Am J Perinatol 2010; 27(8): 641-648
DOI: 10.1055/s-0030-1249367
© Thieme Medical Publishers

Nomogram of Fetal Liver Volume by Three-Dimensional Ultrasonography at 27 to 38 Weeks of Pregnancy Using a New Multiplanar Technique

Maria Christina dos Santos Rizzi1 , Edward Araujo Júnior1 , Luciano Marcondes Machado Nardozza1 , Angélica Lemos Debs Diniz2 , Liliam Cristine Rolo1 , Antonio Fernandes Moron1
  • 1Department of Obstetrics, Federal University of São Paulo (UNIFESP), São Paulo, SP, Brazil
  • 2Department of Gynecology and Obstetrics, Federal University of Uberlândia (UFU), Uberlândia, MG, Brazil
Further Information

Publication History

Publication Date:
02 March 2010 (online)

ABSTRACT

We sought to establish normative data for fetal liver volume (FLV) between 27 and 38 weeks' gestation using three-dimensional ultrasonography. The study design was a longitudinal prospective study involving 53 participants. A total of 250 FLV measurements were obtained, using the multiplanar method with 3.0-mm intervals. Polynomial regressions with adjustments using the determination coefficient (R 2) were used to assess the correlation between FLV and gestational age (GA) and fetal parameters (biparietal diameter, head circumference, abdominal circumference, and estimated fetal weight). The mean, standard deviation, and median, minimum, and maximum values were calculated for each gestational age. The intraclass correlation coefficient (ICC) was used to determine inter- and intraobserver reliability. There was a high correlation between FLV and GA. The mean FLV went from 43.5 ± 7.6 cm3 (29.1 to 62.2 cm3) to 130.5 ± 20.1 cm3 (87.5 to 191.1 cm3). There was a high correlation between FLV and all fetal biometric parameters (all p < 0.0001). Intraobserver and interobserver correlations were excellent with an ICC = 0.993 and 0.984, respectively. There was a high correlation between GA and biometric parameters. Reference limits were generated for FLV between 27 and 38 weeks. FLV is highly reproducible.

REFERENCES

  • 1 Langman J. Langman's Medical Embryology. Baltimore; Williams & Wilkins 1995
  • 2 Champetier J, Yver R, Tomasella T. Functional anatomy of the liver of the human fetus: applications to ultrasonography.  Surg Radiol Anat. 1989;  11 53-62
  • 3 Murao F, Takamori H, Hata K, Hata T, Kitao M. Fetal liver measurements by ultrasonography.  Int J Gynaecol Obstet. 1987;  25 381-385
  • 4 Vintzileos A M, Neckles S, Campbell W A, Andreoli Jr J W, Kaplan B M, Nochimson D J. Fetal liver ultrasound measurements during normal pregnancy.  Obstet Gynecol. 1985;  66 477-480
  • 5 Riccabona M, Nelson T R, Pretorius D H. Three-dimensional ultrasound: accuracy of distance and volume measurements.  Ultrasound Obstet Gynecol. 1996;  7 429-434
  • 6 Chang C H, Yu C H, Chang F M, Ko H C, Chen H Y. Assessment of fetal adrenal gland volume using three-dimensional ultrasound.  Ultrasound Med Biol. 2002;  28 1383-1387
  • 7 Chang C H, Yu C H, Chang F M, Ko H C, Chen H Y. The assessment of normal fetal brain volume by 3-D ultrasound.  Ultrasound Med Biol. 2003;  29 1267-1272
  • 8 Peralta C F, Cavoretto P, Csapo B, Falcon O, Nicolaides K H. Lung and heart volumes by three-dimensional ultrasound in normal fetuses at 12-32 weeks' gestation.  Ultrasound Obstet Gynecol. 2006;  27 128-133
  • 9 Raine-Fenning N J, Clewes J S, Kendall N R, Bunkheila A K, Campbell B K, Johnson I R. The interobserver reliability and validity of volume calculation from three-dimensional ultrasound datasets in the in vitro setting.  Ultrasound Obstet Gynecol. 2003;  21 283-291
  • 10 Ruano R, Martinovic J, Dommergues M, Aubry M C, Dumez Y, Benachi A. Accuracy of fetal lung volume assessed by three-dimensional sonography.  Ultrasound Obstet Gynecol. 2005;  26 725-730
  • 11 Boito S M, Struijk P C, Ursem N T, Stijnen T, Wladimiroff J W. Assessment of fetal liver volume and umbilical venous volume flow in pregnancies complicated by insulin-dependent diabetes mellitus.  BJOG. 2003;  110 1007-1013
  • 12 Chang C H, Yu C H, Chang F M, Ko H C, Chen H Y. The assessment of normal fetal liver volume by three-dimensional ultrasound.  Ultrasound Med Biol. 2003;  29 1123-1129
  • 13 Chang C H, Yu C H, Ko H C, Chen C L, Chang F M. Predicting fetal growth restriction with liver volume by three-dimensional ultrasound: efficacy evaluation.  Ultrasound Med Biol. 2006;  32 13-17
  • 14 Kuno A, Hayashi Y, Akiyama M et al.. Three-dimensional sonographic measurement of liver volume in the small-for-gestational-age fetus.  J Ultrasound Med. 2002;  21 361-366
  • 15 Bland J M, Altman D G. Statistical methods for assessing agreement between two methods of clinical measurement.  Lancet. 1986;  1 307-310
  • 16 Kalache K D, Espinoza J, Chaiworapongsa T et al.. Three-dimensional ultrasound fetal lung volume measurement: a systematic study comparing the multiplanar method with the rotational (VOCAL) technique.  Ultrasound Obstet Gynecol. 2003;  21 111-118
  • 17 Gerards F A, Twisk J W, Bakker M, Barkhof F, van Vugt J M. Fetal lung volume: three-dimensional ultrasonography compared with magnetic resonance imaging.  Ultrasound Obstet Gynecol. 2007;  29 533-536
  • 18 Peralta C F, Kazan-Tannus J F, Bunduki V et al.. Evaluation of the agreement between 3-dimensional ultrasonography and magnetic resonance imaging for fetal lung volume measurement.  J Ultrasound Med. 2006;  25 461-467
  • 19 Ruano R, Joubin L, Sonigo P et al.. Fetal lung volume estimated by 3-dimensional ultrasonography and magnetic resonance imaging in cases with isolated congenital diaphragmatic hernia.  J Ultrasound Med. 2004;  23 353-358
  • 20 Araujo Júnior E, De Oliveira P S, Nardozza L M et al.. Fetal lung volume in fetuses with urinary tract malformations: comparison by 2D-, 3D-sonography and magnetic resonance imaging.  J Matern Fetal Neonatal Med. 2010;  23 60-68
  • 21 Chang F M, Hsu K F, Ko H C et al.. Three-dimensional ultrasound assessment of fetal liver volume in normal pregnancy: a comparison of reproducibility with two-dimensional ultrasound and a search for a volume constant.  Ultrasound Med Biol. 1997;  23 381-389

Edward Araujo JúniorPh.D. 

Rua Carlos Weber, 950 apto. 113 Visage

Alto da Lapa, São Paulo–SP, Brazil CEP 05303-000

Email: araujojred@terra.com.br

    >