Abstract
We present a method to determine the bulk temperature of a single crystal diamond sample at an X-Ray free electron laser using inelastic X-ray scattering. The experiment was performed at the high energy density instrument at the European XFEL GmbH, Germany. The technique, based on inelastic X-ray scattering and the principle of detailed balance, was demonstrated to give accurate temperature measurements, within \(8\%\) for both room temperature diamond and heated diamond to 500 K. Here, the temperature was increased in a controlled way using a resistive heater to test theoretical predictions of the scaling of the signal with temperature. The method was tested by validating the energy of the phonon modes with previous measurements made at room temperature using inelastic X-ray scattering and neutron scattering techniques. This technique could be used to determine the bulk temperature in transient systems with a temporal resolution of 50 fs and for which accurate measurements of thermodynamic properties are vital to build accurate equation of state and transport models.
Similar content being viewed by others
Introduction
From the thermal shield of a spacecraft during atmospheric re-entry1 to the interior of Jovian planets2, matter is often found at pressures and temperatures that are at the limits of where conventional condensed matter and plasma physics formalisms are valid3. At such extreme conditions, the kinetic energy of the electrons is comparable to the potential energy of interaction between electrons and the nuclei. For these systems, direct and accurate measurements of thermodynamic and transport properties are vital. Extreme states of matter can be produced by dynamic laser-driven compression4,5,6 and laser heating techniques7,8. These methods can excite a material into a transient state of simultaneously high density and temperature, and thereby enable access to previously unexplored regions of phase space. State-of-the-art experiments investigate the properties of materials driven into these conditions by coupling high-energy lasers with suitable probing techniques9,10. In particular, X-ray scattering has proven to be a powerful tool for determining the structure and density, and the development of X-ray free electron lasers (XFELs) has led to improved understanding of materials under dynamic compression conditions11,12,13,14,15,16,17,18. While it is possible to directly investigate the structure of a material under dynamic compression, measuring the temperature remains a challenge. In these experiments, the temperature has typically been estimated from hydrodynamic simulations or inferred through the use of streaked optical pyrometry, which measures the thermal self-emission of the surface of a material. However, this technique is only valid at temperatures in excess of 4,000 K19,20 and relies on assumptions of the behaviour of emissivity at extreme conditions. Extended X-ray absorption fine structure measurements (EXAFS) have been made to investigate simultaneously the density and temperature in compressed matter21. However, this technique requires a knowledge of the pressure dependent Debye temperature. Diffraction-based Debye Waller measurements have also been proposed as a temperature diagnostic for compressed matter, and have been demonstrated from ultrafast-heated gold using MeV electron diffraction techniques22. A solution to this temperature measurement problem may arise through the use of inelastic X-ray scattering to measure the dynamic structure factor, \(S(Q, \omega )\). Inelastic X-ray scattering with electronvolt to kilo-electronvolt resolution (i.e. Thomson scattering of “free” electrons) has been well-established for determining the Fermi temperature, densities and ionisation state of dynamically compressed matter, and has been demonstrated at both large laser facilities23,24,25,26 and at hard XFELs27,28. By making use of milli-electronvolt (meV) resolution inelastic X-ray scattering, one can measure changes in the X-ray photon energy due to scattering from collective excitations such as phonons in a solid29,30,31,32, acoustic waves in a liquid33,34,35 or ion acoustic modes in the warm dense matter regime36,37. By probing these low-energy collective atomic/ionic motions and employing the principle of detailed balance38, one can directly infer the temperature of the atomic subsystem in thermal equilibrium. Here, we describe the use of the European XFEL39,40,41,42 to measure the dynamic structure factor of single crystal (100) diamond at room temperature and at 500 K, with meV resolution. The lattice temperature is determined from the asymmetry of the measured inelastic scattering spectra and found to be within \(8\%\) of that measured by a thermocouple attached to the sample holder, comparable to previous measurements conducted at third generation synchrotron facilities43. We describe the experimental setup, and present the approach to process the data and subsequently extract temperatures. By taking full advantage of the XFEL, this technique could be used to make time-resolved temperature measurements of transient, laser driven states of matter.
