Issue 18, 2019

Application of a novel diol-based porous organic polymer to the determination of trace-level tetracyclines in water

Abstract

The solid phase extraction (SPE) method is often used to enrich trace antibiotics in water before analysis by high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS), but the improvement of extraction efficiency has always been the hot issue in this method, which may be realized by developing new SPE materials and optimizing extraction conditions. Tetracyclines (TCs) are a class of common antibiotics, but appropriate SPE materials specifically used to detect them are lacking. Common SPE materials show low and unstable recoveries during the extraction and detection of TCs. In this study, a novel diol-based porous organic polymer (NTdiol-POP) was used as a new SPE material to detect trace TCs in water. This material has specific adsorptive properties for TCs via hydrogen bonds, electrostatic attractive interactions, and π–π interactions. The results show that the NTdiol-POP cartridges have higher recoveries (83.3–118.1%) for determining TCs than common SPE cartridges. Under optimum SPE conditions using NTdiol-POP, TCs were adsorbed at pH 5.0 and eluted with a solution of formic acid/methanol (7%/93%, v/v). Meanwhile, chromatographic separation conditions and MS/MS parameters in multiple reaction monitoring (MRM) mode were optimized to improve the sensitivity and specificity of the instrumental analysis. The limit of detection varied from 0.078 to 2.18 ng L−1, while the limit of quantification varied from 0.26 to 7.25 ng L−1. An assessment of the matrix effects in drinking water exhibited a slight signal variation for most TCs (−8.4% to 2.5%) except oxytetracycline, for which the detection signals were enhanced by 27.0%. The proposed method was successfully applied to determine the trace TCs in three reservoirs of East China.

Graphical abstract: Application of a novel diol-based porous organic polymer to the determination of trace-level tetracyclines in water

Supplementary files

Article information

Article type
Paper
Submitted
22 Dec 2018
Accepted
04 Apr 2019
First published
04 Apr 2019

Anal. Methods, 2019,11, 2473-2481

Application of a novel diol-based porous organic polymer to the determination of trace-level tetracyclines in water

C. Cui, Z. Cao, S. Zhang, Y. Hu, L. Jiang, S. Yao, H. Ye, Y. Zhou, J. Hu, K. Lin and T. Zhang, Anal. Methods, 2019, 11, 2473 DOI: 10.1039/C8AY02790K

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements