Thank you for visiting nature.com. You are using a browser version with limited support for CSS. To obtain the best experience, we recommend you use a more up to date browser (or turn off compatibility mode in Internet Explorer). In the meantime, to ensure continued support, we are displaying the site without styles and JavaScript.

  • Paper
  • Published:

Evaluation of signal-averaged electrocardiogram in healthy obese women: effects of subcutaneous adipose tissue

Abstract

OBJECTIVE: To determine the correlations between signal-averaged electrocardiography (SAECG) indices and various anthropometric parameters in obese women. SUBJECTS: Twenty-seven healthy obese women (mean age 29.7±9.6 y, mean body mass index 35.2±6.0 kg/m2). MEASUREMENTS: SAECG was performed using a Marquette, MAC 12/15 system. Bidirectional filtering, low-pass filtering 250 Hz and 25, 40 and 80 Hz high-pass filter settings were employed on the same averaged beats. At least 200 beats were averaged to achieve a noise level <1 µV. Body mass index, waist to hip circumference ratio, neck circumference, arm circumference and conicity index were determined for all subjects. Skinfold thicknesses were measured in triceps, biceps, subscapular, supra-iliac and para-umbilical regions. RESULTS: Significant correlations were observed between the root mean square (RMS) voltage of the terminal 40 ms of the filtered QRS complex at 25 and 40 Hz and skinfold thicknesses measured at different sites. Significant correlations were obtained between the noise level at 25 and 40 Hz and skinfold thicknesses measured at subscapular, biceps and triceps regions also. The only SAECG parameter correlated significantly with the noise level was the RMS voltage at 25 and 40 Hz high-pass filter settings. CONCLUSIONS: In obese women SAECG must be performed with 80 Hz high-pass filter setting which eliminates the random noise originating from the subcutaneous adipose tissue. In addition RMS voltage which shows positive linear correlations with the noise level of 25 and 40 Hz high-pass filter settings might be inappropriate for the definition of abnormal SAECG criteria in obese women.

This is a preview of subscription content, access via your institution

Access options

Buy this article

Prices may be subject to local taxes which are calculated during checkout

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Özbey, N., Öncül, A., Azarbaz, M. et al. Evaluation of signal-averaged electrocardiogram in healthy obese women: effects of subcutaneous adipose tissue. Int J Obes 21, 658–665 (1997). https://doi.org/10.1038/sj.ijo.0800456

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1038/sj.ijo.0800456

Keywords

This article is cited by

Search

Quick links