Experimental details
The experiments were performed at the high energy density (HED) instrument at the European XFEL GmbH, Germany. The experimental setup is shown in Fig. 1, and is described in detail by Wollenweber et al.44 The self-amplified spontaneous emission (SASE) X-ray beam mode delivered single pulses with \(10^{12}\) X-ray photons at a repetition rate of 10 Hz45. The incident X-ray energy was chosen to be 7,492 eV with a bandwidth of \(\frac{\Delta E}{E}=10^{-3}\) to ensure a near backscattering (\(\sim 87.5^{\circ }\)) reflection on the high-resolution monochromator and the spherically diced analyser46. The X-ray beam was first monochromatised to a bandwidth of \(\frac{\Delta E}{E}=10^{-4}\) using a symmetric silicon (111) monochromator in a (+-) non-dispersive configuration, and further monochromatised using a high-resolution symmetric silicon (533) monochromator in a (-+) non-dispersive near backscattering configuration to achieve a bandwidth \(\frac{\Delta E}{E}=4\times 10^{-6}\). After the monochromatisation, the photon number per pulse falls to \(10^{9}\) as calculated from dynamical X-ray diffraction theory47. Beryllium compound refractive lenses, \(9 \, \mathrm{m}\) upstream of the sample, were used to focus the X-ray pulses. To ensure a large probing volume, the sample was positioned out of the best focus plane resulting in an X-ray spot size of 25 \(\upmu\)m.
The focussed and monochromatised X-ray beam was incident onto a 250 \(\upmu\)m thick sample of single crystal diamond from Applied Diamond, Inc., with the surface oriented parallel to the [010] direction. This thickness corresponds to half the attenuation length of the 7,492 eV X-ray photons in diamond, and was chosen to balance the scattering signal and the broadening of the measured spectra due to sample size effects46. In order to minimise quasi-elastic scattering that one would observe in the presence of disorder e.g. grain boundaries, defects, the measurement was made on high-purity single crystal diamond. The measurement was performed on both room temperature and heated diamond at 500 K using a resistive heater. Details of the resistive heater are described in the “Methods” section. Photons scattered from the sample were energy dispersed by three diced single crystal silicon (533) analysers with a cube size of \(1.65\,\mathrm{mm}\times 1.65\,\mathrm{mm}\). The analysers were arranged in a Johann geometry with a 1 m diameter46. The three analysers sit on a common horizontal rail free to move in the vertical direction such that the side analysers are horizontally offset by \(9.4^{\circ }\) with respect to the central analyser. The central analyser was positioned at an angle of \(8^{\circ } \pm 1^{\circ }\) and the sample was vertically tilted by an angle of \(4.3^{\circ }\) towards the monochromator in order to align the scattering vector \(\vec {Q} = \vec {k}_{out} - \vec {k}_{in}\) with the [001] direction within the first Brillouin zone of diamond, and hence to be mostly sensitive to the longitudinal acoustic mode along this direction. For this geometry, the analysers collected photons with momentum transfer of \(||\vec {Q}|| = 0.52 \pm 0.1\,{\AA }^{-1}\) for the central analyser and \(||\vec {Q}|| = 0.81 \pm 0.1\,{\AA }^{-1}\) for the side analysers. The uncertainty on the momentum transfer arises from the distribution of scattering angles collected by the 10 cm diameter spherical diced analysers and corresponds to the \(67\%\) confidence interval.
Photons which are both energy dispersed and focused using the diced silicon crystal analysers were detected using an ePIX100 detector with a pixel size of 50 \(\upmu\)m \(\times\) 50 \(\upmu\)m48. The energy resolution of the entire system is dominated by the intrinsic energy resolution of the (533) reflection of silicon (\(\sim\) 33 meV) and the different geometrical contributions to its broadening i.e. Johann aberration (\(\sim\) 4 meV), pixel contribution (\(\sim\) 7.5 meV), and sample size effects49. This was measured at room temperature using a 500 \(\upmu\)m-thick sample of polymethyl methacrylate (PMMA), as the scattering from this amorphous material is dominated by quasi-elastic scattering. In the heated case, a 250 \(\upmu\)m-thick piece of amorphous \(\hbox {SiO}_2\) was used as a calibrant for the energy resolution, as the melting point of PMMA is around 430 K.
The resolution of each analyser at room temperature, and following resistive heating, was obtained using the data processing procedure described below, and determined by fitting a pseudo-Voigt profile to the obtained quasi-elastic scattering spectra. The experimental data along with their best fit are shown in Fig. 1 in the Supplemental Material. The energy resolutions for each analyser are summarised in Table 1, and examples of the raw data are shown in Fig. 2.
Data processing
For each X-ray pulse, the scattered photons are collected by the spherically diced analyser and are focused on the detector. Given the small inelastic cross section, a single photon counting routine is used to classify each pixel on the detector as a single photon depending on its count value and the count values of the surrounding pixels. The procedure is further discussed in the Supplemental Materials. Example raw data are presented in Fig. 2 and correspond to the summation of the single photons scattered from room temperature diamond at 10 Hz using 95,547 X-ray pulses.
The subsequent spectra are then unwrapped to correct for the curvature of the image of the analysers on the detector. This is done by fitting a quadratic function to each trace in Fig. 2 in order to find a relationship between the non-dispersive axis and the energy dispersive axis. Each pixel is then adjusted based on the fitted relation to obtain a linear trace. The curvature-corrected trace is then integrated along the horizontal direction (non-dispersive direction) to give the experimental data points shown in Fig. 3. The energy transfer is finally constructed from the energy per pixel relation by measuring the displacement of the quasi-elastic component along the energy dispersion axis with the incident X-ray energy and by indexing the zero energy transfer for each analyser with the position of the maximum intensity of the corresponding instrument function.
Fitting procedure and model
The detected scattered intensity, following the data processing described above, can be expressed as the sum of the elastic coherent double differential cross section and the inelastic coherent one-phonon double differential cross section50. Using the second quantisation of the vibrational modes in a solid in terms of the phonon creation and annihilation operators50,51 and assuming thermal equilibrium, one can express the scattered intensity from phonon modes in single crystal diamond in the first Brillouin zone using Eq. (1). The derivation of this expression is presented in the Supplemental materials.
The first Lorentzian accounts for the elastic scattering contribution to the recorded intensity and the summation over \(\lambda\) for the inelastic scattering intensity arises from the different phonon branches, \(\lambda\), in the material. \(\vec {q}\) is the phonon wavevector defined within the first Brillouin zone. \(\omega _{\lambda }(\vec {q})\) is the phonon frequency of the branch \(\lambda\) at wavevector \(\vec {q}\). \(\langle n(\omega _{\lambda }(\vec {q}))\rangle\) is the Bose occupation number of phonons with frequency \(\omega _{\lambda }(\vec {q})\). It is defined as \(\langle n(\omega )\rangle = \big [e^{\hbar \omega \beta }-1\big ]^{-1}\) and \(\beta = \frac {1}{k_B T}\). Finally, \(\hbar \omega\) is the energy exchanged during the scattering event and is counted positive when the photon gains energy during the interaction.
\(R(\hbar \omega , \vec {q})\) is the instrument function as determined by measuring the inelastic scattering spectrum of 500 \(\upmu\)m of PMMA for room temperature, and 250 \(\upmu\)m \(\hbox {SiO}_2\) at 500 K, see Table 1. In Eq. (1), T, \(I_0\), \(I_\lambda\), \(\Gamma _{\lambda }(\vec {q})\), \(\Gamma _{0}\), \(\omega _{\lambda }(\vec {q})\) are free parameters. To account for anharmonic effects such as phonon–phonon interaction that may arise from higher order terms in the Taylor expansion of the interatomic potential, Lorentzian line shapes are used to model the recorded intensity on the detector51. In principle, \(\Gamma _{\lambda }\), the width of the Lorentzian line shape, accounts for the finite lifetime of the vibration mode \(\lambda\). However, this width is expected to be small as anharmonic effects are negligible for temperatures \(k_B T \ll \hbar \omega _m\)51, where \(\omega _m\) is the maximum phonon frequency of the material. In the case of diamond, \(\hbar \omega _m \sim 160\) meV corresponding to a temperature around 1,900 K. Given the resolution of the instrument, no physical information can be extracted from the numerical value of the \(\Gamma _{\lambda }\) obtained from the best fit of the spectra.
Results and discussion
Figure 3 shows the processed, unwrapped, and integrated data from single crystal diamond at room temperature (Fig. 3a–c) and at 500 K (Fig. 3d–f). The vertical dashed lines indicate the edges of the focused image of the analysers on the detector along the dispersive direction (corresponding to the white dashed lines in Fig. 2). The solid black lines correspond to the best fit to the data, within the vertical dashed lines, using the model described above. The fitting procedure is done by minimising the \(\chi ^2\) and is further described in the “Methods” section. In this work, negative energy transfer corresponds to red-shifted photons, and positive energy transfer corresponds to blue-shifted photons.
The best fit parameters for both the cold and hot spectra are summarised in Table 2 (Table 3) for the room temperature (resistively heated) diamond spectrum. It has to be noted that the intensity of the quasi-elastic component in Eq. (1) is given by \(I_0 \Gamma _0\). From the values reported in these tables, one can notice that the quasi-elastic component is negligible in all cases as expected. In addition, the width of the inelastic components, \(\Gamma _{\lambda }\), is on the order of the energy per pixel resolution of the measurement (\(\sim 7.5\) meV per pixel) and corresponds to sub-pixel broadening of the line shape. As a result, no information concerning the phonon lifetime could be extracted from these measurements.
In general, all the phonon branches contribute, with different weights, to the intensity recorded on the detector. However, given the experimental configuration, the longitudinal acoustic mode is the main contributor to the intensity. Along high-symmetry directions, the phonon polarisation vector \(\vec {\epsilon _{\lambda }}\) is either collinear to \(\vec {Q}\) (longitudinal mode) or perpendicular to \(\vec {Q}\) (transverse mode), with \(\vec {Q} = \vec {k}_{out} - \vec {k}_{in}\). The overall intensity \(I_{ \lambda }\), Supplementary Equation S11, is related to the selection rule \(\frac {\vec {Q}\cdot \epsilon _{\lambda }(\vec {q})}{\hbar \omega _{\lambda }}\), from which the only non-zero terms involve the longitudinal acoustic mode. The experimental data presented in Fig. 3 are best explained using a single longitudinal acoustic mode convolved with the instrument resolution.
When comparing the spectra collected at room temperature (Fig. 3a–c) and upon heating (Fig. 3d–f), one can observe a change in the intensity ratio between the red-shifted and the blue-shifted lines. This intensity ratio is related to the temperature of the system through the principle of detailed balance. The measured temperatures are reported in Table 4, and compared directly to temperature as measured by a type K thermocouple attached directly to the target plate (see “Methods” section).
In addition to the change in the amplitude of the red-shifted/blue-shifted lines upon heating, the total number of photons per X-ray pulse scattered by each analyser also increases with temperature, from 0.5 counts per pulse at room temperature to 1.6 counts per pulse at 500 K. This can be understood by considering the dependency of the theoretical expression for the intensity \(I_{\lambda }\) with temperature (See supplemental materials). Since the temperature of the system is low compared to the Debye temperature of diamond (\(\sim 1900\) K)55, the thermal motion of the atoms is still well approximated using a harmonic potential. As a result the energy of the phonon mode, \(\omega _{\lambda }\), is unchanged upon heating and the intensity scales with the Bose–Einstein distribution which is an increasing function of temperature. It has to be noted that the Debye–Waller factor is a decreasing function of temperature. While these two factors have opposite contributions, the Debye–Waller factor is negligible in this case as the measurement was made in the first Brillouin zone (small Q) and on diamond which has a high Debye temperature.
Finally, the energy of the modes \(\hbar \omega _\lambda\) extracted from our experimental measurements are compared with neutron scattering measurements52 and other inelastic X-ray measurements29, and are summarised in Fig. 4. As mentioned above, the side analysers are measuring along an intermediate direction between the [100] and [110]. As a result, the longitudinal acoustic modes corresponding to these two crystallographic directions are shown in Fig. 4. From this figure and the experimental configuration, the measured modes for the central analyser are consistent with the longitudinal acoustic modes of diamond as expected from the experimental design. Finally, to unambiguously determine the position of the modes for the side analysers, one would need to use a better energy resolution.
Conclusions
High resolution (meV) inelastic X-ray scattering on room temperature single crystal (100) diamond and on resistively-heated single crystal (100) diamond up to \(503 \pm 8\) K were performed at the high energy density (HED) instrument at the European XFEL GmbH, Germany using the SASE beam mode. The incoming X-ray beam at 7,492 eV was monochromatised using a combination of a (111) silicon channel cut crystal and a (533) silicon channel cut crystal. The scattered photons at specific reciprocal wave vectors were collected using three spherical diced (533) Si analysers and then focussed on an ePIX100 detector. From the asymmetry of the Stokes and anti-Stokes lines, the sample temperature was measured via the principle of detailed balance. This temperature was then compared with a thermocouple reading with a difference smaller than \(8\%\) for single crystal diamond.
