Issue 12, 2014

Solid phase microextraction of trace levels of copper in serum samples of hepatitis B patients, on activated carbon cloth modified with an ionic liquid by using a syringe mountable filter technique

Abstract

A simple, inexpensive and miniaturized solid phase microextraction method using a syringe mountable filter as a substitute for batch and column techniques was developed for rapid extraction and determination of copper ions (Cu2+). Activated carbon cloth (ACC), modified with the ionic liquid (IL), 1-butyl-3-methylimidazolium hexafluorophosphate [C4MIM][PF6], was used as sorbent. The modified ACC was packed on mountable membrane filter in a plastic syringe system. The surface modification, elemental composition and characterization of ACC were confirmed using scanning electron microscopy, energy dispersive X-ray spectroscopy and Fourier-transform infrared spectroscopy. The sample solution treated with a complexing reagent, ammonium pyrrolidine dithiocarbamate, was drawn into the syringe filled with IL-ACC and dispensed manually. Then the Cu2+ complex sorbed on the IL-ACC was quantitatively eluted by drawing and dispensing of different concentrations of acids. The influence of different variables on the extraction efficiency, including the concentration of ligand, pH, sample volume, eluent type, concentration and volume, and interfering ions was investigated using flame atomic absorption spectrometry. In order to validate the developed method, a certified reference material (CRM) of human serum (Sero-M10181®) was analyzed, which indicated a non-significant difference in the experimental and certified values. The proposed method was successfully applied for the determination of Cu2+ in serum samples of hepatitis B patients and healthy controls.

Graphical abstract: Solid phase microextraction of trace levels of copper in serum samples of hepatitis B patients, on activated carbon cloth modified with an ionic liquid by using a syringe mountable filter technique

Article information

Article type
Paper
Submitted
05 Sep 2014
Accepted
06 Oct 2014
First published
06 Oct 2014

J. Anal. At. Spectrom., 2014,29, 2362-2370

Solid phase microextraction of trace levels of copper in serum samples of hepatitis B patients, on activated carbon cloth modified with an ionic liquid by using a syringe mountable filter technique

S. A. Arain, T. G. Kazi, H. I. Afridi, A. R. Abbasi, J. A. Baig, A. H. Panhwar and N. Ullah, J. Anal. At. Spectrom., 2014, 29, 2362 DOI: 10.1039/C4JA00304G

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements