. et al . Detecting diminutive colorectal lesions at colonoscopy: a randomized controlled trial of pan-colonic versus targeted chromoendoscopy.  Gut. 2004;  53 376-380
  • 4 Pohl J, May A, Rabenstein T. et al . Computed virtual chromoendoscopy: a new tool for enhancing tissue surface structures.  Endoscopy. 2007;  39 80-83
  • 5 Gono K, Yamazaki K, Doguchi N. et al . Endoscopic observation of tissue by narrow band illumination.  Opt Rev. 2003;  10 1-5
  • 6 Song L M, Adler D G. ASGE Technology Committee . Narrow band imaging and multiband imaging.  Gastrointest Endosc. 2008;  67 581-589
  • 7 Pohl J, Nguyen-Tat M, Pech O. et al . Computed virtual chromoendoscopy for classification of small colorectal lesions: a prospective comparative study.  Am J Gastroenterol. 2008;  103 562-569
  • 8 Coriat R, Chryssostalis A, Zeitoun J D. et al . Computed virtual chromoendoscopy system (FICE): a new tool for upper endoscopy?.  Gastroenterol Clin Biol. 2008;  32 363-369
  • 9 Pohl J, May A, Rabenstein T. et al . Comparison of computed virtual chromoendoscopy and conventional chromoendoscopy with acetic acid for detection of neoplasia in Barrett’s esophagus.  Endoscopy. 2007;  39 594-598
  • 10 Mönkemüller K, Fry L C, Ebert M. et al . Feasibility of double-balloon enteroscopy-assisted chromoendoscopy of the small bowel in patients with familial adenomatous polyposis.  Endoscopy. 2007;  39 52-57
  • 11 Ringold D A, Sikka S, Banerjee B. High-contrast imaging (FICE) improves visualization of gastrointestinal vascular ectasias.  Endoscopy. 2008;  40 Suppl 2 E26

K. MönkemüllerMD, PhD, FASGE 

Department of Gastroenterology, Hepatology and Infectious Diseases
Otto-von-Guericke University

Leipziger Str. 44
39120 Magdeburg
Germany

Fax: +49-391-6713105

Email: Klaus.Moenkemueller@med.ovgu.de

    >