The method was tested on a resistively heated single crystal diamond for which no spatial and temporal gradient of thermodynamic quantities are expected. However, it has been previously reported in the literature that spatial gradients within the material could affect the temperature determination through the use of the principle of detailed balance56,57 and could be an obstacle, if not considered in the experimental design, to the use of this technique for transient states of matter. Several direct improvements are still worth mentioning. The seeded X-ray mode demonstrated at the Linac Coherent Light Source at SLAC National Accelator laboratory, California28,58 and expected in the future at European XFEL would provide a larger number of photons on the sample after the monochromator stage and thus reduce the number of X-ray pulses required to obtain a good quality spectrum. The energy resolution could also be improved by using higher order Bragg reflections for both the high-resolution monochromator and the spherical diced analysers. Finally large plasmas with reduced spatial gradients can be driven using energetic lasers for which this technique could be used59. Such improvements coupled with careful experimental design could offer an accurate temperature measurement for transient states of matter generated by dynamic laser compression and heating techniques which are expected to occur in the near future for instance the high-repetition rate (10 Hz) DiPOLE laser system at the HED instrument at the European XFEL GmbH, Germany.
Methods
Description of the sample heater
A schematic of the assembly used to heat the samples is presented in Fig. 5. The assembly consisted of: (1) a copper sample plate; (2) a copper frame, which was heated by a pair of resistive heater cartridges (McMaster Carr) inserted into the sides of a copper frame; and (3) a water-cooled stainless steel base. Copper was chosen for the material of the heated elements due to its high thermal conductivity and high melting temperature. The sample plate was held against the copper frame by screws, and pressing the sample plate against the copper frame provided sufficient thermal contact for heating. The temperature of the sample plate was measured using a type K thermocouple (Accuglass). Power to the heater cartridges was controlled using a proportional–integral–derivative controller (Fuji Electric) which used a feedback loop to hold the sample plate at the desired temperature. The frame was screwed into the stainless steel water-cooled base with a 1/16-in. piece of MACOR ceramic inserted between them to help thermal isolation. A second thermocouple was placed on the water-cooled base to monitor its temperature. We observed that throughout the whole measurement over the course of several hours, the base plate was maintained at ambient temperature. For room temperature measurements, the heater was turned off and the thermocouple reading was confirmed to be 294 K during the data collection.
Fitting procedure
The fitting procedure is done by minimizing the \(\chi ^2\) error between the experimental data and the model.
Where the summation is carried out over all experimental measurements. \(I^{exp}(\hbar \omega _i)\) is the experimental intensity at energy \(\hbar \omega _i\) and \(I(\hbar \omega _i)\) is the modeled intensity at the same energy. \(\sigma _i\) is the intensity uncertainty at each data point. Since the spectra are constructed by the accumulation of single photons, the intensity at each energy naturally follows as Poisson distribution from which the standard deviation on the intensity can be estimated as \(\sqrt{n_i+1}\) with \(n_i\) the number of photons of energy \(\hbar \omega _i\) collected on the detector.
References
Chen, Y.-K. & Milos, F. S. Ablation and thermal response program for spacecraft heatshield analysis. J. Spacecr. Rockets 36, 475–483. https://doi.org/10.2514/2.3469 (1999).
Guillot, T. Interiors of giant planets inside and outside the solar system. Science 286, 72–77. https://doi.org/10.1126/science.286.5437.72 (1999).
Drake, R. P. Introduction to high-energy-density physics. In High-Energy-Density Physics 1–17 (Springer, Berlin, 2006).
Brown, S. B. et al. Shock drive capabilities of a 30-joule laser at the matter in extreme conditions hutch of the linac coherent light source. Rev. Sci. Instrum. 88, 105113. https://doi.org/10.1063/1.4997756 (2017).
McBride, E. E. et al. Setup for meV-resolution inelastic X-ray scattering measurements at the Matter in Extreme Conditions Endstation at the LCLS. 94550, 1–5. https://doi.org/10.1063/1.5039329 (2018). arXiv:1806.02398.
Kraus, D. et al. Formation of diamonds in laser-compressed hydrocarbons at planetary interior conditions. Nat. Astron. 1, 606–611. https://doi.org/10.1038/s41550-017-0219-9 (2017).
Dorchies, F. et al. Time evolution of electron structure in femtosecond heated warm dense molybdenum. Phys. Rev. B 92, 144201. https://doi.org/10.1103/PhysRevB.92.144201 (2015).
Sperling, P. et al. Free-electron X-ray laser measurements of collisional-damped plasmons in isochorically heated warm dense matter. Phys. Rev. Lett. 115, 115001. https://doi.org/10.1103/PhysRevLett.115.115001 (2015).
Glenzer, S. H. et al. Matter under extreme conditions experiments at the linac coherent light source. J. Phys. B At. Mol. Opt. Phys. 49, 092001. https://doi.org/10.1088/0953-4075/49/9/092001 (2016).
Mason, P. et al. Development of a 100 J 10 Hz laser for compression experiments at the high energy density instrument at the european xfel. High Power Laser Sci. Eng. 6, e65. https://doi.org/10.1017/hpl.2018.56 (2018).
Milathianaki, D. et al. Femtosecond visualization of lattice dynamics in shock-compressed matter. Science 342, 220–223. https://doi.org/10.1126/science.1239566 (2013).
McBride, E. E. et al. Phase transition lowering in dynamically compressed silicon. Nat. Phys. 15, 89–94. https://doi.org/10.2514/2.34691 (2019).
Kraus, D. et al. Nanosecond formation of diamond and lonsdaleite by shock compression of graphite. Nat. Commun. 7, 10970. https://doi.org/10.1038/ncomms10970 (2016).
Wehrenberg, C. E. et al. In situ X-ray diffraction measurement of shock-wave-driven twinning and lattice dynamics. Nature 550, 496–499. https://doi.org/10.1038/nature24061 (2017).
Gleason, A. E. et al. Ultrafast visualization of crystallization and grain growth in shock-compressed SiO2. Nat. Commun. 6, 8191. https://doi.org/10.1038/ncomms9191 (2015).
Gleason, A. E. et al. Compression freezing kinetics of water to ice vii. Phys. Rev. Lett. 119, 025701. https://doi.org/10.2514/2.34695 (2017).
Briggs, R. et al. Ultrafast X-ray diffraction studies of the phase transitions and equation of state of scandium shock compressed to 82 GPa. Phys. Rev. Lett. 118, 025501. https://doi.org/10.1103/PhysRevLett.118.025501 (2017).
Coleman, A. L. et al. Identification of phase transitions and metastability in dynamically compressed antimony using ultrafast X-ray diffraction. Phys. Rev. Lett. 122, 255704. https://doi.org/10.1103/PhysRevLett.122.255704 (2019).
Spaulding, D. K. et al. Evidence for a phase transition in silicate melt at extreme pressure and temperature conditions. Phys. Rev. Lett. 108, 065701. https://doi.org/10.2514/2.34698 (2012).
Millot, M. et al. Experimental evidence for superionic water ice using shock compression. Nat. Phys. 14, 297–302. https://doi.org/10.2514/2.34699 (2018).
Ping, Y. et al. Solid iron compressed up to 560 GPa. Phys. Rev. Lett. 111, 065501. https://doi.org/10.1103/PhysRevLett.111.065501 (2013).
Mo, M. Z. et al. Heterogeneous to homogeneous melting transition visualized with ultrafast electron diffraction. Science 360, 1451–1455. https://doi.org/10.1126/science.286.5437.721 (2018).
Kritcher, A. et al. Probing matter at Gbar pressures at the NIF. High Energy Density Phys. 10, 27–34. https://doi.org/10.1016/j.hedp.2013.11.002 (2014).
Saunders, A. M. et al. X-ray Thomson scattering measurements from hohlraum-driven spheres on the omega laser. Rev. Sci. Instrum. 87, 11E724. https://doi.org/10.1063/1.4962044 (2016).
Fletcher, L. B., Kritcher, A. L., Pak, A., Ma, T., Döppner, T., Fortmann, C., Divol, L., Jones, O. S., Landen, O. L., Scott, H. A., Vorberger, J., Chapman, D. A., Gericke, D. O., Mattern, B. A., Seidler, G. T., Gregori, G., Falcone, R. W. & Glenzer, S. H.. Observations of Continuum Depression in Warm Dense Matter with X-Ray Thomson Scattering. Phys. Rev. Lett. 112(14), 145004 (2014).
Kritcher, A. L., Swift, D. C., Döppner, T., Bachmann, B., Benedict, L. X., Collins, G. W., DuBois, J. L., Elsner, F., Fontaine, G., Gaffney, J. A., Hamel, S., Lazicki, A., Johnson, W. R., Kostinski, N., Kraus, D., MacDonald, M. J., Maddox, B., Martin, M. E., Neumayer, P., Nikroo, A., Nilsen, J., Remington, B. A., Saumon, D., Sterne, P. A., Sweet, W., Correa, A. A., Whitley, R. D., Falcone, R. W. & Glenzer, S. H. A measurement of the equation of state of carbon envelopes of white dwarfs. Nature 584(7819), 51–54 (2020).
Glenzer, S. H. & Redmer, R. X-ray Thomson scattering in high energy density plasmas. Rev. Mod. Phys. 81, 1625–1663. https://doi.org/10.1126/science.286.5437.724 (2009).
Fletcher, L. B. et al. Ultrabright X-ray laser scattering for dynamic warm dense matter physics. Nat. Photonics 9, 274–279. https://doi.org/10.1126/science.286.5437.725 (2015).
Burkel, E. Phonon spectroscopy by inelastic X-ray scattering. Rep. Prog. Phys. 63, 171. https://doi.org/10.1088/0034-4885/63/2/203 (2000).
Baron, A. Q. R. High-Resolution Inelastic X-Ray Scattering I: Context, Spectrometers, Samples, and Superconductors 2131–2212 (Springer, Cham, 2020).
Baron, A. Q. R. High-Resolution Inelastic X-Ray Scattering Part II: Scattering Theory, Harmonic Phonons, and Calculations 2213–2250 (Springer, Cham, 2020).
Krisch, M. & Sette, F. Inelastic X-ray scattering with very high resolution at the ESRF. Crystallogr. Rep. 62, 1–12. https://doi.org/10.1134/S1063774517010096 (2017).
Scopigno, T., Balucani, U., Ruocco, G. & Sette, F. Density fluctuations in molten lithium: inelastic X-ray scattering study. J. Phys. Condens. Matter. 12, 8009–8034. https://doi.org/10.1088/0953-8984/12/37/302 (2000).
Pontecorvo, E. et al. High-frequency longitudinal and transverse dynamics in water. Phys. In Rev. E Stat. Nonlinear Soft Matter Phys. 1–28 (2005). https://doi.org/10.1103/PhysRevE.71.011501.
Monaco, G., Cunsolo, A., Ruocco, G. & Sette, F. Viscoelastic behavior of water in the terahertz-frequency range: an inelastic x-ray scattering study. Phys. Rev. E Stat. Phys. Plasmas Fluids Relat. Interdiscip. Top. 60, 5505–5521. https://doi.org/10.1103/PhysRevE.60.5505 (1999).
Gregori, G. & Gericke, D. O. Low frequency structural dynamics of warm dense matter. Phys. Plasmas 16, 056306. https://doi.org/10.1063/1.49977560 (2009).
Mabey, P. et al. A strong diffusive ion mode in dense ionized matter predicted by langevin dynamics. Nat. Commun. 8, 14125. https://doi.org/10.1038/ncomms14125 (2017).
Klein, M. J. Principle of detailed balance. Phys. Rev. 97, 1446–1447. https://doi.org/10.1063/1.49977562 (1955).
Tschentscher, T. et al. Photon beam transport and scientific instruments at the European XFEL. Appl. Sci. 7, 592. https://doi.org/10.3390/app7060592 (2017).
Abeghyan, S. et al. First operation of the SASE1 undulator system of the European X-ray free-electron laser. J. Synchrotron Radiat. 26, 302–310. https://doi.org/10.1107/S1600577518017125 (2019).
Sinn, H. et al. The SASE1 X-ray beam transport system. J. Synchrotron Radiat. 26, 692–699. https://doi.org/10.1107/S1600577519003461 (2019).
Grünert, J. et al. X-ray photon diagnostics at the European XFEL. J. Synchrotron Radiat. 26, 1422–1431. https://doi.org/10.1107/S1600577519006611 (2019).
Zhao, J. et al. Nuclear resonant scattering at high pressure and high temperature. High Press. Res. 24, 447–457. https://doi.org/10.1080/08957950412331331727 (2004).
Wollenweber, L. et al. High-resolution inelastic X-ray scattering at the high energy density scientific instrument at European XFEL (in preparation).
Decking, W. et al. A mhz-repetition-rate hard X-ray free-electron laser driven by a superconducting linear accelerator. Nat. Photonicshttps://doi.org/10.1038/s41566-020-0607-z (2020).
Huotari, S. et al. Improving the performance of high-resolution X-ray spectrometers with position-sensitive pixel detectors. J. Synchrotron Radiat. 12, 467–472. https://doi.org/10.1107/S0909049505010630 (2005).
Shvyd'ko, Y. Dynamical Theory of X-Ray Diffraction in X-Ray Optics (ed. Rhodes, W. T.) 37–142. https://doi.org/10.1007/978-3-540-40890-1 (Springer-Verlag Berlin Heidelberg, 2004).
Carini, G. A. et al. epix100 camera: use and applications at lcls. AIP Conf. Proc. 1741, 040008. https://doi.org/10.1063/1.4952880 (2016).
Sala, M. M., Martel, K., Henriquet, C., Zein, A. A. & Simonelli, L. Beamlines a high-energy-resolution resonant inelastic X-ray scattering spectrometer at ID20 of the European Synchrotron Radiation Facility. J. Synchrotron Radiat. 25, 580–591. https://doi.org/10.1107/S1600577518001200 (2018).
Squires, G. L. Correlation Functions in Nuclear Scattering 3rd edn, 61–85 (Cambridge University Press, Cambridge, 2012).
Marshall, W. & Lovesey, S. W. Scattering by Phonons 64–93 (Oxford University Press, Oxford, 1971).
Warren, J. L., Yarnell, J. L., Dolling, G. & Cowley, R. A. Lattice dynamics of diamond. Phys. Rev. 158, 805–808. arXiv:1806.023981 (1967).
Burkel, E. Inelastic Scattering of X-rays with Very High Energy Resolution Vol. 125 (Springer, Berlin, 2006).
Schwoerer-Böhning, M., Macrander, A. T. & Arms, D. A. Phonon dispersion of diamond measured by inelastic X-ray scattering. Phys. Rev. Lett. 80, 5572–5575. https://doi.org/10.1103/PhysRevLett.80.5572 (1998).
Desnoyehs, J. E. & Morrison, J. A. The heat capacity of diamond between 12 \(\cdot\) 8 and 277k. Philos. Mag. J. Theor. Exp. Appl. Phys. 3, 42–48. https://doi.org/10.1080/14786435808243223 (1958).
Kozlowski, P. M., Crowley, B. J. B., Gericke, D. O., Regan, S. P. & Gregori, G. Theory of Thomson scattering in inhomogeneous media. Sci. Rep. 6, 24283. https://doi.org/10.1038/srep24283 (2016).
Beuermann, T.-N., Redmer, R. & Bornath, T. “Thomson” scattering from dense inhomogeneous plasmas. Phys. Rev. E 99, 053205. https://doi.org/10.1103/PhysRevE.99.053205 (2019).
Amann, J. et al. Demonstration of self-seeding in a hard-X-ray free-electron laser. Nat. Photonics 6, 693–698. https://doi.org/10.1038/nphoton.2012.180 (2012).
Falcone, R. et al.Workshop Report: Brightest Light Initiative (March 27-9 2019, OSA Headquarters, Washington, D.C.) (2020).
Acknowledgements
We acknowledge funding from the National Science Foundation under Grant No. 163270. This work was supported by the Department of Energy, Laboratory Directed Research and Development program at SLAC National Accelerator Laboratory, under contract DE-AC02-76SF00515 and as part of the Panofsky Fellowship awarded to E.E.M. We acknowledge European XFEL in Schenefeld, Germany, for provision of X-ray free-electron laser beamtime at HED and would like to thank the staff for their assistance. Data recorded at the European XFEL is available at 10.22003/XFEL.EU-DATA-002191-00. JSW acknowledges support from the UK EPSRC under grant number EP/S025065/1. O.H. and O.K acknowledge support from the Oxford Centre for High Energy Density Science (OxCHEDS). We acknowledge Heike Marschner and Berit Marx for the preparation of the high resolution silicon (533) channel cut crystal. This material is partially based upon work supported by the U.S. Department of Energy, Office of Science, Office of Fusion Energy Science under Award Number DE-SC0019268 awarded to T.G.W. K.A. and R.R. acknowledge support from the DFG (FOR 2440).
Author information
Authors and Affiliations
Contributions
These experiments were performed as part of a collaboration headed by U.Z & G.G; A.D, B.O.O, L.B.F, J.B.H, S.H.G, E.E.M conceived the experiment; A.D, B.O.O, K.A, V.C, A.C, J.H.E, S.G, O.H, A.L, O.K, R.L, D.M, C.A.J.P, C.P, T.P, C.S, I.U, L.W, J.S.W, G.G, U.Z & E.E.M conducted the experiment; A.D analysed the data with assistance from B.O.O & E.E.M, and A.D, B.O.O & E.E.M wrote the paper. All authors commented critically on the manuscript.
Corresponding author
Ethics declarations
Competing interests
The authors declare no competing interests.
Additional information
Publisher's note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary information
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Descamps, A., Ofori-Okai, B.K., Appel, K. et al. An approach for the measurement of the bulk temperature of single crystal diamond using an X-ray free electron laser. Sci Rep 10, 14564 (2020). https://doi.org/10.1038/s41598-020-71350-x
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-020-71350-x
This article is cited by
-
Materials under extreme conditions using large X-ray facilities
Nature Reviews Methods Primers (2023)
-
Thermal excitation signals in the inhomogeneous warm dense electron gas
Scientific Reports (2022)
Comments
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.